EH4014/EH4018 Series
Camera Enclosures
Installation/Operation Manual
C430M-E (1/95)
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
REVISION HISTORY
Manual #
Date
11/88
4/90
Comments
C430M
Original version.
C430M
Rev. A. Added EH4014-1/-2, EH4014/BR, EH4014/CH,
EH4014/CP, EH4018-1/-2, and BK4000/BK4024 models. Fig-
ure 2 revised to show current design. Sections 4.2.1 and
4.2.2 revised to include new cable distances and heater kit
installation procedures. Section 7 updated to include addi-
tional hardware.
C430M
9/90
Rev. B. Manual revised to include Section 1.1 for the UL
compliance and listing.
11/90
11/90
Addendum issued for addition of 230 VAC models.
C430M
C430M
Rev. C. Sections 2.1 thru 2.4, 3.0, 4.2, 4.2.1, and Figures 2
and 3 revised to include the addition of 230 VAC models.
8/91
1/93
1/95
Rev. D. Sections 2.3, 2.4 and Figure 3 revised to include
additional mounts; revised voltages, power consumption and
cable distances; and revised wiring diagram for heater/blower.
Addendum issued to include installation instructions for out-
door applications.
C430M-E
Rev. E. Revised to include new heater wattage values as
per ECO #93-185, new component/assembly diagrams with
updated BOM information as per ECO #93-187. Revised to
show the removal of PC board when using blower kits only,
with updated wiring diagrams, as per ECO #93-210. Incor-
porated the use of CAPU0050.00/25 in 24 VDC blower kit
wiring, as per ECO #94-447. Indoor/outdoor installation in-
structions incorporated.
9/95
Parts list updated to show revised number for item 13.
PELCO Manual C430M-E (1/95)
iii
(This page intentionally left blank.)
iv
PELCO Manual C430M-E (1/95)
INSTALLATION/OPERATION MANUAL
EH4014/EH4018 SERIES
CAMERA ENCLOSURES
1.0 WARNINGS
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
4. Only use replacement parts recommended by
PELCO.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
5. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
betweenlineandexposedpartstoverifytheexposed
parts have not been connected to line circuitry.
2. Unless the unit is specifically marked as a NEMA
Type 3-6P enclosure, it is designed for Indoor use
only and it must not be installed where exposed to
rain and moisture.
6. The installation method and materials should be
capable of supporting four (4) times the weight of
the enclosure, pan/tilt, camera, and lens
combination.
3. The product bears the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
PELCO Manual C430M-E (1/95)
1
2.0 SCOPE
3.0 DESCRIPTION
The information contained within this manual covers
the EH4014/EH4018 Series camera enclosures.
The EH4014 and EH4018 light-duty camera enclosures
are designed for use with 2/3" cameras and will ac-
commodate fixed focal length lenses or motorized zoom
lenses with or without auto-iris operation.
The EH4014 and EH4018 have been engineered for
indoor and outdoor use when used in accordance with
the installation instructions of this manual. They are of
contemporary design for indoor applications and are
fully sealed for outdoor applications.
These enclosures have a removable rear cap for easy
access to the slide-out, camera mount, platform. The
adjustable glands on the rear cap allow for easy instal-
lation and adjustments for cables and camera/lens. The
removable front cap allows manual lens adjustments to
be made without removing the camera/lens.
Figure 1. EH4014/EH4018 Dimension Drawing
2
PELCO Manual C430M-E (1/95)
3.1 MODELS
3.2 OPTIONS
AFW4000
EH4014
Enclosure, indoor/outdoor extruded
aluminum construction for 2/3" cam-
eras and fixed focal length lenses up
to 12" long. (UL, CE)
Anti-fogging window
BK4000
Blower kit for EH4014/EH4018, 120
VAC, 4 watts
EH4014-1
EH4014-2
EH4014-3
Same as EH4014 except maximum
camera/lens length is 10.25" and unit
is supplied with 120 VAC heater/
blower. (UL)
BK4024
BK4220
HK4014
Blower kit for EH4014/EH4018, 24
VAC, 3 watts
Blower kit for EH4014/EH4018, 230
VAC, 4.8 watts
Same as EH4014 except maximum
camera/lens length is 10.25" and unit
is supplied with 24 VAC heater/
blower. (UL, CE)
Heater kit for EH4014/EH4018, 120
VAC, 40 watts.Activates ON at 40°F;
OFF at 60°F
Same as EH4014 except maximum
camera/lens length is 10.25" and unit
is supplied with 230 VAC heater/
blower. (CE)
HK4024
HK4220
LK4000
Heater kit for EH4014/EH4018, 24
VAC, 40 watts.Activates ON at 40°F;
OFF at 60°F
Heater kit for EH4014/EH4018, 230
VAC, 30 watts.Activates ON at 40°F;
OFF at 60°F
EH4014/BR
EH4014/CH
EH4014/CP
EH4018
Same as EH4014 with brass-plated
finish.
Same as EH4014 except chrome
plated finish.
Tamper-proof screw kit for EH4000
Series.
Same as EH4014 except copper
plated finish.
SS4014
SS4018
Sun shroud for EH4014
Sun shroud for EH4018
Enclosure, indoor/outdoor extruded
aluminum construction for 2/3" cam-
eras and fixed focal length lenses up
to 16" long. (UL, CE)
EH4018-1
EH4018-2
EH4018-3
Same as EH4018 except maximum
camera/lens length is 14.25" and unit
is supplied with 120 VAC heater/
blower. (UL)
Same as EH4018 except maximum
camera/lens length is 14.25" and unit
is supplied with 24 VAC heater/
blower. (UL, CE)
Same as EH4018 except maximum
camera/lens length is 14.25" and unit
is supplied with 230 VAC heater/
blower. (CE)
NOTE: 230 VAC models are not listed by
Underwriters Laboratories, Inc.
PELCO Manual C430M-E (1/95)
3
3.3 RECOMMENDED CABLE SIZE
The following cable sizes are the minimum recom-
mended for use with the combination of blower/heater/
camera.
CAUTION: When using a single power
source for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining wire gauge.
Power
Model Number
Input Voltage
120 VAC
Consumption
44 watts
Cable Size
Cable Distance
EH4014-1/
EH4018-1
22 Awg
20 Awg
18 Awg
16 Awg
1,013 ft (308.8 m)
1,612 ft (491.3 m)
2,564 ft (781.5 m)
4,070 ft (1,240.5 m)
EH4014-2/
EH4018-2
24 VAC
43 watts
34.8 watts
4 watts
20 Awg
18 Awg
16 Awg
14 Awg
65 ft (19.8 m)
100 ft (30.48m)
165 ft (50.3 m)
265 ft (80.8 m)
EH4014-3/
EH4018-3
230 VAC
120 VAC
24 VAC
20 Awg
18 Awg
16 Awg
14 Awg
7,488 ft (2,282 m)
11,913 ft (3631 m)
18,906 ft (5,763 m)
30,161 ft (9,193 m)
BK4000
BK4024
BK4220
HK4014
HK4024
HK4220
22 Awg
20 Awg
18 Awg
16 Awg
11,152 ft (3,399.1 m)
17,733 ft (5,405.0 m)
28,213 ft (8,599.3 m)
44,776 ft (13,647.7 m)
3 watts
20 Awg
18 Awg
16 Awg
14 Awg
945 ft (288.0 m)
1,500 ft (457.2 m)
2,385 ft (726.9 m)
3,805 ft (1,159.8 m)
230 VAC
120 VAC
24 VAC
4.8 watts
40 watts
40 watts
30 watts
20 Awg
18 Awg
16 Awg
14 Awg
54,289 ft (16,547.5 m)
86,370 ft (26,326 m)
137,075 ft (41,780 m)
218,667 ft (66,650 m)
22 Awg
20 Awg
18 Awg
16 Awg
1,115 ft (339.9 m)
1,770 ft (539.5 m)
2,820 ft (859.5 m)
4,475 ft (1364.0 m)
20 Awg
18 Awg
16 Awg
14 Awg
70 ft (21.3 m)
110 ft (33.5 m)
175 ft (55.3 m)
285 ft (86.9 m)
230 VAC
20 Awg
18 Awg
16 Awg
14 Awg
8,686 ft (2,647 m)
13,819 ft (4,212 m)
21,932 ft (6,685 m)
34,986 ft (10,664 m)
4
PELCO Manual C430M-E (1/95)
3.4 SPECIFICATIONS
MECHANICAL
Camera
Weight:
EH4014
EH4014-1
EH4014-2
EH4014-3
EH4018
4 lbs. 4 oz. (1.91 kg)
5 lbs. (2.25 kg)
5 lbs. (2.25 kg)
5 lbs. (2.25 kg)
5 lbs. (2.25 kg)
Mounting:
Multiple holes on camera sled
EH4018-1
EH4018-2
EH4018-3
5 lbs. 12 oz. (2.59 kg)
5 lbs. 12 oz. (2.59 kg)
5 lbs. 12 oz. (2.59 kg)
Camera Size:
Accommodates camera/lens combi-
nations up to:
5.25" W x 3.50" H x
12.00" L
(EH4014)
(EH4018)
Shipping
Weight:
16.00" L
(EH4014-1/EH4014-2/EH4014-3)
(EH4018-1/EH4018-2/EH4018-3)
10.25" L
14.25" L
EH4014
6 lbs. (2.7 kg)
EH4014-1
EH4014-2
EH4014-3
EH4018
EH4018-1
EH4018-2
EH4018-3
6 lbs. 12 oz. (3.04 kg)
6 lbs. 12 oz. (3.04 kg)
6 lbs. 12 oz. (3.04 kg)
7 lbs. (3.15 kg)
7 lbs. 12 oz. (3.49 kg)
7 lbs. 12 oz. (3.49 kg)
7 lbs. 12 oz. (3.49 kg)
Viewing
Window:
1/8" thick, optically clear, impact re-
sistant Lexan (U.L. 94HB rated).
Viewing area 2.50"H x 3.75"W.
Cable Entry:
Two compression glands on rear cap
GENERAL
Construction:
Extruded aluminum body; injection-
molded ABS black plastic end caps
Finish:
Textured, semigloss beige enamel
(all models except /BR(brass), /CH
(chrome), or /CP (copper)
Dimensions:
See Figure 1
PELCO Manual C430M-E (1/95)
5
4.0 INSTALLATION
8. Replace the two (2) Phillips head screws.
The following hardware is supplied with the enclosure
and can be used to mount the enclosure or the camera/
lens.
IMPORTANT: When reinstalling the front
or rear of the enclosure, make sure the end caps
are firmly seated against the enclosure to in-
sure proper sealing.
Quantity
Item
9. Attach the enclosure to the appropriate mount or
pan/tilt using the instructions provided.
3
3
3
1/4-20 x .500 Hex head screws
1/4 Flat washers
1/4 Split washers
10. If the housing is mounted such that the two mount-
ing holes are facing up, and only one mounting
hole is used, the other hole shall be plugged by a
1/4"-20 bolt to prevent the entrance of water.
4.1 CAMERA/LENS INSTALLATION
To install the camera/lens, perform the following steps:
11. All cables entering the enclosure shall employ a
service loop to prevent the entrance of water.
1. Remove the two (2) Phillips head screws from the
rear cap.
NOTE: If the lens needs to be adjusted after
installation, it is easier to remove the front cap
to make final lens adjustments.
2. Remove the rear cap from the enclosure, pull out
the sled assembly and remove it from the rail.
3. Place the camera/lens on the sled assembly.
NOTE: Position the camera/lens at the for-
ward-most point on the sled, while allowing
clearance between the lens and enclosure win-
dow when the lens is adjusted to its maximum
physical length.
4. Secure the camera/lens to the sled with the 1/4-20
hex head screws provided.
5. Pull the video and power cables through the glands
and attach to the camera. Adjust the glands for a
tight fit around the cables. The cable glands are
designed to be used with a single cable ranging in
size from 0.187" (0.475 cm) to 0.312" (792 cm) in
diameter.
6. Adjust camera focus and iris if necessary.
7. Replace the sled on the rail and slide the assembly
into the enclosure until the cap is securely closed.
6
PELCO Manual C430M-E (1/95)
4.2 HEATER KIT INSTALLATION
4.3 BLOWER KIT INSTALLATION
Refer to Section 2.4, Recommended Cable Size, to de-
termine cable size needed for installation. To install the
heater and/or blower kits perform the following steps
(refer to Figure 2):
To install the BK4000/BK4024, perform the following
steps:
1. Remove the Phillips Head screws from the rear cap
and slide the assembly out from the enclosure.
1. Remove the Phillips head screws from the rear cap
and slide the assembly out from the enclosure.
2. Attach the blower assembly to the rear plate using
two of the self-tapping screws holding the end cap
to the sled.
2. Attach the bracket with the terminal strip and heater
thermostat to the rear plate using two (2) 6-32 self-
tapping screws, mount onto the drilled-out holes.
3. Wire according to the wiring diagram in Figure 3.
3. Install the bracket with the heater pad onto the front
of the sled using the 1/4-20 screw.
NOTE: When used in conjunction with a
heater kit, the blower can be wired into the ter-
minal block on the P.C. Board.
4. Wire according to the wiring diagram in Figure 3.
Figure 2. Heater Bracket and Blower Installation
PELCO Manual C430M-E (1/95)
7
4.4 INSTALLATION PROCEDURES
The following items are supplied in the heater and blower kits.
Quantity
Item
PELCO Part No.
Blower Kit
Heater Kit
1
1
1
4
4
1
1
1
1
2
1
1
1
1
1
1
1
PCB and blower bracket
BK40004000COMP
X
X
X
X
X
X
PCB and thermostat assy (24V/120V) PCB9000300ASSY
PCB and thermostat assy
PCB mounting screws, 6-32 x 3/8
PCB insulating washers
Heater bracket (24V/120V)
Heater bracket (230V)
Heater pad, 120V/40W
Heater pad, 24V/40W
Heater pad, 120V/15W
Heater bracket mounting screw
Fan, 120 VAC, 19 CFM
Fan, 24 VDC, 19 CFM
Resistor for fan, 3K ohm
Bridge Rectifier Diode
Capacitor
PCB9100300ASSY
ZH6-32X.375SPP
ZH200X437X62N
HK40244000COMP
HK2304000COMP
EHWD10087
EHHK10087
HK300010115
ZH1/420X.375SPP
MM750010003
ED210005
RES003.0K10.0
DIOMDA104
24/120 VAC models
230 VAC model
120 VAC model
24 VAC model
230 VAC model
All heater models
120 & 230 VAC models
24 VAC model
230 VAC model
24 VAC model
24 VAC model
CAPU0050.0/25
BK7044002COMP
Component Bracket
24 & 230 VAC models
Input, AC High
Input, AC (neutral)
Ground
Input, AC High
Input, AC (neutral)
Ground
1
2
1
2
3
4
5
6
Cap
3
4
Fan
Fan
5
6
Diode
Bridge
7
7
8
8
Thermostat
9
9
10
Heater
Heater
10
120 VAC Model
24 VAC Model
Input, AC High
Input, AC (neutral)
Ground
1
2
3
4
Fan
5
6
7
Resistor
8
9
Heater
10
Heater/Blower wiring
diagrams using
Heater Kit with PCB.
Heater
230 VAC Model
Butt Splices Provided
Diode Bridge
AC
Cap
120 VAC (BK4000)
24 VAC (BK4024)
Blower Wiring
Installation only.
Resistor
PCB not required.
230 VAC (BK4220)
Figure 3. Heater/Blower Wiring Diagram
8
PELCO Manual C430M-E (1/95)
4.5 SUN SHROUD INSTALLATION
5. Put the cap back on the enclosure and fasten down
with the screws.
The sun shroud protects the enclosure from the direct
rays of the sun and reduces internal temperature by
approximately 10-15°. To install the sun shroud, per-
form the following steps (refer to Figure 4).
NOTE: Be sure the screws are tightened down
to secure the seal between the cap and the en-
closure.
1. Remove the two (2) screws from the front or rear
end cap of the enclosure.
5.0 CARE AND MAINTENANCE
2. Remove the cap.
Regularly scheduled maintenance will help prolong the
operational life and appearance of the equipment. Clean
the window regularly with a mild nonabrasive deter-
gent in water and with a soft cloth to help maintain
picture clarity.
3. Align the guides on the sun shroud with the runner
on the enclosure.
4. Slide the sun shroud until the bottom guides on the
sun shroud meet the opposite end cap.
Figure 4. Sun Shroud Installation
PELCO Manual C430M-E (1/95)
9
6.0 EXPLODED ASSEMBLY DIAGRAM/ PARTS LIST
The following parts list corresponds to the exploded assembly diagram in Figure 5.
Item
Quantity
Description
Part Number
1
2
3
4
5
6
7
2
1
2
2
1
1
1
1
1
1
4
7
4
1
2
2
1
1
2
4
1
Gasket, front/rear (not shown)
Front cap, black
EH400010000
EH400010006
Gland, SL9
EH400010003
EH400010004
EH40004007COMP
EH400010005
Counter nut, GMP-9
Sled bracket
Rear end cap, black
Body, 14" enclosure (EH4014 only)
Body, 18" enclosure (EH4018 only)
Sled (EH4014)
EH40144000COMP
EH40184000COMP
EH40144001COMP
EH40184001COMP
ZH8-32X.500SPP
ZH8-SBTX.500SPP
ZH260X562X65C
EH400010009
8
Sled (EH4018)
9
Screw, 8-32 x .500, pan head, Phil SS
Screw, #8 x 1/2" Type A, Pan, Phil SS
Washer, flat, 3/16 USS spl-size pltd
Window, 4.453"W x 3.031"H x .125" thick (Lexan)
NP gasket 1/8 x 1/8 ft (not shown)
Screw, 1/4-20 x 1/2" hex cad C/S SS (not shown)
Screw, 1/4-20 x 3/8" pan, Phil SS (not shown)
Washer, internal star 1/4" SS (not shown)
Washer, split lock 1/4" SS (not shown)
Screw, 6-32 x 3/8" Type F Phil Pan SS (not shown)
Installation kit, enclosure hardware (not shown)
10
11
12
13
14
15
16
17
18
19
EH110042
ZH1/4-20X.500CH
ZH1/420X.375SPP
ZH1/4LWSIS
ZH1/4LWSSL
ZH6-SFX.375SPP
IK1000
Figure 5. EH4014/EH4018 Exploded Assembly Diagram
10
PELCO Manual C430M-E (1/95)
7.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
•
•
•
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
following:
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800)
289-9100 or (559) 292-1981 to obtain a Repair Authorization number
(RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions
stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
PELCO Manual C430M-E (1/95)
11
®
PELCO
(559) 292-1981 • (800) 289-9100 • FAX (559) 292-3827 or (800) 289-9150
International customers call 1-559-292-1981 or FAX 1-559-348-1120
(Product specifications subject to change without notice.)
12
PELCO Manual C430M-E (1/95)
|