Inter-Check ICI1000S Series
Cash Register Interface System
Installation/Operation Manual
C1000M-B (1/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
TABLE OF CONTENTS (Continued)
Section
Page
4.8 LOCATION ID SETUP ............................................................................................................18
4.8.1 Location ID Program ..................................................................................................18
4.8.2 Location ID On and Screen Position Set ...................................................................19
4.8.3 Location ID Off ...........................................................................................................19
4.9 CUSTOMER HEADER ...........................................................................................................19
4.10 DIAGNOSTICS .......................................................................................................................19
4.10.1 ProgramTransfer .......................................................................................................20
4.10.2 (DL) Burn-In Test .......................................................................................................20
4.10.3 (DL) Input Channel Port Test .....................................................................................20
4.10.4 Memory Tests ............................................................................................................21
4.10.5 System Signals Test...................................................................................................21
4.10.6 Video Screen Test......................................................................................................21
4.10.7 Graphics Screen Test.................................................................................................21
4.10.8 (DL) Pelco PIM Default Load .....................................................................................22
4.11 ALARM INPUT........................................................................................................................23
4.11.1 Alarm Input On/Off.....................................................................................................23
4.11.2 Alarm Trigger Dwell ....................................................................................................24
4.11.3 Screen Link ................................................................................................................24
4.11.4 Auxiliary Print Link .....................................................................................................24
4.11.5 Alarm Text ..................................................................................................................24
4.12 ALARM PROGRAMMING ......................................................................................................24
4.13 THE NV MEMORY WRITE PROTECT SWITCH ....................................................................25
5.0 TROUBLESHOOTING .....................................................................................................................26
5.1 TROUBLESHOOTING FLOW CHART ...................................................................................27
6.0 SPECIFICATIONS ............................................................................................................................29
7.0 WARRANTY AND REPAIR INFORMATION.....................................................................................29
APPENDIX A. HEXADECIMAL, DECIMAL AND BINARY CONVERSION TABLES .................................30
APPENDIX B. ICI1000PIM SWITCH SETTINGS.......................................................................................33
Pelco Manual C1000M-B (1/96)
iii
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
6
7
8
9
Basic ICI1000S Configuration Wiring Diagram ............................................................................3
ICI1000PIM Wiring Configuration ................................................................................................4
Standard RS-232 Style Wiring Configuration...............................................................................4
Printer Output and Alarm Input Wiring .........................................................................................5
Video Adjustment Locations ........................................................................................................6
Keypad Layout .............................................................................................................................7
Program Transfer Wiring Diagram ..............................................................................................20
Printer Output and Alarm Input Wiring .......................................................................................23
ICI1000PIM Switch Settings ......................................................................................................36
LIST OF TABLES
Table
Page
1
2
3
Data Screen ID ..........................................................................................................................11
Label Descriptors .......................................................................................................................25
ICI1000S Series Pinouts............................................................................................................25
REVISION HISTORY
Manual #
C1000M
Date
Comments
—
Original version.
C1000M-A
11/95
Revised to incorporate Programming Menu Map, Section 4.0,
and Troubleshooting Flow Chart, Section 5.1.
C1000M-B
1/96
Revised to include Appendix B, ICI1000PIM Switch Settings.
iv
Pelco Manual C1000M-B (1/96)
INSTALLATION/OPERATION MANUAL
ICI1000S SERIES INTER-CHECK®
CASH REGISTER INTERFACE SYSTEM
1.0 WARNINGS
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
1. Installation and servicing should only be done by
qualifiedservicepersonnelandconformtoalllocal
codes.
4. OnlyusereplacementpartsrecommendedbyPelco.
5. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
betweenlineandexposedpartstoverifytheexposed
parts have not been connected to line circuitry.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is
designed for indoor use only and it must not be
installed where exposed to rain and moisture.
3. The product and/or manual may bear the following
marks:
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C1000M-B (1/96)
1
2.0 SCOPE
In addition to the high performance and reliability
you’ve come to expect from Pelco products, the Inter-
Check ICI1000S Series offers the following MAIN
FEATURES:
The information contained within this manual covers
the installation and operation of the Inter-Check®
ICI1000S Series cash register interface system.
•
•
•
Monitors one device, cash register or ATM ma-
chine.
Installation should be in accordance with all applicable
local and national electric codes, utilizing approved ma-
terials only.
Exception flagging for special alarm flags such as
VOID or REFUND.
Please familiarize yourself with the information in this
manual prior to installation and operation.
Exception flagging on numerical values such as
price and the manipulation of these values.
2.1 DESCRIPTION
•
•
•
30 separate exceptions can be programmed.
The Inter-Check terminal monitor, or P.O.S., interfaces
with mostATM machines and popular cash registers. It
is compatible with most standard CCTV cameras, video
tape recorders and monitors. The Inter-Check is the heart
of a large family of Pelco products which are designed
to reduce losses in any financial institution.
One programmable alarm output for VCR control.
One programmable alarm input for sensing of any
closure.
•
•
•
•
Completely programmable data channel.
Self-diagnostics to check for proper operation.
Easy on-screen, menu-driven programming.
Non-volatile memory for program storage (no bat-
tery needed).
•
•
•
Horizontal and vertical fine tune controls.
Character size, intensity and video gain controls.
Program transfer function between another Inter-
Check ICI1000S Series unit or Personal Computer
(PC).
•
Program transfer between an Inter-Check ICI1000S
Series and a PC requires special software designed
by Pelco Systems. If interested in this option, con-
tact a Pelco representative.
•
•
Compact 64 function keypad used to program the
Inter-Check ICI1000S Series.
The Inter-Check ICI1000S Series keypad can be
ordered for either external operation or hidden in-
ternal operation. Your choice must be specified
upon the initial order.
2
Pelco Manual C1000M-B (1/96)
3.0 INSTALLATION
NOTE: Do not mount the Inter-Check
ICI1000S Series unit until all connections are
made and programming is complete. Video ad-
justments on the bottom of the Inter-Check
ICI1000S Series may need to be accessible
during the initial set-up.
To begin installation, refer to the following instructions
and Figures 1 and 2.
3.1 INSTALLING INTERFACE CABLE
1. Install interface cable and PIM (if applicable) into
the cash register according to the instructions sup-
plied with your interface cable. Do not power up
PIM .
3.2 BASIC INSTALLATIONS
For basic installations, perform the following steps:
2
Install an 18 gauge, two-conductor shielded cable
between the interface cable/PIM and the ICI1000S
unit using the ICI1000WK (wiring kit) supplied
with your ICI1000S (refer to Figures 2 and 3). This
kit contains two RJ14 phone jacks and one straight-
through six conductor cable.
1. Connect the cable from your video camera to the
BNC labeled “VIDEO IN” on the Inter-Check
ICI1000S (refer to Figure 1). This normally comes
from your camera, splitter, switcher or quad. For
Coaxitron matrix installations, connect the cable
from the desired MONITOR OUTPUT to the BNC
labeled “VIDEO IN” on the Inter-Check unit.
WARNINGS: Do not power up the Inter-
Check ICI1000S Series unit until all other con-
nections have been made.
2. Connect a cable from the BNC labeled “VIDEO
OUT” on the Inter-Check ICI1000S Series to the
video input of your video cassette recorder or
monitor.
Only use the power supply supplied with the Inter-Check
ICI1000S Series unit. Other power supplies may damage
the unit.
Figure 1. Basic ICI1000S Configuration Wiring Diagram
Pelco Manual C1000M-B (1/96)
3
To Inter-Check Unit
To Inter-Check Unit
Straight through
phone cable
Straight through
phone cable
BL
YL
GR
WH
BL
YL
GR
WH
BK
BK
RD
RD
User-supplied cable.
18 AWG shielded wire is
suggested
User-supplied cable.
18 AWG shielded wire is
suggested
From ICI1000PIM
From RS-232 style input
BL
YL
GR
BL
YL
GR
WH
BK
WH
BK
RD
RD
NOTE: For RS-232 style applications only.
Figure 3. Standard RS-232 Style
Figure 2. ICI1000PIM Wiring Configuration
Wiring Configuration
4
Pelco Manual C1000M-B (1/96)
3. Connect the data cable from the register interface
cable (or PIM) to “DATA IN” on the Inter-Check
ICI1000S, using the ICI1000WK and 18 gauge, 2-
conductor shielded cable (see Figure 1).
8. Plug the power supply for the ICI1000PIM into a
120 VAC outlet. The monitor should now display
the register model number.
9. If using the auxiliary print feature, and/or alarm
inputs, follow the wiring diagram in Figure 4 for
proper installation.
4. If using alarms, attach a 22-gauge, 2-conductor
shielded cable from the “ALARM OUT” of the
Inter-Check ICI1000S Series unit to your VCR,
switcher, or other alarmable device.
5. Plug the power supply for the Inter-Check
ICI1000S Series unit into a 120 VAC outlet.
NOTE:The monitor should now show the ini-
tialization message shown below.
6. Use the keypad on top of, or inside, the ICI1000S
chasis to set the standard PIM defaults. Press ENT,
6, 8 and then ESC to return to monitoring mode.
This step is required for all ICI1000S systems (re-
fer to Figure 4).
Pelco
INTER-CHECK/S VER X.X
ROM CHECK = YYYY
CALC. ROM CHECK = YYYY
SYSTEM BEING INITIALIZED!
MM VER. Z.Z
NOTE: ICI1000SI models have an internal
keypad; ICI1000SE models have an external
keypad.
(register model # displayed here)
NOTE: If you do not receive this message,
refer to the troubleshooting guide in Section 5.0.
If your installation does not require the use of
an ICI1000PIM, the register model number will
not appear.
7. Set the dip switches on the front of the ICI1000PIM
to match the setting for your register model num-
ber. Use the ICI1000PIM switch settings located
in the ICI1000PIM manual or Appendix B of this
manual. If your register does not require an
ICI1000PIM, disregard this step.
Alarm
Out
Data
In
13 12 11 10 9 8 7 6 5 4 3 2 1
25 24 23 22 21 20 19 18 17 16 15 14
BL
YL
GR
WH
BK
RD
Alarm
Contact
NOTE: A serial printer used with the Inter-Check ICI1000S
Series must be set at 1200 baud, 8 bits, no parity.
Figure 4. Printer Output and Alarm Input Wiring
Pelco Manual C1000M-B (1/96)
5
3.3 VIDEO ADJUSTMENTS
•
Gain adjusts the entire video screen.Too much gain
will distort the video picture. To reduce video gain,
turn the potentiometer labeled “G” slightly counter-
clockwise.
All video adjustments are located on the bottom of
the Inter-Check unit (refer to Figure 5). Using a non-
metallic screwdriver, make any necessary adjustments
as follows:
•
•
Horizontal Size adjusts the width of the text. To
increase the text width, turn the potentiometer la-
beled “S” slightly clockwise.
•
Horizontal Positioning adjusts the height of the
displayed text. To raise the text position, turn the
potentiometer labeled “H” slightly clockwise. This
adjustment will also correct double-sized charac-
ters appearing on the screen.
Character Size adjusts the size of the characters.
There are four selections. Set the switches marked
“C” in one of the following choices: both up, both
down, first switch up and second one down, or first
switch down and second one up.
•
•
Vertical Positioning adjusts the lateral position of
the displayed text. To move the text to the left, turn
the potentiometer labeled “V” slightly clockwise.
This adjustment will also correct “jittering” text.
Intensity adjusts the brightness of the text. To in-
crease the intensity of the text, turn the potentiom-
eter labeled “I” slightly clockwise.
G
UNLOCKED
LOCKED
V H I
NV MEMORY
SWITCH
S
C
Figure 5. Video Adjustment Locations
6
Pelco Manual C1000M-B (1/96)
4.0 INTER-CHECK ON-BOARD
KEYPAD OPERATION
1. Power down the Inter-Check ICI1000SI unit.
2. Remove the four cover screws with a Phillips
screwdriver and set the cover aside.
The Inter-Check ICI1000S Series features a compact,
64 function keypad used for all programming functions.
Refer to Figure 6. The keypad contains 16 keys. The
four keys on the right side of the keypad are used for
both cursor movement and “shift operations”. The re-
maining keys contain alpha, numeric, and other char-
acters for editing your program. These keys each con-
tain five functions when used with the shift keys.
3. Power up the ICI1000SI unit.
4. Program the Inter-Check unit for your particular
application.
5. When finished programming, replace the cover and
screw down firmly.
To select:
Press:
4.2 THE NV MEMORY WRITE PROTECT
SWITCH
White Character
Color Character
Desired Key
Cursor key of matching color
and then desired key.
Desired arrow key twice.
Enter (ENT)
Your new Inter-Check ICI1000S Series incorporates a
Non-Volatile (NV) type memory. This type of memory
does not require a battery to operate. Refer to Figure 5
for the location of this switch and note the locked and
unlocked positions. This switch must be positioned in
the UNLOCKED position if you intend on program-
ming the Inter-Check ICI1000S Series unit. If the switch
is in the LOCKED position and you try to enter pro-
gramming data, an “ERROR IN WRITING NV
MEMORY!!!” warning will be displayed on the moni-
tor screen. To allow programming, simply position the
write protect switch to the UNLOCKED position. When
programming is complete, position the switch to the
LOCKED position. This will protect your programming
from possible errors that may occur during AC power
fluctuations or complete Inter-Check ICI1000S Series
power loss.
Cursor Movement
Main Menu
Exit Main Menu
Escape (ESC)
4.1 PROGRAMMING THE ICI1000SI
NOTE: Please familiarize yourself with the
information in this manual prior to installation
and operation. Contact the customer's register
dealer/installer prior to installation and opera-
tion. Some warranties and/or service agree-
ments may be affected.
If your Inter-Check unit is an ICI1000SI, it utilizes an
internal keypad for programming all parameters. Fol-
low the steps below prior to programming.
Figure 6. Keypad Layout
Pelco Manual C1000M-B (1/96)
7
ICI1000S PROGRAMMING MENU TREE
Channel Program Menu
Communication Setup Menu
1
1. Communication Setup
2. Data Format/Communica-
tion Protocol
1. Communication Parameters
2. Device Addresses
3. Video Parameters
4. ATM Line Select
System Program Menu
Carriage Return Menu
1. Alarm Outputs
2
2. Carriage Return Control
3. Channel Screen Data
Position
1. Exception Auto CR
2. End Of Line Stop
4. Printer Settings
Monitoring
Mode
5. Exception Alarm Settings
6. Exception Alarm Text Edit
7. Exception Column Line
↵ ENT
Clock Program Menu
1. Set Clock
2. Clock ID On and Screen
Position Set
3. Clock ID Off
4. USA Standard Date
5. European Date
6. Auto Clock Set
Main Program Menu
1
1. Channel 1 Setup
2. System Parameters
3. Clock Setup
4. Location ID Setup
5. Customer Header
6. Diagnostics
2
6
3
4
Location ID Setup Menu
7. Alarm Inputs
1. Location ID Program
2. Location ID on and
Screen Position Set
7
3. Location ID Off
Diagnostics Selection Menu
1. ProgrammTransfer
2. (DL) Burn In Test
3. (DL) Input Channel Port
Test
4. Memory Tests
5. Signals Test
6. Screen Test
7. Graphics Test
8. (DL) PIM Default Load
↵ ENT Key moves Inter-Check
Alarm Input Menu
into the programming
mode from the monitoring
mode
1. Alarm Input On/Off
2. Alarm Trigger Dwell
3. Screen Link
4. Auxiliary Print Link
5. Alarm Text
ESC
Key returns to the
previous menu
Select catagories by
number
8
Pelco Manual C1000M-B (1/96)
4.3 CHANNEL SETUP
NOTE: If the current settings are accept-
able, press the ESC key which returns to the
CHANNEL PROGRAM SELECTION
MENU. If you wish to change the communi-
cation parameters, press “1”. To change the
device addresses press “2”.
There are two ways you can view your current channel
parameters:
1. Press the “1” key on your keypad while in the
monitoring mode.
2. Select CHANNEL SETUP (#1) in the MAIN PRO-
GRAM MENU.
4.3.2 Communication Parameters
This menu enables you to program the data string for-
mat, baud rate, and character set into the Inter-Check
ICI1000S series.
After executing one of these steps, an example of what
you might see is shown below:
SELECTED: CHANNEL
Pelco PIM STANDARD
NOTE: If you do not want to change items
within this menu, simply press ESC. The ESC
key will save the contents on the current line
and bring you to the prompt on the next line.
9600 BAUD,8 BITS,OFF PARITY
NRZ,ASCII,DATA INVERT
DEVICE ADDRESS 1 = 00H 0
DEVICE ADDRESS 2 = 00H 0
NOR. VID,OFF ID.,30 CHARACTERS
18 LINES,DATA DWELL=0
ALARM DWELL : 6/D1
BAUD RATE =?
This prompt enables you to change the baud rate. Enter
the appropriate data and press ENT to save. Use 9600
when connecting to a PIM. Setting the baud to 0 will
turn off the data channel.
EALRM = ON/VP PNTR = OFF
CHANNEL PROGRAM SELECTION MENU
1. COMMUNICATION SETUP
2. DATA FORMAT/COMMUNICATION PROTOCOL
3. VIDEO PARAMETERS
BITS (7 or 8) =?
Enter the appropriate number of data bits by pressing a
7 or 8 on your keypad. Use 8 when connecting to a
PIM.
4.3.1 Communication Setup
This selection allows you to set COMMUNICATION
PARAMETERS and DEVICEADDRESSES. The com-
munication parameters must be programmed correctly
in order for the Inter-Check ICI1000S Series to accept
data from your interface. Device addresses are used pre-
dominantly in ATM programming. Upon entering this
menu, you will notice that the channel’s current COM-
MUNICATION SETUP parameters are displayed as
shown below.
PARITY = 1. ODD, 2. OFF, 3. EVEN
Enter the correct parity configuration of your device
by selecting 1, 2 or 3. Choose #2 for a PIM.
1=NRZ OR 2=NRZI
Choose the appropriate code transmission format by
selecting 1 or 2. NRZ is the most common format. An
exception to this is the SNA/SDLC type of communi-
cations. Select #1 for normal PIM applications.
COMMUNICATION SETUP MENU
SELECTED: 9600 BAUD,8 BITS,OFF PARITY
NRZ,ASCII,DATA INVERTED
DEVICE ADDRESS 1 = 00H 0
DEVICE ADDRESS 2 = 00H 0
1. COMMUNICATION PARAMETERS
2. DEVICE ADDRESSES
Pelco Manual C1000M-B (1/96)
9
1=ASCII OR 2=EBCDIC
Enter the appropriate address as explained above. Af-
ter pressing ESC or entering an address you will be in
the CHANNEL PROGRAM MENU once again. The
current programmed addresses are displayed in both
Hexadecimal and Base 10 formats.
The fifth prompt sets up the character set for the Inter-
Check ICI1000S Series. Press a “1” to select ASCII
and “2” for EBCDIC. The ASCII character set is the
most common whereas EBCDIC is used predominantly
in IBM systems. Select ASCII when connecting to a
Pelco PIM.
NOTE: If you are using SNA or SDLC for-
mats, make both device addresses the same
value.
1=DATA NON INVERT OR 2=DATA INVERT
NOTE: Setting both addresses to 00 puts the
Inter-Check ICI1000S Series unit into diagnos-
tics mode. In this mode the Inter-Check
ICI1000S Series unit will display all network
activity including the proper device address in
your installation.
This prompt sets up the Inter-Check ICI1000S series to
receive either inverted or non-inverted data. This se-
lection varies from one register to the next. Choose
DATA INVERT in PIM applications.
After you have answered all of the prompts, the Inter-
Check ICI1000S Series will show you the changes (if
any) you have made. If the changes are correct, press
ESC. If the changes are incorrect, follow the same steps
just described. Again note that if you do not want to
edit a certain parameter you can skip and save the ini-
tial settings by pressing ESC.
4.4 DATA FORMAT/COMMUNICATION
PROTOCOL
Select this menu by pressing #2 in the CHANNEL
PROGRAM MENU. The menu allows you to choose
the type of device you are connecting to.After pressing
#2 the current settings will be displayed. An example
might be:
4.3.3 Device Addresses
Select this menu by pressing #2 in the Communica-
tion Setup Menu. As mentioned earlier, DEVICEAD-
DRESSES are used in ATM installations. A device
address is the electronic address of the specific ATM
being monitored. The Inter-Check ICI1000S Series
allows you to enter two DEVICE ADDRESSES.
DATA PROTOCOL MENU
SELECTED: PIM STANDARD
To select the proper communication protocol for your
application, use the ENT key or the up and down cur-
sor control keys to scroll through your options. When
you reach the device, save the selection by pressing
ESC.
NOTE:Appendix A illustrates a Hexadeci-
mal to Decimal conversion chart that you may
find helpful. Also, set the unused device ad-
dress to 00H.
Current options include:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PIM STANDARD
PIM GRAPHICS
ICL PRINTER
After pressing #2 the screen will display:
DEVICE ADDRESS -1 3 DECIMAL DIGITS (000-
255) = ?
WAYNE-DRESSER PRINTER
DIEBOLD 910/911 : NCR 751/279
DIEBOLD 910/911 : TC 500/700
DIEBOLD 910/911 : TC 500/700 SYNC
DIEBOLD 910/911 : IBM 3275
DIEBOLD 910/911 : IBM 2260
DIEBOLD 910/911 : IBM 2265
DIEBOLD 910/911 : SNA/SDLC
IBM3624
This prompts you to enter the appropriate address up to
three digits in length. This address must also be be-
tween the specified boundaries, 000-255. If less than
three digits are used, you must press ENT to save. Press-
ing the ESC key will return you to the CHANNEL PRO-
GRAM MENU.
NCR NATIVE MODE
IBM NATIVE MODE
RS232 STANDARD PRINTER
The next prompt reads:
DEVICE ADDRESS -2 3 DECIMAL DIGITS (000-
255) = ?
10
Pelco Manual C1000M-B (1/96)
4.5 VIDEO PARAMETERS
NUMBER OF LINES DISPLAYED (01-18)
To view the video parameters setting press #3 in the
CHANNEL PROGRAM MENU. The Inter-Check
ICI1000S Series will display the current settings. Press-
ing ESC will skip the current line and allow you to con-
tinue in the CHANNEL PROGRAM MENU.
This selection specifies the number of lines you wish
to be displayed. Select the appropriate number of lines
for your application and press enter. The default value
is 18 lines.
DATA DWELL TIME IN SECONDS (000-255)
VIDEO PARAMETER SETUP MENU
SELECTED: NOR VID, OFF ID., 30 CHARACTERS
18 LINES, 0 DATA DWELL
The data dwell time defines the duration of time the
data will stay on the screen. Simply enter the appropri-
ate number of seconds that best suits your needs and
press ENTER. For example, if you want the data to stay
on the screen for 5 seconds after the last line is printed,
press 5 for the data dwell time. The default value is 0
which forces the data “on” at all times.
ENTER DATA OR ESC TO SKIP
REVERSE VIDEO = 1. REV, 2. OFF =?
You may find this feature very useful in bright lighting
conditions. When it is turned on it creates a dark back-
ground around the white text displayed on the monitor.
Reverse video is used for ease in readability. If you
want this feature turned on, press 1. For normal video
presentation press 2.
Example:
A five-second dwell is entered as 005 ENTER
4.6 SYSTEM PARAMETERS
(Selection #2 from the main menu)
4.6.1 Alarm Output
ID. VALUE 0 = OFF, (1-7) = “A” TO “G”
This second prompt enables you to identify the data
screen. This ID will remain on the screen at all times.
For example, you may want to label the data channel
“A” for ease in recognition while viewing the video
tape. This feature is very useful if two Inter-Check
ICI1000S Series are used together on a single VCR and/
or monitor. Refer to Table 1 for a cross-reference. If
you do not wish a screen ID value, press 0 or ESC.
This selection allows you to set the alarming output
features. This output is a normally open closure used to
control external alarmable devices. This output can be-
come active if:
•
•
•
Data is present on the channel.
Exception is met on the data channel.
Closure is seen on the alarming input.
Table 1. Data Screen ID
Selection
Display
The first line in this menu is:
ALARM DWELL : 6/D1
1
2
3
4
5
6
7
A
B
C
D
E
F
(D1 = Data Alarm ON; E1 = Exception Alarm ON)
(I1 = Alarm Input On)
G
This line gives you the current status of the alarming
output. If, for example, the first line of this menu read
“ALARM DWELL : 30/D1E1” the alarm would remain
active for 30 seconds upon the occurrence of either data
or an exception on the data channel. 6/D1 is the default
factory setting.
MAX CHARACTERS PER LINE (01-80)
Selection #3 designates how many characters per line
you want displayed on the monitor. Simply press any
number from 1-80 that best suits your application. De-
fault value is 30.
Pelco Manual C1000M-B (1/96)
11
The next prompt is:
Selecting 1 in this menu turns off the auto carriage re-
turn feature and brings you back to the EXCEPTION
AUTO CR MENU. Selecting 2 in this menu will bring
up the next prompt:
ALARM DWELL TIME IN SECONDS
(001-255)=?
Simply enter in the amount of time you wish the alarm-
ing output to remain active in seconds and press ENT.
CR DWELL TIME IN SECONDS (000-255)=?
At this prompt enter the amount of time in seconds you
wish to wait before the Inter-Check unit automatically
inserts a return. You will then return to the EXCEP-
TION AUTO CR MENU.
The following prompts allow you to activate the alarm-
ing output upon the occurrence of data and/or an ex-
ception on the channel.
CHANNEL DATAALARM ?
1=OFF 2=ON
Entering 2 in the CARRIAGE RETURN MENU will
bring up:
CHANNEL EXCEPTION ALARM ?
1=OFF 2=ON
END OF LINE STOP MENU
STOP
4.6.2 Carriage Return Control
SELECTED: OFF
The carriage return control feature allows you to use
your Inter-Check ICI1000S Series unit with devices that
do not execute a carriage return at the end of the data
lines or a device that has a scrolling message when trans-
actions are not taking place. If a carriage return is not
found at the end of a line, the Inter-Check ICI1000S
Series unit cannot correctly place the text on the screen
or do exceptions on that line. This problem can be solved
with the EXCEPTIONAUTO CR feature of this menu.
The END OF LINE STOP feature allows you to force
the Inter-Check ICI1000S Series to stop its display at
the end of the line when a carriage return is not re-
ceived. This is useful when a device scrolls messages
when transactions are not taking place.
ENTER DATA OR ESC TO SKIP
1=OFF 2=ON
Enter your choice by pressing 1 or 2. You will be brought
back to the CARRIAGE RETURN MENU.
4.6.3 Camera Screen Data Position
This option allows you to position the data anywhere
on the monitor’s screen. When this option is selected a
block of ones (1) is displayed on the monitor which
represents the current size and position of the displayed
data. Move the block by pressing the arrow keys twice
for each increment. After the block has been moved to
the desired position, press ENT to save.
NOTE:The “end of the line” is dependent on
the MAXIMUM CHARACTERS PER LINE
setting in the VIDEO PARAMETERS menu.
4.6.4 Printer Settings
The PRINTER SETTINGS selection allows you to en-
able the auxiliary printer output port and select the data
being sent to the printer. The first thing displayed in
this menu is the current status of the AUX port.
The first prompt in this menu is:
1. EXCEPTION AUTO CR
2. END OF LINE STOP
CHANNEL DATA TO AUX PRINT ?
1=AUX 2=OFF
Entering 1 for EXCEPTION AUTO CR will bring up
the following:
Pressing 1 will send the data received on the channel to
the auxiliary port.
EXCEPTION AUTO CR MENU
EXC. CR
SELECTED: OFF
Pressing 2 will turn off the auxiliary printer port.
CR DWELL:1
ENTER DATA OR ESC TO SKIP
1=OFF 2=ON
NOTE: A serial printer used with the Inter-
Check ICI1000S Series must be set at 1200
baud, 8 bits, no parity.
12
Pelco Manual C1000M-B (1/96)
4.6.5 Exception Alarm Settings
Programming Exceptions
(Selection #5 in the System Program Menu)
NOTE:In order for the Inter-Check ICI1000S
Series to “capture” exception text you must turn
on the EXCEPTIONALARM SETTINGS.An
example is shown below:
EXCEPTIONS are situations of special inter-
est that you can program into your Inter-Check
ICI1000S Series unit. They are used to alarm
your VCR or other alarmable devices when a
certain condition has been met. Exceptions can
also be directly printed to an external printer.
Exception flagging will save you valuable time
reviewing VCR tapes because you have the
ability to view only events of specific interest.
CHANNEL : EALRM = ON / PNTR = ON
ESC TO EXIT OR ENTER TO EDIT?
The above example shows that Channel Exceptions are
turned ON and are being “sent” to an auxiliary printer.
Press ENT to edit; the prompt reads:
Entering the Exception Menu
CHANNEL EXCEPTION FLAG ?
1=OFF 2=ON
To select the Edit Exception Text menu while
in the monitoring mode, follow these steps:
Press 1 to turn channel exceptions OFF or 2 for ON.
Press the ENT key (you will hear one tone).
The MAIN PROGRAM MENU will be dis-
played.
CHANNEL EXCEPTION MARKER VIDEO
PRINT ?
1=OFF 2=ON
MAIN PROGRAM MENU
The Exception Marker Video Print displays asterisks
around an exception appearing on the monitor and/or
printer. It is designed to capture your attention when an
exception has occurred. Press 1 or 2 for your choice.
1. CHANNEL SETUP
2. SYSTEM PARAMETERS
3. CLOCK SETUP
4. LOCATION ID. SETUP
5. CUSTOMER HEADER
6. DIAGNOSTICS
CHANNEL EXCEPTION MARKER AUX.
PRINT ?
1=AUX 2=OFF
7. ALARM INPUTS
This menu is used if you have an external serial printer.
This menu enables you to send data to the auxiliary
output port. If you do not utilize an external printer,
press #2.
Press #2 (you will hear one tone) which cor-
responds to the SYSTEM PARAMETERS
MENU. The following text should appear:
SYSTEM PROGRAM MENU
1. ALARM OUTPUTS
2. CARRIAGE RETURN CONTROL
3. CHANNEL SCREEN DATA
POSITION
4. PRINTER SETTINGS
5. EXCEPTION ALARM SETTINGS
6. EXCEPTION ALARM TEXT EDIT
7. EXCEPTION COLUMN LINE
Pelco Manual C1000M-B (1/96)
13
4.6.6 Exception Alarm Text Edit
ENT
Saves changes to one line in the Text
Editor.
(Selection #6 in the System Program Menu)
DEL
ESC
Deletes a line.
After Pressing #6 the following numbers will appear
across your monitor screen:
Saves any changes made in the edi-
tor and exits back to the SYSTEM
PROGRAM MENU.
12345678901234567890123456789012345678901234567890
= =
(^)
Wildcard or column specific charac-
ter. The caret (^) symbol is displayed
by pressing the right arrow key fol-
lowed by a 6.
This row of numbers is referred to as the Exception
Column Line. This will aid you in programming vari-
ous parameters which will be covered later in this sec-
tion. As mentioned earlier, the Exception Column Line
exactly matches the EXCEPTION COLUMN LINE in
the monitoring mode (when it is turned on).
SPACE
(\)
Inserts position spaces. To insert a
space, press the right arrow key.
The text editor has two prompts; == and =>.
The back-slash (\) is used to describe
a transaction. This symbol is created
by pressing the right arrow key, fol-
lowed by an 8.
The == prompt signifies that the edit mode has not been
entered on that line.You may either edit the line or press
the ENT key to skip.
( )
The “double bar” ( ) is used in price
point formats to define and manipu-
late a string of numbers. This sym-
bol is created by pressing the right
arrow key, followed by a 9.
The => prompt signifies that the edit mode has been
entered on that line. You must view the whole line of
text before you press enter or the line will be deleted.
NOTES: The ENT and the INS key must be
used together to save all changes. If you make
changes within a line, move the cursor to the
end of the line with the RIGHT ARROW key
and press ENT. Pressing the ESC key deletes
all the changes and the text returns to its origi-
nal settings.
NOTE: The next three symbols are used in
conjunction with the “double bar” described
above.
(=)
(<)
Used to identify an equal compari-
son in the price point format.
Unlike the ICI2000D, the ICI1000S automati-
cally converts all text into capital letters for com-
parison purposes. Therefore, when program-
ming exceptions, you do not have to worry
about capital and lower-case designations.
Enables you to flag on values less
than a specified number being de-
fined with the double bar in the price
point format.
(>)
Enables you to flag on values greater
than a specified number being de-
fined with the double bar in the price
point format.
4.6.6.1 Keypad Definitions
Listed below are the various keys you will be using
when programming exceptions on the Inter-Check
ICI1000S Series. Pelco suggests that you become fa-
miliar with the functions before attempting to use the
exception menus.
INS
Saves all changes in Text Editor and
exits back to SYSTEM PROGRAM
MENU. The INS key is also used in
conjunction with the ENT key.
14
Pelco Manual C1000M-B (1/96)
4.6.7 Programming Stratagies
Exceptions Using the COLUMN SPECIFIC
Strategy
Exceptions Using the GLOBAL Strategy
This is used to flag on specific placement of text on
the register ticket. This type of exception uses the (^)
character on your keypad. It is used to capture text ac-
cording to the position on the register ticket. When this
type of exception strategy is used, the Inter-Check
ICI1000S Series searches for specific column place-
ment of data defined by the number of ^ symbols you
use. It may be useful for you to refer to the explana-
tion of the EXCEPTION COLUMN LINE to ensure
proper positioning.
This is used to flag on any text regardless of placement
on the register ticket.
EXAMPLE: Flagging on any VOID within
your system.
You must first enter into the ExceptionAlarm Text Edit
mode. To do this press #2 in the MAIN PROGRAM
MENU (SYSTEM PARAMETERS). Then press #6 in
the SYSTEM PROGRAM MENU (EXCEPTION
ALARM TEXT EDIT).
EXAMPLE: Flagging on department num-
ber 5200 but your register prints it as “ 5200
40.00 “
The display should now read:
123456789012345678901234567890123456789012345678901234567890
= =
1. Turn on the exception column line by pressing se-
lection #7 (EXCEPTION COLUMN LINE) in the
SYSTEMS PARAMETER MENU.
1. Type VOID to match the exact format it is printed
on the register ticket.
2. Press ESC three times to return to the monitoring
mode.
123456789012345678901234567890123456789012345678901234567890
=>VOID
Let’s say the display read:
2. Press ENT to save the exception.
3. Press INS to save the changes.
123456789012345678901234567890123456789012345678901234567890
5200
$40.00
3. Press ENT to access the MAIN MENU.
4. Turn on the EXCEPTION ALARM SETTINGS.
For further instructions, refer to EXCEPTION
ALARM SETTINGS previously described.
4. Press 2 to access the SYSTEMS PARAMETER
MENU.
5. Press ESC three times to resume monitoring.
5. Press 6 to edit exception text.
6. Key in the following:
123456789012345678901234567890123456789012345678901234567890
=>^^^^^5200
7. Press ENT to save the exception.
8. Press INS to save the changes.
9. Press ESC three times to return to the monitoring
mode.
Pelco Manual C1000M-B (1/96)
15
Exception Flagging Using WILDCARDS
The PRICE POINT Exception Flag
Strategy
Used to flag on groups of transactions or departments.
This type of exception also uses the caret (^) character
and is usually used with the COLUMN SPECIFIC type
of exception. Again, it is suggested that you use the
EXCEPTION COLUMN LINE.
The Double Bar character ( ) key enables you to flag
or compare any number that is equal to, greater than,
or less than a desired number.
EXAMPLE: Flagging on any price over
$40.00 in department 52XX and labeling the
exception with a descriptor of JEWELRY DE-
PARTMENT.
EXAMPLE: Flag any transaction in your jew-
elry department where the department number
is 5200-5299. Also, the register prints it out as
“
5250 $40.00 “
1. Select 7 in the SYSTEM PARAMETER MENU.
This turns on the Exception Column Line in the
monitoring mode.
1. Follow steps 1-5 in the previous example.
2. Key in the following:
2. Press ESC three times to return to the monitoring
mode.
123456789012345678901234567890123456789012345678901234567890
=>^^^^^52^^
Let’s say the screen read:
3. Follow steps 7-9 in the previous example.
12345678901234567890123456789012345678901234567890
NOTE: When the ^ key is used as the first
character of exception text, it causes that line
to be Column Specific.Also, when the ^ is pre-
ceded by any other character it will then be read
as a Wildcard character.
5248
$40.00
3. Press ENT.
4. Press 2 to access the SYSTEMS PARAMETER
MENU.
Exception Marking Using the
DESCRIPTOR
5. Press 6 to edit exception text.
6. Key in the following:
The back-slash symbol (\) is used to describe a certain
transaction you are flagging. It is printed on the line
after the exception in the video or printer flag display.
12345678901234567890123456789012345678901234567890
=>^^^^^52^^ 40.00 >\JEWELRY DEPARTMENT
EXAMPLE: Describe the department 5200-
5299 in the above example with a descriptor of
JEWELRY DEPARTMENT.
7. Press ENT to save the exception.
8. Press INS to save the changes and exit.
1. Follow the same programming steps used in the
previous example.
9. Turn on the Exceptions. Do this by pressing #5 in
the SYSTEM PROGRAM MENU and answering
the prompts. For a further explanation on how to
turn on exceptions refer to EXCEPTIONALARM
SETTINGS.
2. Key in the following:
123456789012345678901234567890123456789012345678901234567890
^^^^^52^^\JEWELRY DEPARTMENT
10. Press ESC three times to return to the monitoring
mode.
16
Pelco Manual C1000M-B (1/96)
Notice that the second double bar is placed directly af-
ter the data you are interested in. This format holds true
for any transaction you wish to flag using the double
bar format. The first double bar has a leeway of 15 char-
acters or spaces. In other words, in the previous ex-
ample the first double bar could be placed at 15 spaces
to the left of the 4 in $40.00, but the second double bar
must be inserted directly after the last 0 in $40.00. There-
fore, if your register prints negative numerical values
with a minus sign behind the text and you wish to flag
this type of transaction, you must insert the minus sign
in front (some registers record a refund with a minus
sign). For example, if the above example printed out a
refund of $40.00 as 40.00- you would capture this data
as an exception by programming the Inter-Check
ICI1000S Series in the following format:
4.7 CLOCK SETUP
The Inter-Check unit can be programmed to display
the time and date on the video monitor in any conve-
nient location. The Inter-Check also accepts the USA
or European date structure. The AUTO CLOCK fea-
ture allows the Inter-Check unit to synchronize with
the cash register or ATM machine clock. If the register
or ATM has a clock that is displayed with the data, it is
suggested that the auto clock load feature be used. This
will remove the inaccuracy of using the Inter-Check’s
clock.
NOTE:The internal clock on the Inter-Check
ICI1000S Series is software generated and is
inaccurate.
-40.00 >\JEWELRY DEPARTMENT
4.6.8 Exception Column Line
(Selection #7 in the System Program Menu)
Entering 4 in the main menu will bring up the CLOCK
PROGRAM menu:
CLOCK PROGRAM MENU
1. SET CLOCK
This selection proves to be a valuable tool when edit-
ing exceptions. When this function is turned on, a row
of numbers will appear across the screen in the moni-
toring mode. The row of numbers will exactly match
the row found in the EXCEPTION ALARM TEXT
EDIT menu (explained prior). This function will save
you time when you have a lot of text or multiple spaces
between numbers or characters and are using column
specific exceptions. Examples of this function are also
explained in the following pages.
2. CLOCK ID. ON AND SCREEN POSITION SET
3. CLOCK ID. OFF
4. USA STANDARD DATE
5. EUROPEAN DATE
6. AUTO CLOCK SET
4.7.1 Set Clock
Entering 1 in this menu allows you to set the internal
clock. The following prompt will follow:
YR,MT,DY,HR,MN,SC,DW
XX XX XX XX XX
The cursor will start at the far left hand side and move
to the right as you enter the information. The backspace
key on the keyboard allows you to delete the previous
entry. The arrow keys allow you to move back and forth
without effecting the entered data. The DW position
indicates the day of the week, Sunday being the first
day. The clock uses the 24-hour system (military time)
so the hour is entered as a number from 01 to 24. The
day of the week is entered as a number from 01 to 07.
EXAMPLE: If the day is May 21, 1993 and
the time is 1:40:30 p.m. on a Monday, the fol-
lowing information would be entered:
YR,MT,DY,HR,MN,SC,DW
93 05 21 13 40 30 02
Pelco Manual C1000M-B (1/96)
17
4.7.2 Clock ID On and Screen
Position Set
DATE DELIMITER 1.(/) 2.(-)
Select 1 if the date displayed by the register uses (/) as
a delimiter.
Selection 2 in the CLOCK PROGRAM MENU will
turn the clock on and allow positioning on the screen.
Press the arrow keys twice for each increment to move
the time and date to the preferred position and press
ENT to save.
Select 2 if the date displayed by the register uses (-) as
a delimiter.
TIME DELIMITER 1.(:) 2.(-)
4.7.3 Clock ID Off
Use the same procedure for selecting the time delim-
iter as the date delimiter.
The 3rd selection in the menu will turn off the time and
date video display.
NOTE: The Autoclock Load does not dis-
criminate the seconds position. It will always
load in 30 seconds.
4.7.4 USA Standard Date
Pressing 4 will set the date in the USA standard format
(month, day, year).
4.8 LOCATION ID SETUP
4.7.5 European Date
(Selection #4 from the main menu)
Pressing 5 will set the date in the European standard
format (day, month, year).
The LOCATION ID is normally used to place the name
or location of the user’s store. The ID can be placed
anywhere on the screen and stays resident on the screen
at all times. This feature is useful when one party is
reviewing video tapes from multiple store locations.
4.7.6 Auto Clock Set
Choosing selection 6 in the CLOCK PROGRAM
MENU permits the use of the AUTO CLOCK feature.
In order to use this function, the register’s clock must
be displayed on the monitor by the ICI1000S. Most
registers will display this information. The program-
ming prompt begins:
Pressing 3 in the MAIN PROGRAM MENU will bring
you to the LOCATION ID SETUP menu:
LOCATION ID SETUP MENU
CHANNEL AUTOSET ?
1=OFF 2= ON
1. LOCATION ID PROGRAM
2. LOCATION ID ONAND SCREEN POSITION SET
3. LOCATION ID OFF
Pressing 1 will disable the AUTO CLOCK SET.
Pressing 2 will enable the AUTO CLOCK SET.
4.8.1 Location ID Program
Number 1 in this menu allows you to program the text
for the ID:
12 HOUR MODE LOOK ?
1=OFF 2=ON
ENTER DATAWANTED UPTO 12 CHARACTERS.
Select 1 if the register displays the time in a 24-hour
format.
(ESC) TO SKIP, (ENTER) TO ENTER,
(BS) TO BACKSPACE
Select 2 if the register displays the time in a 12-hour
format.
Enter the text you wish to have displayed, up to 12 char-
acters long, and press ENT to save.
NOTE: If the 12-hour mode is used the Inter-
Check looks for an “A” or a “P” designating
A.M. or P.M. In the 24-hour mode the Inter-
Check loads the time by numerical values.
18
Pelco Manual C1000M-B (1/96)
4.8.2 Location ID On and Screen
Position Set
4.10.1 Program Transfer
The PROGRAM TRANSFER function is used for easy
duplication of the Inter-Check ICI1000S Series program.
This is especially useful for transferring exception pro-
gramming to multiple Inter-Check ICI1000S Series units
within the same chain of stores. Programming can also
be transferred to an IBM compatible PC. This requires a
software program which must be ordered directly from
Pelco. To accomplish a program transfer a simple cable
can either be made or may be ordered from Pelco. Refer
to Figure 7 for proper wiring.
Pressing 2 in the LOCATION ID SETUP MENU will
turn the ID on at all times. It also allows you to posi-
tion the ID with the cursor control keys to the desired
screen display position.
4.8.3 Location ID Off
Pressing 3 will turn off the ID display.
4.9 CUSTOMER HEADER
(Selection #5 from the main menu)
Upon entering 1 in the DIAGNOSTICS MENU the
following prompt appears:
The CUSTOMER HEADER is the message displayed
when the Inter-Check ICI1000S Series is being reset
and initialized. This text may be changed to reflect the
name of the customer’s store or company. Pressing 6 in
the MAIN PROGRAM MENU will allow changing the
customer header:
1. SOURCE 2. DESTINATION
After connecting the cable between the two Inter-Check
units, enter #1 for SOURCE on the Inter-Check ICI1000S
Series that is sending the program. Then enter #2 on the
DESTINATION Inter-Check unit, or the one that is re-
ceiving the program data. The program will then be sent
automatically. Upon detection of an error in transmission,
the system will retry until the proper data is received or
until manually aborted by pressing ESC.
ENTER DATA WANTED UP TO 25 CHARACTERS
(ESC) TO SKIP, (ENTER) TO ENTER,
(BS) TO BACKSPACE
CAUTION: Both units must have the same
memory map version. The memory map is dis-
played upon completion of initialization.
Enter the header desired up to 25 characters in length
and press ENTER to save.
NOTE: Performing a DEFAULTLOAD (DL)
in the Diagnostics Menu will return the cus-
tomer header to the default setting.
MM VER. X.X
4.10.2 (DL) Burn-In Test
4.10 DIAGNOSTICS
(Test performed by Pelco personnel only)
4.10.3 (DL) Input Channel Port Test
(Test performed by Pelco personnel only)
(Selection #6 from the main menu)
WARNING:Some of the tests selected in the
DIAGNOSTICS MENU will cause the pro-
gramming in the Inter-Check ICI1000S Series
unit to be lost. These selections are preceded
by (DL) in the DIAGNOSTIC SELECTION
MENU.
NOTE: Some of the tests in the DIAGNOS-
TICS MENU can only be performed by fac-
tory trained personnel.
Pelco Manual C1000M-B (1/96)
19
Alarm
Out
Alarm
Out
Data
In
Data
In
NOTE: For complete pin-out
information, refer to Table 3.
BL
BK
RD
WH
YL
BL
BK
RD
WH
YL
GR
GR
Figure 7. Program Transfer Wiring Diagram
4.10.4 Memory Tests
NOTE: If the Inter-Check ICI1000S Series
displays the message “ERRORWRITING NV
MEMORY!!!!!!”, the write protect switch on
the bottom of the Inter-Check ICI1000S Series
unit is in the wrong position for this test. Refer
to Section 4.2 and Figure 5 for an explanation
of this error message.
By entering 4 in this menu the following sub-menu is
displayed:
MEMORY TEST MENU
1. RAM TEST
2. VIDEO RAM TEST
3. (DL) NV MEMORY TEST
4. ROM CRC TEST
Pressing #4 will allow the Inter-Check ICI1000S Se-
ries unit to perform a CRC test on the Read Only
Memory. While this test is running, verify that the ROM
CHECK and the CALC. ROM CHECK numbers match.
If there is an error the system will beep and display the
two different ROM numbers. If a failure occurs, un-
plug and retry.
By selecting 1, the unit will perform a self test on its
Random Access Memory. This test is used to verify
system RAM integrity. The system will display an OK
message if the test passes or an address and data if it
fails. ESC brings the Inter-Check ICI1000S Series back
to the DIAGNOSTICS MENU.
4.10.5 System Signals Test
(Test performed by Pelco personnel only)
4.10.6 Video Screen Test
Selecting 2 in this menu will put the Inter-Check
ICI1000S Series into the VIDEO RAM TEST mode.
The video RAM is verified by a slotted, scrolling dis-
play in the upper left hand corner of the monitor. If an
error is detected an address and data will appear on the
screen. ESC brings the unit back to the DIAGNOS-
TICS MENU.
This test produces normal and reverse video images
covering the entire screen. It is used to verify video
character generation and system control.
4.10.7 Graphics Screen Test
WARNING: When the NON-VOLATILE
MEMORY TEST is selected all programming
is lost.
The number 7 selection in the diagnostics menu is used
to test the video graphics mode available on the Inter-
Check ICI1000S Series unit.
The NV MEMORY TEST, (3rd selection), is used to
verify the NON-VOLATILE MEMORY integrity. The
system will display OK if the test passes. Upon error,
the Inter-Check ICI1000S Series will display an address
and the data that was written into the memory location.
20
Pelco Manual C1000M-B (1/96)
4.10.8 (DL) Pelco PIM Default Load
2. Press #6 (you will hear two tones). The following
text will appear:
The Pelco DEFAULT LOAD should be executed for
the following situations:
DIAGNOSTICS SELECTION MENU
•
•
Before doing any programming of the Inter-Check
ICI1000S Series upon initial installation.
1. PROGRAM TRANSFER
2. (DL) BURN IN TEST
3. (DL) INPUT CHANNEL PORT TEST
4. MEMORY TESTS
After a firmware update has been completed.
5. SYSTEM SIGNAL TEST
6. VIDEO SCREEN TEST
7. GRAPHICS SCREEN TEST
8. (DL) Pelco PIM DEFAULT LOAD
Performing a default load sets up all parameters of the
Inter-Check ICI1000S Series unit to the default settings.
This feature of the Inter-Check ICI1000S Series should
be used in normal PIM installations. After executing a
(DL) the Inter-Check ICI1000S Series communication
parameters are set up to receive data from a PIM. The
Inter-Check ICI1000S Series communication param-
eters are set to the following values:
ESC TO QUIT OR SELECT # TO
PROGRAM
3. Press #8 (you will hear two tones). The Inter-Check
ICI1000S Series will prompt you:
9600 BAUD
8 BITS
DEFAULTS BEING LOADED
OFF PARITY
NRZ
The DIAGNOSTICS SELECTION MENU will be dis-
played again.
ASCII
DATA INVERTED
4. Press the ESC key (you will hear one tone). The
Inter-Check ICI1000S Series unit will return to the
monitoring mode and initialize again.
To execute a (DL), follow these steps:
1. Press ENT while in the monitoring mode (you will
hear one tone). The MAIN PROGRAM MENU
will be displayed.
NOTE: Each time you enter the SYSTEM
MENUS and ESC back into the monitoring
mode, the initialization message will be dis-
played.
MAIN PROGRAM MENU
5. After executing a (DL) Pelco PIM DEFAULT
LOAD, the Inter-Check ICI1000S Series system
parameters are set to the following:
1. CHANNEL SETUP
2. SYSTEM PARAMETERS
3. CLOCK SETUP
4. LOCATION ID. SETUP
5. CUSTOMER HEADER
6. DIAGNOSTICS
•
•
•
•
•
Data channel: set for Pelco PIM STANDARD
Data dwell time: continuous display
Lines displayed: 18 lines
Characters displayed: 30 characters
Alarm output : set for six seconds dwell when data
is received.
Data channel text positioning: column 1
Exception alarm: OFF
Auxiliary ports: OFF
7. ALARM INPUTS
ESC TO QUIT OR SELECT # TO
PROGRAM
•
•
•
•
•
Exceptions: not programmed
Location ID: not programmed
Pelco Manual C1000M-B (1/96)
21
4.11 ALARM INPUT
NOTE: For a complete table of status label
descriptions used in the Inter-Check ICI1000S
Series menu system refer to Table 2.
(Selection #7 from the main menu)
TheALARM INPUT can be connected to any normally
open (open loop) alarm device that can trigger a clo-
sure for at least one-half second. Once an alarm is valid,
the trigger is reset to open and will not detect the next
alarm until timeout. For correct wiring, refer to Figure
8 and Table 3.
4.11.1 Alarm Input On/Off
This selection enables you to turn the ALARM INPUT
on or off. You can also route an ALARM INPUT ex-
ception to the output port (i.e., VCR). After pressing
#1 you will see the following:
After selecting #7, the following text will be displayed:
ALARM IN
ALARM DWELL : 6/D1
1=OFF 2=ON
ALARM IN DWELL : 0/OFF/V1 = =>ALARM
IN
Press one (1) to turn the input off, or two (2) to turn the
input on. The next prompt will read:
ALARM INPUT PROGRAM MENU
1. ALARM INPUT ON/OFF
2. ALARM TRIGGER DWELL
3. SCREEN LINK
TRIGGER ALARM OUT
1=OFF 2=ON
4. AUXILIARY PRINT LINK
5. SCREEN HOMING
6. ALARM TEXT
Select one (1) to not trigger the ALARM OUTPUT on
when an alarm from the input is received. Select two
(2) to trigger the ALARM OUTPUT when an alarm
from the input is received.
Alarm
Out
Data
In
13 12 11 10 9 8 7 6 5 4 3 2 1
25 24 23 22 21 20 19 18 17 16 15 14
WH
BK
BL
YL
GR
RD
Alarm
Contact
NOTE: A serial printer used with the Inter-Check ICI1000S
Series must be set at 1200 baud, 8 bits, no parity.
Figure 8. Printer Output and Alarm Input Wiring
22
Pelco Manual C1000M-B (1/96)
4.11.2 Alarm Trigger Dwell
4.12 Alarm Programming
Selection #2 enables you to program the amount of time
that the ALARM INPUT closure must be present in
order for the Inter-Check ICI1000S Series to recognize
it as a valid alarm condition. To program this option,
simply enter a suitable value between 000-255 seconds
for the minimum duration theALARM INPUT closure
is present. This ensures the Inter-Check ICI1000S Se-
ries unit will recognize it as a valid ALARM. The de-
fault value is set at 6 seconds.
NOTE:In the following examples, underlined
text designates the correct selection.
1. Since you want to turn ALARM INPUT “on”, se-
lect #1 under the ALARM INPUT PROGRAM
MENU.
2. Select #2 to turn this ALARM INPUT “on”
ALARM IN
4.11.3 Screen Link
1=OFF 2=ON
Selection #3 allows you to program the ALARM IN-
PUT TEXT to the video display. The ALARM INPUT
TEXT is surrounded by asterisks when this selection is
turned on. It captures your attention when an ALARM
INPUT condition has occurred. Simply select on or off
to display the text to the video screen.
3. Since you want to “send” the ALARM INPUT to
the ALARM OUTPUT, you have to turn ALARM
OUTPUT “on”. This is done by selecting #2 at the
next prompt:
TRIGGER ALARM OUT
1=OFF 2=ON
4.11.4 Auxiliary Print Link
4. Programming a 10 second closure time is done by
pressing #2 (ALARM TRIGGER DWELL) under
the ALARM INPUT PROGRAM MENU.
This selection allows you to program the auxiliary out-
put to print the alarm text. Select either 1 to turn off the
printer to the alarm text, or select 2 to turn the printer
on.
ALARM DWELL TIME IN SECONDS
(000-255) =?10
4.11.5 Alarm Text
Press 10, the appropriate time period, then ENT to
save.
This last selection displays an associated descriptor to
a specifiedALARM INPUT. The Inter-Check ICI1000S
Series allows you to program 12 characters including
spaces. This text will be displayed on the screen if the
SCREEN LINK is turned on and/or a printer if the
AUXILIARYPRINT LINK is turned on.As mentioned
earlier, the ALARM TEXT is surrounded by asterisks
on the printer or video screen.
5. Now link your ALARM INPUT to screen #1. Do
this by selecting #3 (SCREEN LINK) under the
ALARM INPUT PROGRAM MENU.
SCREEN DISPLAY
1=OFF 2=ON
NOTE: Each time you change any of the pa-
rameters just mentioned, the Inter-Check
ICI1000S Series updates current settings auto-
matically. The current settings can be viewed
by entering the ALARM INPUT PROGRAM
MENU.
Let’s say you want your Inter-Check ICI1000S Series
to activate an alarm condition when a cash register
drawer has been open for 10 seconds. After this alarm
has occurred, you want to print the text “REG. 1 OPEN”
on the screen as well as print this text on a printer via
the auxiliary port. You also wish to capture the action
on VCR tape.
Pelco Manual C1000M-B (1/96)
23
6. Print the ALARM INPUT text via auxiliary port.
Do this by selecting #4 (AUXILIARY PRINT
LINK) in the ALARM INPUT PROGRAM
MENU.
4.13 THE NV MEMORY WRITE
PROTECT SWITCH
Your new Inter-Check ICI1000S Series incorporates a
Non-Volatile (NV) type memory. This type of memory
does not require a battery to operate. Refer to Figure 5
for the location of this switch and note the locked and
unlocked positions. This switch must be positioned in
the UNLOCKED position if you intend on program-
ming the Inter-Check ICI1000S Series unit. If the switch
is in the LOCKED position and you try to enter pro-
gramming data, an “ERROR IN WRITING NV
MEMORY!!!” warning will be displayed on the moni-
tor screen. To allow programming, simply position the
write protect switch to the UNLOCKED position. When
programming is complete, position the switch to the
LOCKED position. This will protect your programming
from possible errors that may occur during AC power
fluctuations or complete Inter-Check ICI1000S Series
power loss.
AUX PRINT
1=OFF 2=ON
7. The descriptor will describe the type of action that
caused the alarm. To program the descriptor “REG.
1 OPEN”, enter #5 (ALARM TEXT) in the
ALARM INPUT PROGRAM MENU.
ENTER DATA WANTED UP TO 12
CHARACTERS.
(ESC) TO SKIP, (ENTER) TO ENTER,
(BS) TO BACKSPACE
ALARM IN
REG.1 OPEN
Press ENTER
8. The final display should look like this forALARM
1 IN:
Table 2. Label Descriptors
Descriptor
Display
ALARM IN DWELL : 10/ON/V1A1
= =>REG. 1 OPEN
Data
Video
D1
V
DESCRIPTION:The alarm input is ON and
is currently being “sent” to both the video and
an auxiliary printer. Alarm occurs after a clo-
sure of 10 SECONDS with a descriptor dis-
playing REG.1 OPEN.
Exception
Auxiliary 1
Printer
E
A1
PNTR
EALRM
Exception Alarm
Table 2 is used to identify the descriptors used through-
out the Inter-Check ICI1000S Series menu system.
Table 3. ICI1000S Series Pinouts
Color Pin #
Description
White
Black
Red
1
2
3
Program download input
Signal ground
RS232 current loop CHANNEL
INPUT
Green
Yellow
Blue
4
5
6
TTL printer output
ICI1000PIM input
Alarm input
24
Pelco Manual C1000M-B (1/96)
5.0 TROUBLESHOOTING
Symptom: Red power indicator light on back of
unit is not lit.
Symptom: System does not receive register data.
1. Make sure power supply is plugged in properly.
2. Make sure outlet is working properly.
1. Power down the PIM, then repower it. If you re-
ceive a display on your monitor with a register
model number, the unit is receiving data from the
PIM.
3. Ensure power supply is good (measure 5 volt out-
put).
2. Make sure the register model matches the number
displayed on the monitor.
4. Ensure that internal fuse is not blown.
3. Make sure the switch settings on your PIM are cor-
rect for your model register.
Symptom: External serial printer not operating
properly.
4. Verify that the communication setup and protocol
is accurate for your model register (non-PIM ap-
plications).
1. Ensure proper wiring to the Inter-Check unit.
2. Set printer parameters at 1200 baud, 8 bits, no par-
ity.
5. Check for proper wiring and hardware connections.
Symptom: ERROR IN NV MEMORY message
appears on the monitor.
6. Refer to DEFAULT LOAD procedures in Section
4.10.8 of this manual.
1. NV MEMORY write protect switch on the bottom
of the unit is in the locked position. Move to other
setting. (Refer to Section 4.2 and Figure 5.)
7. Refer to PIM INSTALLATION procedures sup-
plied with your ICI1000PIM or Appendix B of this
manual.
Symptom: RECEIVE ERROR, PLEASE
CHECK PARAMETERS is dis-
played on monitor.
Symptom: No text is displayed on the monitor.
1. Check camera and monitor connections.
1. Usually an indication of incorrect baud rate.
2. Verify that the Inter-Check’s power supply is con-
nected.
2. Also check protocol selection and communication
parameters.
3. Adjust potentiometers on bottom of the Inter-Check
unit.
Symptom: Inter-Check unit displays strange
character.
1. Check communication parameters and protocol.
2. Make sure baud rate is correct.
Symptom: Text vibrates on the monitor.
1. Adjust Vertical (V) on the bottom of the Inter-
Check unit.
2. Adjust Gain (G) on the bottom of the Inter-Check
unit.
Pelco Manual C1000M-B (1/96)
25
5.1 TROUBLESHOOTING FLOW CHART
26
Pelco Manual C1000M-B (1/96)
6.0 SPECIFICATIONS
MODELS
GENERAL
Ambient Operating
Temperature:
35° to 95°F (12.725° to 35°C)
ICI1000SI
Single register interface with inter-
nal keypad for programming; one (1)
alarm output and thirty (30) program-
mable exceptions
Dimensions:
1.5"H x 4.75"W x 8.75"L
(3.81 cm x 12.07 cm x 22.23 cm)
Weight:
2 lbs (.9 kg)
ICI1000SE
Same as ICI1000SI except with ex-
ternal keypad for programming
Construction:
Steel, black enamel
ELECTRICAL
Connectors:
Video
2 BNC
Input Voltage:
5 VDC ±3%
Alarm Out
One open collector output
Power Supply:
Input
Output
Rating:
NEMA 1
120 VAC @ 15 watts, 60 Hz
5 VDC @ 1 amp
Fuse Protection: 1 amp
Video Inputs:
One 75 ohm NTSC/PAL
Video Outputs: One 75 ohm NTSC/PAL
Alarm Outputs: One open collector output optically
isolated to 3000V
Internal Composite
Synchronization:
Standard
NTSC
Vertical 60 Hz @ 260 µs
Horizontal 15.36 KHz @ 4.38 µs
or
Optional PAL Vertical 50 Hz @ 260 µs
Horizontal 15.36 KHz @ 4.38 µs
Pelco Manual C1000M-B (1/96)
27
7.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
•
•
•
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),
and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 1996, Pelco. All rights reserved.
28
Pelco Manual C1000M-B (1/96)
APPENDIX A. HEXADECIMAL, DECIMAL AND BINARY CONVERSION TABLES
HEX
Decimal
Binary
HEX
Decimal
Binary
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
0
1
2
3
4
5
6
7
00000000
00000001
00000010
00000011
00000100
00000101
00000110
00000111
00001000
00001001
00001010
00001011
00001100
00001101
00001110
00001111
00010000
00010001
00010010
00010011
00010100
00010101
00010110
00010111
00011000
00011001
00011010
00011011
00011100
00011101
00011110
00011111
00100000
00100001
00100010
00100011
00100100
00100101
00100110
00100111
00101000
00101001
00101010
00101011
00101100
00101101
00101110
00101111
00110000
00110001
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
00110010
00110011
00110100
00110101
00110110
00110111
00111000
00111001
00111010
00111011
00111100
00111101
00111110
00111111
01000000
01000001
01000010
01000011
01000100
01000101
01000110
01000111
01001000
01001001
01001010
01001011
01001100
01001101
01001110
01001111
01010000
01010001
01010010
01010011
01010100
01010101
01010110
01010111
01011000
01011001
01011010
01011011
01011100
01011101
01011110
01011111
01100000
01100001
01100010
01100011
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
Pelco Manual C1000M-B (1/96)
29
HEX
Decimal
Binary
HEX
Decimal
Binary
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
01100100
01100101
01100110
01100111
01101000
01101001
01101010
01101011
01101100
01101101
01101110
01101111
01110000
01110001
01110010
01110011
01110100
01110101
01110110
01110111
01111000
01111001
01111010
01111011
01111100
01111101
01111110
01111111
10000000
10000001
10000010
10000011
10000100
10000101
10000110
10000111
10001000
10001001
10001010
10001011
10001100
10001101
10001110
10001111
10010000
10010001
10010010
10010011
10010100
10010101
96
97
98
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
10010110
10010111
10011000
10011001
10011010
10011011
10011100
10011101
10011110
10011111
10100000
10100001
10100010
10100011
10100100
10100101
10100110
10100111
10101000
10101001
10101010
10101011
10101100
10101101
10101110
10101111
10110000
10110001
10110010
10110011
10110100
10110101
10110110
10110111
10111000
10111001
10111010
10111011
10111100
10111101
10111110
10111111
11000000
11000001
11000010
11000011
11000100
11000101
11000110
11000111
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
30
Pelco Manual C1000M-B (1/96)
HEX
Decimal
Binary
HEX
Decimal
Binary
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
11001000
11001001
11001010
11001011
11001100
11001101
11001110
11001111
11010000
11010001
11010010
11010011
11010100
11010101
11010110
11010111
11011000
11011001
11011010
11011011
11011100
11011101
11011110
11011111
11100000
11100001
11100010
11100011
11100100
11100101
11100110
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
11100111
11101000
11101001
11101010
11101011
11101100
11101101
11101110
11101111
11110000
11110001
11110010
11110011
11110100
11110101
11110110
11110111
11111000
11111001
11111010
11111011
11111100
11111101
11111110
11111111
Pelco Manual C1000M-B (1/96)
31
APPENDIX B. ICI1000PIM SWITCH SETTINGS
Switches 4-8 These switches are used to set
Installation instructions for configuring the ICI1000PIM
interface module are provided under separate cover in
manual C1005M-D.
addresses of multiple PIM’s in a
Party-line system (ICI3000P unit).
The address selected normally
coincides with the actual cash
register number. The appropriate
switch settings for corresponding
PIM addresses are shown below.
If for some reason this manual is not readily available,
refer to the following section to configure the switch
settings on the PIM interface module, if applicable to
your installation.
DESCRIPTION
SWITCH #
45678
POLLING PIM ADDRESS
(PIM # )
The following describes the DIP switch settings for
banks #1 and #2 on the ICI1000PIM interface module
(refer to Figure 9).
– – – – –
– – – – +
– – – + –
– – – + +
– – + – –
– – + – +
– – + + –
– – + + +
– + – – –
– + – – +
– + – + –
– + – + +
– + + – –
– + + – +
– + + + –
– + + + +
+ – – – –
+ – – – +
+ – – + –
+ – – + +
+ – + – –
+ – + – +
+ – + + –
+ – + + +
+ + – – –
+ + – – +
+ + – + –
+ + – + +
+ + + – –
+ + + – +
+ + + + –
+ + + + +
1
2
3
4
5
6
7
8
SWITCH BANK #1
The switches in this bank serve several different
purposes. Some basic features include Polling or Non-
polling selections, PIM addressing, clock signal
manipulation and ICI1000PIM graphics mode select.
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Switch 1
Switch 2
Selects either a non-inverting or
inverted clock signal. The position
of this switch will vary between
registers. The switch setting varies
depending on the cash register
selected in the register decode list for
SWITCH BANK 2.
Selects either Polling or Non-polling
operation. Polling mode is used only
with the ICI3000P unit (Party-line
configuration) and is defined with a
[–] switch setting. Non-polling mode
should be selected when using Pelco’s
ICI2000D or ICI1000S series products
(stand-alone configuration). This
mode is defined with a [+] switch
setting.
Switch 3
This is a dual function switch
depending on the register type used.
In dot matrix cash register
applications, this switch selects either
NORMAL [–] or PIM GRAPHICS
[+] mode. Other applications will
choose between either receipt or
journal information for monitor
display. Function of this switch are
shown on the page 3. This switch is
normally in the CLOSED [–]
position.
NOTE:
[–] indicates an UP switch position
[+] indicates a DOWN switch position
In other words, a [–] means that you need to
slide the switch towards the [–] position on
the switch. Refer to the Figure 9 for a
definition of [–] and [+] positions.
32
Pelco Manual C1000M-B (1/96)
SWITCH BANK #2
X = POLLING/NON-POLLING
[+] NON-POLLING
This switch is dedicated to selecting which type of cash
register the ICI1000PIM is interfacing with. The table
below indicates the appropriate switch settings for a
particular cash register. The first three settings indicate
the appropriate settings for switches 1-3 on switch bank
#1. A more detailed description of these three switches
can be found at the beginning of this section.
[–] POLLING (Refer to page 35.)
R = RECEIPT
[–] or JOURNAL
[+] SELECT (Normally CLOSED [–])
G = GRAPHICS (Normally CLOSED [–])
+ = OPEN - FLIP THE SWITCH DOWN
IMPORTANT : The information below ap-
plies to the ICI1000PIM versions 4.02 and
greater only.
– = CLOSED - FLIP THE SWITCH UP
Register
Type
Selection
Bank #1
Switch #
1 2 3
Bank #2
Switch #
1 2 3 4 5 6 7 8
CASIO TK-2000 Dot Matrix Printer .................................................................................. + X G
CASIO TK4300 Dot Matrix Printer ................................................................................... + X G
CASIO TK1200/TK2600/TK4600/CE4115/CE4630 Dot Matrix Printer ............................ + X G
CASIO TK2100/CE4530 Dot Matrix Printer ..................................................................... + X G
CASIO SA2000/2100 - Serial Printer ................................................................................ + X -
- - - + + + - -
- - - + + + + -
- - - + + - + +
- - - + + + - +
- - - + + + + +
DATA CHECKER ALPHA 2/3 Printer, ICL MT20001 With Alpha 2/3 Printer....................+ X R
DRESSER WAYNE Printer Serial .....................................................................................+ X R
+ - - + - - + -
+ - - - + + + -
ESPER 7100 Drum Printer................................................................................................ + X -
ESPER 7540/7810 Dot Matrix Printer .............................................................................. + X G
+ - - + + - - -
+ - - + + - - +
FUGITSU/ATRIUM Series with Bar 200 Printer ................................................................+ X R
GILBARCO TCR/G2 Parallel Printer ................................................................................. - X G
HUGEN SWEDA - SWEDA 5436 Serial Printer ................................................................ + X -
+ - - + - - - -
- - - - - - - -
+ - - - - + - -
IBM Model 1/2 Printer, IBM4683/4684 With Model 1 OR Model 2 Printer ........................+ X R
IBM Model 3&4 Printer, IBM4683/4684 IBM4693/4694 With Model 3 Printer...................+ X R
+ - - + - - + +
+ - - + - + - -
ICL-200 PTR, ICL-STORE MASTER 9518-200 ................................................................+ X R
ICL/DATA CHECKER MDL - 1600,1700,1800 Multidrop Connection............................... + X -
ICL/DTS 2000/2100/2200 EPSON 220-AF Dot Matrix Printer ........................................ + X G
ICL/DTS 2000/2100/2200 EPSON 220-F Dot Matrix Printer ........................................... + X G
+ - - + - - - -
+ - - + - - - +
- - + - - - - -
- - + - - - - +
JCM GOLD 2200 Drum Printer ......................................................................................... + X -
+ - - + - + + -
NCR 2127 With V3 MULTIFINCITON Printer - Serial ....................................................... + X -
NCR 2121 Printer - Serial ................................................................................................. + X +
NCR 2113 Printer - Serial ................................................................................................. + X -
NCR ANSWER Printer SINGLE
- - - + + - + -
- - - + + - - +
- - - + + - - -
NCR 1255/2140/2151/2152/2154/2157/2160/2552/2557
NCR 5300/SASI 1028/OLD STYLE Printer/MERIT REGISTER SYSTEMS ................. - X R
NCR ANSWER Printer DUAL - NCR 2126 ....................................................................... - X R
NCR 7150-5001 Printer (7000 SERIES REG.) .................................................................+ X R
- - - + - + - -
- - - + - + - +
- - - + - + + -
Pelco Manual C1000M-B (1/96)
33
Register
Type
Selection
Bank #1
Switch #
1 2 3
Bank #2
Switch #
1 2 3 4 5 6 7 8
NIXDORF .......................................................................................................................... + X +
+ - - + + + + +
OMRON RS5550/RS5560 Dot Matrix Printer ................................................................... - X G
OMRON 4510, 4541 Dot Matrix Printer .............................................................................- X -
OMRON RS3410 Dot Matrix Printer ................................................................................. - X G
OMRON 4041, 4043 Dot Matrix Printer ............................................................................ + X -
- - + - - - + -
- - + - - - + +
+ - - - - + - +
- - + - - + - -
PANASONIC JS-6500 Dot Matrix Printer.......................................................................... - X G
RCALLEN RC204 Drum Printer ........................................................................................ + X -
SAMSUNG 4900, 4915, 4950 Dot Matrix Printer .............................................................. - XG
SANYO ECR 580,690,720 EPSON 220F Dot Matrix Printer ........................................... + X G
+ - - + + - + +
+ - - + - + + +
- - + - - + + -
+ - - + + - + -
SHARP A430 DP630 Dot Matrix Printer ........................................................................... - X G
SHARP 2381/2391 Drum Printer ...................................................................................... + X +
SHARP 3230/3231/3240/3241/4230/4231 Dot Matrix Printer........................................... - X G
SHARP 3100/3100S/3110/3250/3252/3300/3310/3311 Dot Matrix Printer ...................... - X G
SHARP 4230, 4231 Dot Matrix Printer .............................................................................. - XG
SHARP 2595 Drum Printer ............................................................................................... + X +
SHARP 2385/2386/2395/2396 Drum Printer .................................................................... + X +
SHARP A550 Dot Matrix Printer ...................................................................................... + X G
SHARP 3220 Dot Matrix Printer ........................................................................................ - X G
SHARP 2540/2590/2590S Drum Printer ........................................................................... + X +
- - + - - + - +
- - - - - - + -
- - - - - + - +
- - - - - + + -
+ - + - - - - -
- - - - - + - -
- - - - - - + +
- - - - + - - -
- - - - - + + +
- - - - - - - +
SWEDA 2810/OMRON RS14-30 (USA Type) Drum Printer ............................................. + X +
SWEDA 2810/OMRON RS14-40 (USA Type) Drum Printer ............................................. + X +
SWEDA 2810/OMRON RS14-40 (European Type) Drum Printer..................................... + X +
SWEDA 2820/OMRON XXXX-XX (USA Type) Drum Printer ........................................... + X +
SWEDA 2860 .................................................................................................................... - X G
+ - - - - - - -
+ - - - - - - +
+ - - - - - + -
+ - - - - - + +
+ - - + + + - +
TEC 136/141/191/196 DISPLAY....................................................................................... - X +
TEC 206/216/227/230/290 DISPLAY................................................................................ - X +
TEC 141 Printer Drum Printer ........................................................................................... + X +
TEC 132/145 Drum Printer................................................................................................ + X -
TEC 2200/2300/2600 DPR-610/620 Dot Matrix Printer ................................................... + X G
TEC 2200/2300/2600 DPR-630 Dot Matrix Printer .......................................................... + X G
TEC 2200/2300/2600 DPR-61A Dot Matrix Printer.......................................................... + X G
TEC 1050/1060/1100/1190 DPR-710 Dot Matrix Printer .................................................. - X G
TEC 1050/1060/1100/1190 DPR-730 Dot Matrix Printer .................................................. - X G
TEC 1400/1600/1700/1900/FDS-30 DPR-370/374 Dot Matrix Printer............................. + X G
TEC 1400/1600/1700/1900/FSD-30 DPR-370S Dot Matrix Printer ................................. + X G
TEC FT77 Printer - Serial Interface................................................................................... + X -
- - - - + - - +
- - - - + - + -
- - - - + - + +
+ - - + - + - +
- - - - + + - -
- - - - + + - +
- - - - + + + -
- - - - + + + +
- - - + - - - -
- - - + - - - +
- - - + - - + -
- - - + - - + +
TOKHEIM.......................................................................................................................... - X R
+ - - + + + - -
34
Pelco Manual C1000M-B (1/96)
Figure 9. ICI1000PIM Switch Settings
ICI1000PIM INSTALLATION/
TROUBLESHOOTING GUIDELINES
NOTE: In rare instances when connecting a
PIM directly to an ICI1000S unit is desired
(without the use of a wiring kit), the data cable
will need to be modified.
Listed below are some simple troubleshooting steps at
your disposal. Following these steps will ensure that
your Inter-Check P.O.S. unit is communicating correctly
with your ICI1000PIM module.
To modify the cable:
a. Slit the gray insulation jacket of the data cable
and expose the internal wires.
1. Always execute a PIM DEFAULT LOAD (DL) on
your Inter-Check unit. Pelco suggests the use of
the Default Load even if your installation does not
require a PIM module. The Default Load sets all
Inter-Check communication parameters to the spe-
cific values needed to communicate with your
ICI1000PIM module.
b. Cut the red and green wires and remove a
small section of each to prevent against acci-
dental contact.
4. Install the PIM into the cash register. Refer to the
installation instructions included with your particu-
lar cash register interface.
2. Select cash register options using the switch banks
on your PIM. Refer to previous pages for more
information.
5. Power-up PIM and look for prompt again.
3. Utilizing the wiring kit, perform a bench test by
connecting the PIM to the Inter-Check unit and then
power up the PIM. Upon power-up, you should
see a prompt scroll across the monitor which
matches your register type. APIM version number
will also be displayed. If this prompt appears on
the monitor, the Inter-Check unit and PIM are com-
municating properly.
6. Power-up cash register and test for proper opera-
tion.
Now, install the wiring kit and connect the PIM
according to the proper wiring shown in Figure 2
and power up the PIM again. If the wiring is cor-
rect, you should see the prompt explained in step
#3.
Pelco Manual C1000M-B (1/96)
35
®
Pelco
3500 Pelco Way, Clovis, CA 93612-5699 (209) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (209) 292-3827
(Product specifications subject to change without notice.)
C1000M-B
36
Pelco Manual C1000M-B (1/96)
|