Philips Indoor Furnishings RAMA FRESNEL PC RANGE User Manual |
RAMA FRESNEL & PC RANGE
OPERATION MANUAL
THANK YOU FOR PURCHASING A PHILIPS SELECON LUMINAIRE. WE HAVE DESIGNED THIS
LUMINAIRE TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE, DESIGN AND
ENGINEERING. WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY
YEARS TO COME.
IMPORTANT NOTE: Before discarding the packaging ensure you have the suspension bolt set, colour frame, lamp base
spacers &/or the lamp.
Before operating your new luminaire please read this information to assist you in making maximum use
of your luminaire, its maintenance and care. If you would like further assistance contact your Philips
Selecon dealer or Philips Selecon.
LAMPING YOUR LUMINAIRE
Before lamping – DISCONNECT THE LUMINAIRE FROM THE POWER SUPPLY. Be aware also that the
lamp, luminaire or integrated safety bond may still be hot, so exercise the necessary caution to avoid
burns. These luminaires are not suitable for mounting on a normally flammable surface.
The Philips Selecon Rama range comprises four models: the High Performance
175 Fresnel, High Performance 175 PC, 150 Fresnel and 150 PC. The Philips
Selecon Rama range is designed for use with either the T/29 1200W or T/19 1000W
lamp.
Philips Selecon Rama Fresnel and PC with GX9.5 Lampbase
To facilitate the use of these two lamps which are of different sizes the height of the
GX9.5 lamp base plate is adjustable. The adjustment is by means of positioning 2
lamp base spacers under the lamp base. Without the spacers, the lamp base is
aligned for use with the T/29 1200W lamp.
With the spacers, the lamp base is aligned for use with the 1000W lamp. To make
the adjustment, loosen the two lamp base fastening screws with a screwdriver, and
lift the lamp base up. Slide the two lamp base spacers into place around the lamp base screws, and tighten the
screws. Lamps able to be used in the Rama GX9.5 version are: 1200W – T/29: 1000W – T/11, T/19, CP24,
CP70.
Philips Selecon Rama Fresnel and PC with G22 Lampbase
It is not necessary to adjust the lamp base height with the G22 version of the Rama range. Lamps able to be
used in the Rama G22 version are: CP71 – 1000W. To fit the lamp:
Release the clip fastener and swing down the rear door.
Insert lamp taking care not to touch the quartz envelope with your fingers.
Close door and lock off the fastener.
Version 5: September 2010
© Philips Selecon
All Rights Reserved
YOKE PIVOT ADJUSTMENT
The yoke on the Rama range can be positioned anywhere in the channel that runs the length of the luminaire.
This is useful to achieve the best balance if using a colour changer or other accessory mounted on the front of
the luminaire, or to fit the luminaire in space restricted positions.
The yoke balance point is factory set on the lamp house for normal applications. To move the yoke, loosen the
M8 bolt at the bottom pivot point of the yoke on the right side of the luminaire. Release the tilt locking clamp on
the left side of the luminaire, and slide the yoke to the required position. Check the yoke is evenly positioned on
each side and tighten the M8 bolt, and the tilt locking clamp. To return the yoke to its original balance point,
align the yoke to the balance point marked on the focus reference scale.
PAN AND TILT ADJUSTMENT
Rama 150 Fresnel and PC, Rama 175 Fresnel and PC
To pan your luminaire loosen the yoke nut and bolt holding the hookclamp onto the yoke and adjust the yoke as
required, then retighten the yoke nut and bolt.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired.
Please note that as the handles and integrated safety bond on the Rama range can reach high temperatures
depending on the position or orientation of the luminaire, and that gloves should always be worn when focusing.
Rama 150 FFT Fresnel and PC, Rama 175 FFT HP Fresnel and PC
The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment. To pan your luminaire
turn the pan locker a ¼ turn clockwise and adjust the yoke as required, then turn the pan locker a ¼ turn
anticlockwise to set the position. A pan angle reference scale is provided on the FFT pan assembly to prefocus
the luminaire if desired.
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired.
ACCESSORIES
Suspension Hook Clamp (Order Code: 20HC)
Lens Safety Mesh (Order Code: 20SM6)
Colour Frame – the luminaire is supplied with a colour frame 186 x 190mm. Additional colour frames are
available (Order Code: 20CFRA12).
Barndoor (Order Code: 20BDSF12)
EARTH TEST POINT
There is an earth test point located on the rear housing of the Rama. The earth test point is the silver machine
screw located on the right side of the rear housing, and is indicated by an earth symbol. To test the earth of the
Rama, place the test probe on the silver machine screw, and perform the earth test.
CLEANING
Open the down-swinging door, and clean the lens and/or reflector with a soft lint-free cloth.
This is the only maintenance task, which can be safely carried out by non-approved personnel.
Refer below – Safety & Maintenance note.
SAFETY & MAINTENANCE
Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended
international safety standards. It is your responsibility to maintain this luminaire in good and safe working
condition.
Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked
lens, damaged cables etc. Consult your Philips Selecon distributor for assistance. Only replace damaged parts
with authorised Philips Selecon spares.
N.B. Luminaire Cable – your Philips Selecon luminaire is fitted with a special heat-resistant, flexible cable,
replace with genuine Philips Selecon spare part cable kit only – refer to your Philips Selecon distributor.
(Replacement cables are supplied complete with necessary terminal connectors).
Version 5: September 2010
© Philips Selecon
All Rights Reserved
Cable Conductor colour codes: Brown
Blue
-Phase, Live
-Neutral, Return
Green/ Yellow -Earth
LIMITED WARRANTY
Philips Selecon warrants its products against defects in materials or workmanship. The term
of this warranty is based on the product usage and is from the date of delivery.
Entertainment, Theatre Term = Three Years
Entertainment, Theatre relates to the typical conditions found in a theatre performance venue viz: 4 –
6 hrs per day, six days per week.
This warranty is void in any of the following circumstances: (a) The luminaire has been misused, neglected,
damaged or abused. (b) The luminaire has been improperly installed, operated, repaired or maintained. (c)
The luminaire has been modified. (d) The luminaire has been connected to other equipment with which it is not
compatible. (e) The luminaire has been used or stored in conditions outside its electrical or environmental
specifications. (f) The luminaire has been used for purposes other than for which it was designed. (g) The
luminaire has been used outside its stated specifications and operating parameters.
Correct installation of the luminaire is the owner’s responsibility.
To assert a warranty claim, complete the Philips Selecon Return Authorisation Form (available from Philips
Selecon). Return the luminaire to Philips Selecon or its authorised agent.
If Philips Selecon accepts the warranty claim, Philips Selecon will provide, or arrange for, service, repair or
replacement as Philips Selecon shall determine in its sole discretion. Philips Selecon shall bear the cost of such
service, repair or replacement. However, the owner shall bear the cost of freight and insurance on the
luminaire, both ways. If Philips Selecon does not wish to service, repair or replace the defective luminaire, it
shall refund the purchase price.
Philips Selecon’s sole responsibility is to repair, replace or service a luminaire subject to a valid warranty claim.
Under no circumstance will Philips Selecon be liable for direct, indirect, incidental, special or consequential
costs or damages, including dismantling and re-installation costs, loss of operations or profits, to the maximum
extent permitted by law.
Philips Selecon accepts no liability for personal injury or property damage resulting from failure to heed relevant
operating and safety procedures specified by Philips Selecon or imposed by law.
This is an express warranty. Philips Selecon disclaims any other express or implied warranties, including
warranties of merchantability or fitness for purpose, to the maximum extent permitted by law.
Some jurisdictions do not allow limitations or disclaimers of implied or statutory warranties. Some jurisdictions
do not allow disclaimers or exclusions of consequential or incidental damages. Therefore, the above
disclaimers, limitations and exclusions may not apply in all jurisdictions in which Philips Selecon sells its
luminaires.
This warranty gives the owner specific legal rights. The owner may have other rights or remedies pursuant to
the laws in its territory. Nothing in this limited warranty should be construed as limiting or restricting any other
statutory right or remedy of the owner, except for such limitations or restrictions herein as may be allowed by the
law of the territory.
Philips Selecon has a policy of continual product improvement and specifications are subject to change without
notice.
PHILIPS SELECON DISTRIBUTOR NETWORK
Your Philips Selecon distributor is a theatre professional with a broad knowledge of understanding of
performance requirements. Most can offer you a full service including not only stage lighting equipment but all
your theatre needs including curtains, scenic paint, sound equipment as well as supplies of lamps, filter, gaffer
tape, etc.
The Philips Selecon dealer network is an international group of lighting professionals throughout North America,
Australasia, Asia and Europe.
Manufacturer
Philips Selecon, 19-21 Kawana Street, Northcote, Auckland 0627, New Zealand
Ph: + 64 9 481 0100, Fax: + 64 9 481 0101
Version 5: September 2010
© Philips Selecon
All Rights Reserved
|