902387 - 10-31-01.qxd 2/12/02 3:29 PM Page 1
ESPAÑOL: PÁGINA 13
FRANÇAISE : PAGE 25
Double Insulated
Portable Electric
Screwdrivers
Instruction
manual
Drywall Drivers
Depth Sensing
MODEL 6640 0/4000 RPM
MODEL 6645 0/2500 RPM
Fastener Drivers
Depth Sensing
MODEL 6641 0/2500 RPM
MODEL 6642 0/2000 RPM
IMPORTANT
To learn more about Porter-Cable
visit our website at:
Please make certain that the person who
is to use this equipment carefully reads
and understands these instructions before
starting operations.
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Part No. 902387 - 10-31-01
Copyright © 2001 PORTER-CABLE Corporation
902387 - 10-31-01.qxd 2/12/02 3:29 PM Page 3
2. Dress properly. Do not wear loose clothing or jewelry. Contain long
hair. Keep your hair, clothing, and gloves away from moving parts. Loose
clothes, jewelry, or long hair can be caught in moving parts.
3. Avoid accidental starting. Be sure switch is OFF before plugging in.
Carrying tools with your finger on the switch or plugging in tools that have the
switch ON invites accidents.
4. Remove adjusting keys or wrenches before turning the tool ON. A
wrench or a key that is left attached to a rotating part of the tool may result in
personal injury.
5. Do not overreach. Keep proper footing and balance at all times.
Proper footing and balance enable better control of the tool in unexpected
situations.
6. Use safety equipment. Always wear eye protection. Dust mask, non-
skid safety shoes, hard hat, or hearing protection must be used for
appropriate conditions.
TOOLS USE AND CARE
1. Use clamps or other practical way to secure and support the
workpiece to a stable platform. Holding the work by hand or against your
body is unstable and may lead to loss of control.
2. Do not force tool. Use the correct tool for your application. The
correct tool will do the job better and safer at the rate for which it is designed.
3. Do not use tool if switch does not turn it ON or OFF. A tool that cannot
be controlled with the switch is dangerous and must be repaired.
4. Disconnect the plug from the power source before making any
adjustments, changing accessories, or storing the tool. Such preventive
safety measures reduce the risk of starting the tool accidentally.
5. Store idle tools out of reach of children and other untrained persons.
Tools are dangerous in the hands of untrained users.
6. Maintain tools with care. Keep cutting tools sharp and clean. Properly
maintained tools, with sharp cutting edges are less likely to bind and are
easier to control.
7. Check for misalignment or binding of moving parts, breakage of
parts, and any other condition that may affect the tool’s operation. If
damaged, have the tool serviced before using. Many accidents are caused
by poorly maintained tools.
8. Use only accessories that are recommended by the manufacturer for
your model. Accessories that may be suitable for one tool may become
hazardous when used on another tool.
SERVICE
1. Tool service must be performed only by qualified repair personnel.
Service or maintenance performed by unqualified personnel may result in a
risk of injury.
2. When servicing a tool, use only identical replacement parts. Follow
instructions in the Maintenance Section of this manual. Use of
unauthorized parts or failure to follow Maintenance Instructions may create a
risk of electric shock or injury.
3
902387 - 10-31-01.qxd 2/12/02 3:29 PM Page 4
SPECIFIC SAFETY RULES AND SYMBOLS FOR
SCREWDRIVERS
1. VERIFY direction of rotation of screwdriver is correct for operation to be
performed before starting tool.
2. DO NOT attempt to change direction of rotation while switch is “ON”. To
do so may damage interlock feature built into switch. Be sure switch is “OFF”
and motor has completely stopped.
3. SOME WOOD CONTAINS PRESERVATIVES WHICH CAN BE TOXIC.
Take extra care to prevent inhalation and skin contact when working with
these materials. Request, and follow, any safety information available from
your material supplier.
4.
WARNING: There are certain applications for which this tool was
designed. Porter-Cable strongly recommends that this tool NOT be modified
and/or used for any application other than for which it was designed. If you
have any questions relative to its application DO NOT use the tool until you
have written Porter-Cable and we have advised you.
Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
SYMBOL
DEFINITION
........................ volts
V
A
........................ amperes
........................ hertz
........................ watts
........................ kilowatts
........................ microfarads
........................ liters
Hz
W
kW
µF
l
kg
........................ kilograms
N/cm2 ........................ newtons per square centimeter
Pa
h
min
s
........................ pascals
........................ hours
........................ minutes
........................ seconds
........................ alternating current
3
........................ three-phase alternating current
3N
........................ three-phase alternating current with neutral
........................ direct current
........................ no load
n0
........................ alternating or direct current
........................ Class II Construction
........................ splash-proof construction
........................ watertight construction
…/min ........................ revolutions or reciprocation per minute
REPLACEMENT PARTS
When servicing use only identical replacement parts.
4
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 5
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown on
the specification plate on the tool. Several models, however, are designed for
A.C. current only. Refer to the specification plate on your tool for proper
voltage and current rating.
CAUTION: Do not operate your tool on a current on which the voltage
is not within correct limits. Do not operate tools rated A.C. only on
D.C. current. To do so may seriously damage the tool.
EXTENSION CORD SELECTION
If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found in
this section. This table is based on limiting line voltage drop to 5 volts (10 volts
for 230 volts) at 150% of rated amperes.
If an extension cord is to be used outdoors it must be marked with the suffix
W-A or W following the cord type designation. For example – SJTW-A to
indicate it is acceptable for outdoor use.
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
115V
230V
25 Ft.
50 Ft.
50 Ft.
100 Ft. 150 Ft. 200 Ft. 250 Ft. 300 Ft. 400 Ft. 500 Ft.
100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. 800 Ft. 1000 Ft.
0-2
2-3
18
18
18
18
18
18
18
16
16
16
14
14
18
18
18
18
16
16
14
14
12
12
12
12
18
16
16
14
14
12
12
10
10
10
8
16
14
14
12
12
10
10
8
16
14
12
12
10
10
8
14
12
12
10
10
8
14
12
10
10
8
12
10
10
8
12
10
8
3-4
4-5
8
5-6
8
6
6-8
6
6
6
8-10
10-12
12-14
14-16
16-18
18-20
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
FUNCTIONAL DESCRIPTION
FOREWORD
Porter-Cable screwdrivers are designed to install or remove various sizes and
types of fasteners. The maximum size of which are listed below:
Model 6641 and 6642:
#12 Wood Screws – 1/4" Self-Drilling-Tapping Screws
Models 6640 and 6645:
Commercially available Drywall Screws
ASSEMBLY and OPERATION
TO START AND STOP SCREWDRIVER
CAUTION: MAKE SURE SWITCH IS OFF BEFORE CONNECTING
TOOL TO POWER SOURCE.
5
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 6
1. Make sure power circuit voltage is the same as that shown on the
specification plate of screwdriver. Connect screwdriver to power circuit.
2. Squeeze trigger switch (A), Fig. 1, to start motor, as the trigger switch is
squeezed, the driver speed increases. The screwdriver bit will not rotate until
engaged in a fastener and forward pressure is applied to the tool. To stop
motor, release trigger switch.
3. LOCK BUTTON - A lock button (B), Fig. 1, is provided to keep motor
running without holding the trigger switch ON.
TO LOCK the trigger switch ON, squeeze the trigger as far as it will go, push
in lock button and release trigger.
TO UNLOCK lock button, squeeze trigger and release, leaving lock button free
to spring out.
4. DIRECTION OF ROTATION – PORTER-CABLE screwdrivers will rotate
either in a clockwise direction for driving fasteners with a right hand thread, or
a counter clockwise direction for removing fasteners with a right hand thread.
To determine rotation, stop the motor by releasing the trigger switch and move
the reversing lever (C), Fig. 1, in the direction marked “reverse” for counter-
clockwise rotation, or in the opposite direction for clockwise rotation.
C
A
B
Fig. 1
TO CHANGE HEX NUTSETTER – MODELS 6641, 6642
1. CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
2. Pull the adjusting collar (A), Fig. 2, forward, (away from the power unit),
and rotate collar counterclockwise, to remove the depth stop assembly (B),
Fig. 2, from the clutch housing.
3. Pull nutsetter (C), Fig. 3, straight out. If it is difficult to remove, grip with
pliers and pull.
4. Push selected nutsetter into screwdriver spindle until ball in spindle snaps
into groove in nutsetter shank.
5. Replace depth stop and adjust for depth of drive (see TO ADJUST DEPTH
STOP, MODELS 6641, 6642).
TO ADJUST DEPTH STOP – MODELS 6641, 6642
1. Pull the adjusting collar (A), Fig. 2, forward, (away from power unit), and
hold while performing step 2.
2. Turn adjusting collar until end of depth stop is flush with end of nutsetter.
Do not push in nutsetter as this will engage internal drive.
6
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 7
B
A
Fig. 2
B
C
Fig. 3
3. Release adjusting collar being sure that the depressions in the collar
engage the projections on the clutch housing.
4. Drive a test fastener in a piece of scrap material identical to that to be
used. Examine results of drive and make additional depth stop adjustment if
required as follows:
a) To increase depth of drive, repeat STEP 1 and turn adjusting collar so
that end of nutsetter extends beyond end of depth stop.
b) To decrease depth of drive, repeat STEP 1 and turn adjusting collar so
that end of depth stop extends beyond end of nutsetter.
Each 1/8 turn of the adjusting collar results in .010" change in depth of drive.
5. Repeat STEPS 3 and 4 until desired result is obtained.
C
B
A
D
Fig. 4
7
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 8
TO CHANGE BIT HOLDER – MODELS 6640, 6645
1. CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
2. Twist and pull the aluminum nosepiece (A), Fig. 4, out of the depth stop
assembly.
3. Pull bit holder (B), Fig. 4, straight out. If it is difficult to remove, grip with
pliers and pull. NOTE: Bit (C), Fig. 4, may be removed from bit holder by
pulling straight out.
4. Push new bit holder into spindle until it snaps into place.
5. Install aluminum nose piece and adjust depth stop (see TO ADJUST
DEPTH STOP, MODELS 6640, 6645).
TO ADJUST DEPTH STOP – MODELS 6640, 6645
1. Pull the adjusting collar (D), Fig. 4, forward, (away from power unit), and
hold while performing Step 2.
3
2. Turn depth stop until end of bit extends /32" beyond end of depth stop.
Do not push in nutsetter as this will engage internal drive.
3. Release adjusting collar being sure that the depressions in the collar
engage the projections on the clutch housing.
4. Drive a test fastener in a piece of scrap material identical to that to be
used. Examine results of drive and make additional depth stop adjustment if
required as follows:
a) To increase depth of drive, repeat STEP 1 and turn depth stop so that
end of bit extends further from end of depth stop.
b) To decrease depth of drive, repeat STEP 1 and turn depth stop so that
end of bit is closer to end of depth stop. Each 1/8 turn of the adjusting
collar results in .010" change in depth of drive.
5. Repeat STEPS 3 and 4 until desired result is obtained.
DRIVING DRYWALL SCREWS – MODELS 6640, 6645
1. Install drywall bit and bit holder to screwdriver.
2. Set screwdriver for correct rotation.
3. Start screwdriver and place drywall screw on bit.
CAUTION: DO NOT EXERT PRESSURE ON SCREW WHILE DOING
THIS.
4. Place end of screw in desired location and remove fingers.
5. Apply forward pressure to drive screw until depth stop rests on the
surface of the work. The depth stop should be adjusted so that the fastener
head is sunk just below the surface of the wallboard.
DRIVING SELF-DRILLING/TAPPING SCREWS – MODELS 6640, 6645
These screws drill and tap their own hole as they are driven. This differs from
self-tapping screws in that pre-drilled holes for tapping are not required. Drive
these screws as follows:
1. Install proper nutsetter that fits screw to screwdriver.
2. Set screwdriver for correct rotation.
3. Start screwdriver and insert head of screw in nutsetter.
8
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 9
CAUTION: DO NOT EXERT PRESSURE ON SCREW WHILE DOING THIS.
4. Place end of screw in desired location and remove fingers.
5. Apply forward pressure to drive screw until depth stop rests on the
surface of the work. The depth stop should be adjusted so the fastener head
seats firmly on the work. Avoid seating the fastener too deep to prevent
shearing off the head.
TO REMOVE SCREWS – ALL MODELS
1. Install proper bit that fits screw.
2. Set screwdriver for reverse rotation.
3. Start screwdriver and place bit in screw.
4. Exert forward pressure to remove screw.
MAINTENANCE
KEEP TOOL CLEAN
Periodically blow out all air passages with dry, compressed air. All plastic parts
should be cleaned with soft damp cloth. NEVER use solvents, to clean plastic
parts. They could possibly dissolve or otherwise damage the material.
CAUTION: Wear safety glasses while performing this operation.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord plug
are making good contact in the outlet. Also, check for blown fuses or open
circuit breakers in the line.
CHECK CLUTCH CONDITION
CAUTION: DISCONNECT TOOL FROM POWER SOURCE
Periodically, depending on use, screwdriver clutch jaws should be inspected
for wear. This may be done by removing the screwdriver mechanism housing
(A), Fig. 5, from the power unit.
NOTES: The clutch housing is attached to the power unit with left-
hand threads. The depth stop assembly may be removed from the
clutch housing to expose a set of wrenching “flats” (B), Fig. 5, on the
clutch housing. These “flats” permit the use of a wrench to aid in
clutch housing removal.
B
A
B
Fig. 5
9
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 10
There is a small spring in the end of the power unit spindle shaft. Be
careful not to lose this spring.
Note condition of 3-jaw clutch faces on power unit and screwdriver
mechanism. If they are badly rounded where the angular face meets the top
surface, or appear otherwise worn or faulty, or if the clutch elements are not
securely held in place on their respective shafts by the snap rings, return the
entire tool to your AUTHORIZED PORTER-CABLE SERVICE STATION for
service.
If the jaws are not seriously worn and there are no other apparent faults in the
mechanism, then proceed and be sure that the mechanism and all internal
areas are clean and free of chips or other foreign material and brush a thin
coat of PORTER-CABLE gear lubricant on the clutch elements and
surrounding areas. Reassemble the screwdriver mechanism onto the power
unit. Be sure the spring is on the spindle shaft. NOTE: The housing threads
are left-hand thread.
BRUSH INSPECTION AND LUBRICATION
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA SERVICE
CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
Authorized Porter-Cable Service Station to be thoroughly cleaned and
inspected; worn parts replaced, when necessary; relubricated with fresh
lubricant, if required; reassembled with new brushes; and performance
tested.
Any loss of power before the above maintenance check may indicate the
need for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE
TOOL UNDER THIS CONDITION. If proper operating voltage is present,
return your tool to the Service Station for immediate service.
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due
to wear from normal use. These operations, including brush inspection and
replacement, should ONLY be performed by either an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA SERVICE
CENTER. All repairs made by these agencies are fully guaranteed against
defective material and workmanship. We cannot guarantee repairs made or
attempted by anyone other than these agencies.
Should you have any questions about your tool, feel free to write us at any
time. In any communications, please give all information shown on the
nameplate of your tool (model number, type, serial number, etc.).
10
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 11
ACCESSORIES
A complete line of accessories is available from your Porter-Cable •
Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-
Cable Authorized Service Stations. Please visit our Web Site
www.porter-cable.com for a catalog or for the name of your nearest
supplier.
WARNING: Since accessories other than those offered by Porter-Cable
• Delta, have not been tested with this product use of such accessories
could be hazardous. For safest operation, only Porter-Cable • Delta
recommended accessories should be used with this product.
IMPORTANT NOTE: Size of screwdriver accessories should be
chosen so as not to exceed the specified capacity of driver with
which they are to be used.
11
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 12
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to repair or replacement required
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service
Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied warranty
lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary from
state to state.
12
902387 - 10-31-01.qxd 2/12/02 3:30 PM Page 36
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
ARIZONA
ILLINOIS
MINNESOTA
Cleveland 44125
Tempe 85282 (Phoenix)
2400 West Southern Avenue
Suite 105
Phone: (602) 437-1200
Fax: (602) 437-2200
Addison 60101 (Chicago)
311 Laura Drive
Phone: (630) 628-6100
Fax: (630) 628-0023
Minneapolis 55429
8001 Sweet Valley Drive Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
5522 Lakeland Avenue North
Phone: (763) 561-9080
Fax: (763) 561-0653
OREGON
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
MISSOURI
Portland 97230
CALIFORNIA
North Kansas City 64116
1141 Swift Avenue
P.O. Box 12393
Phone: (816) 221-2070
Fax: (816) 221-2897
4916 NE 122 nd Ave.
Phone: (503) 252-0107
Fax: (503) 252-2123
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
MARYLAND
PENNSYLVANIA
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
Willow Grove 19090
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
St. Louis 63119
7574 Watson Road
Phone: (314) 968-8950
Fax: (314) 968-2790
MASSACHUSETTS
Braintree 02185 (Boston)
719 Granite Street
Phone: (781) 848-9810
Fax: (781) 848-6759
TEXAS
FLORIDA
NEW YORK
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
Houston 77055
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
West 10 Business Center
1008 Wirt Road, Suite 120
Phone: (713) 682-0334
Fax: (713) 682-4867
Tampa 33609
4538 W. Kennedy Boulevard
Phone: (813) 877-9585
Fax: (813) 289-7948
MICHIGAN
WASHINGTON
GEORGIA
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
OHIO
Auburn 98001 (Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
Forest Park 30297 (Atlanta)
5442 Frontage Road, Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
Columbus 43214
4560 Indianola Avenue
Phone: (614) 263-0929
Fax: (614) 263-1238
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts
and accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized
Service Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will
be directed to the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en
muchas grandes ciudades. Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los
accesorios para los productos Porter-Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable
Delta, Centro de Servicio Autorizado o Centro de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas
opciones, llame al 888-848-5175 y le dirigirán al Centro de Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service
agréés sont situés dans beaucoup de grandes villes. Appelez au 800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en
repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-Cable Delta, s’adresser à tout distributeur Porter-Cable
Delta, centre de service agréé ou centre de service d’usine Porter-Cable Delta. Si vous n’avez accès à aucun de ces centres, appeler
le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable Delta le plus proche.
•
•
•
•
•
•
•
•
•
•
•
•
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste,
Québec, Québec
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Montréal), Québec
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 836-2840
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): BAMMER®, LASERLOC®, OMNIJIG®, POCKET CUTTER®,
PORTA-BAND®, PORTA-PLANE®, PORTER-CABLE®, QUICKSAND®, SANDTRAP®, SAW BOSS®, SPEED-BLOC®, SPEEDMATIC®,
SPEEDTRONIC®, STAIR-EASE®, THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, TIGER CUB®, TIGER SAW®, TORQ-BUSTER®,
VERSA-PLANE®, WHISPER SERIES®, DURATRONIC™, FRAME SAW™, INNOVATION THAT WORKS™, JETSTREAM™, MICRO-SET™,
MORTEN™, NETWORK™, RIPTIDE™, TRU-MATCH™, WOODWORKER’S CHOICE™, THE AMERICAN WOOD SHOP™ (design) , AUTO-
SET™, B.O.S.S.™, BUILDER’S SAW™, CONTRACTOR’S SAW™, DELTA™, DELTACRAFT™, HOMECRAFT™, JET-LOCK™, KICKSTAND™,
THE LUMBER COMPANY™ (design). MICRO-SET™, Q3™, QUICKSET II™, QUICKSET PLUS™, SAFEGUARD II™, SANDING CENTER™,
SIDEKICK™, UNIFENCE™, UNIGUARD™, UNIRIP™, UNISAW™, VERSA-FEEDER™ , TPS™, Emc²™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries.
Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden
estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets d’invention et
marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
Printed in U.S.A.
|