ESPAÑOL: PÁGINA 15
FRANÇAISE : PAGE 29
Instruction
manual
Double Insulated
Routers
MODEL 7536
Consisting of:
MODEL 75361 Base
MODEL 75362 Motor
MODEL 7537
Consisting of:
MODEL 75371 Base
MODEL 75372 Motor
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
To learn more about Porter-Cable
visit our website at:
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Copyright © 2003 Porter-Cable Corporation
Part No. 900314 - 12-05-03
3. Do not expose power tools to rain or wet conditions. Water entering a
power tool will increase the risk of electric shock.
4. Do not abuse the cord. Never use the cord to carry the tools or pull
the plug from an outlet. Keep cord away from heat, oil, sharp edges or
moving parts. Replace damaged cords immediately. Damaged cords
increase the risk of electric shock.
5. When operating a power tool outside, use an outdoor extension
cord marked “W-A” or “W”. These cords are rated for outdoor use and
reduce the risk of electric shock.
PERSONAL SAFETY
1. Stay alert, watch what you are doing, and use common sense when
operating a power tool. Do not use tool while tired or under the
influence of drugs, alcohol, or medication. A moment of inattention while
operating power tools may result in serious personal injury.
2. Dress properly. Do not wear loose clothing or jewelry. Contain long
hair. Keep your hair, clothing, and gloves away from moving parts. Loose
clothes, jewelry, or long hair can be caught in moving parts.
3. Avoid accidental starting. Be sure switch is OFF before plugging in.
Carrying tools with your finger on the switch or plugging in tools that have the
switch ON invites accidents.
4. Remove adjusting keys or wrenches before turning the tool ON. A
wrench or a key that is left attached to a rotating part of the tool may result in
personal injury.
5. Do not overreach. Keep proper footing and balance at all times.
Proper footing and balance enables better control of the tool in unexpected
situations.
6. Use safety equipment. Always wear eye protection. Dust mask, non-
skid safety shoes, hard hat, or hearing protection must be used for
appropriate conditions.
TOOLS USE AND CARE
1. Use clamps or other practical way to secure and support the
workpiece to a stable platform. Holding the work by hand or against your
body is unstable and may lead to loss of control.
2. Do not force tool. Use the correct tool for your application. The
correct tool will do the job better and safer at the rate for which it is
designed.
3. Do not use tool if switch does not turn it ON or OFF. Any tool that
cannot be controlled with the switch is dangerous and must be repaired.
4. Disconnect the plug from the power source before making any
adjustments, changing accessories, or storing the tool. Such preventive
safety measures reduce the risk of starting the tool accidentally.
5. Store idle tools out of reach of children and other untrained persons.
Tools are dangerous in the hands of untrained users.
6. Maintain tools with care. Keep cutting tools sharp and clean.
Properly maintained tools, with sharp cutting edges are less likely to bind and
are easier to control.
7. Check for misalignment or binding of moving parts, breakage of
parts, and any other condition that may affect the tool’s operation. If
damaged, have the tool serviced before using. Many accidents are
caused by poorly maintained tools.
8. Use only accessories that are recommended by the manufacturer
for your model. Accessories that may be suitable for one tool may become
hazardous when used on another tool.
3
SERVICE
1. Tool service must be performed only by qualified repair personnel.
Service or maintenance performed by unqualified personnel could result in a
risk of injury.
2. When servicing a tool, use only identical replacement parts. Follow
instructions in the Maintenance Section of this manual. Use of
unauthorized parts or failure to follow Maintenance Instructions may create a
risk of electric shock or injury.
SPECIFIC RULES AND SYMBOLS
1. HOLD TOOL BY INSULATED GRIPPING SURFACES WHEN
PERFORMING AN OPERATION WHERE THE CUTTING TOOLS MAY
CONTACT HIDDEN WIRING OR ITS OWN CORD. Contact with a “live”
wire will make exposed metal parts of the tool “live” and shock the operator.
2. DISCONNECT TOOL FROM POWER SOURCE before making
adjustments or changing bits.
3. TIGHTEN COLLET NUT securely to prevent the bit from slipping.
4. USE A CLAMP or some other device to hold the workpiece rigidly in
position. and clear the path of the tool of obstructions.
5. PROVIDE CLEARANCE under workpiece for router bit when through-
cutting.
6. CHECK TO SEE THAT THE CORD will not “hang up” during routing
operation.
7. CLEAR THE ROUTER BIT AREA before starting motor.
8. MAINTAIN FIRM GRIP on router to resist starting torque.
9. KEEP HANDS CLEAR OF BIT when motor is running to prevent personal
injury.
10. KEEP CUTTING PRESSURE CONSTANT. Do not overload motor.
11. LET THE MOTOR COME TO A COMPLETE STOP before putting the
tool down.
12. NEVER TOUCH router bits after use. They may be extremely hot.
13. NEVER TIGHTEN COLLET NUT without a bit.
14. DO NOT USE ROUTER BITS with a diameter in excess of 2-1/2" at
RPM above 13,000. Router bits up to 3-1/2" in diameter can be used when
speed control is set for 13,000 RPM or less.
15. ALWAYS KEEP CHIP SHIELD clean and in place.
16. AVOID “CLIMB-CUTTING” (see “Using The Router” section in this
manual). “Climb-cutting” increases the chance for loss of control resulting in
possible personal injury.
17. SOME WOOD CONTAINS PRESERVATIVES WHICH CAN BE TOXIC.
Take extra care to prevent inhalation and skin contact when working with
these materials. Request, and follow, any safety information available from
your material supplier.
18.
There are certain applications for which this tool was
designed. Porter-Cable strongly recommends that this tool NOT be modified
and/or used for any application other than for which it was designed. If you
have any questions relative to its application DO NOT use the tool until you
have written Porter-Cable and we have advised you.
Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
4
SYMBOL
DEFINITION
........................ volts
V
A
........................ amperes
........................ hertz
........................ watts
........................ kilowatts
........................ microfarads
........................ liters
Hz
W
kW
µF
l
kg
........................ kilograms
N/cm2 ........................ newtons per square centimeter
Pa
h
min
s
........................ pascals
........................ hours
........................ minutes
........................ seconds
........................ alternating current
3
........................ three-phase alternating current
3N
........................ three-phase alternating current with neutral
........................ direct current
........................ no load
n0
........................ alternating or direct current
........................ Class II Construction
........................ splash-proof construction
........................ watertight construction
…/min ........................ revolutions or reciprocation per minute
REPLACEMENT PARTS
When servicing use only identical replacement parts.
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown
on the specification plate on the tool. Several models, however, are designed
for A.C. current only. Refer to the specification plate on your tool for proper
voltage and current rating.
Do not operate your tool on a current on which the voltage is
not within correct limits. Do not operate tools rated A.C. only on D.C.
current. To do so may seriously damage the tool.
EXTENSION CORD SELECTION
If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found
in this section. This table is based on limiting line voltage drop to 5 volts (10
volts for 230 volts) at 150% of rated amperes.
5
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
115V
230V
25 Ft.
50 Ft.
50 Ft.
100 Ft. 150 Ft. 200 Ft.
250 Ft. 300 Ft.
500 Ft. 600 Ft.
400 Ft. 500 Ft.
800 Ft. 1000 Ft.
100 Ft. 200 Ft. 300 Ft. 400 Ft.
0-2
2-3
18
18
18
18
18
18
18
16
16
16
14
14
18
18
18
18
16
16
14
14
12
12
12
12
18
16
16
14
14
12
12
10
10
10
8
16
14
14
12
12
10
10
8
16
14
12
12
10
10
8
14
12
12
10
10
8
14
12
10
10
8
12
10
10
8
12
10
8
3-4
4-5
8
5-6
8
6
6-8
6
6
6
8-10
10-12
12-14
14-16
16-18
18-20
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
FUNCTIONAL DESCRIPTION
Porter-Cable routers are designed for continuos, rugged operation to
handle the most demanding production applications.
ASSEMBLY
SELECTING THE BIT
These routers accommodate bits with 1/2" diameter shanks that are installed
directly into the power unit collet. Collets are available that will allow the use
of bits having 1/4" or 3/8" diameter shanks.
Do not use router bits with a diameter in excess of
21/2" in this machine.
While preparing the router for use, while making
adjustments and when router is not in use, ALWAYS
disconnect it from the power source.
INSTALLING AND REMOVING THE BIT
1.
DISCONNECT TOOL FROM POWER SOURCE.
2. Remove motor unit from base unit as follows:
(a) Loosen clamp screw (A) Fig. 1.
(b) While holding base, turn motor unit COUNTERCLOCKWISE until
lower pin (B) in motor housing is disengaged from groove in base.
(c) Lift motor unit free from base unit.
3. Clean and insert shank of bit into collet until shank bottoms. Then back
it out approximately 1/16".
4. Lay motor unit on its side on bench with the collet pointing AWAY from
you.
5. Place one wrench on flats on chuck with the opposite end of the wrench
resting on the bench to your left, Fig. 2.
6. Place other wrench on collet and tighten COUNTERCLOCKWISE as
shown in Fig. 2. TIGHTEN FIRMLY.
6
B
A
Fig. 1
7. To remove the bit, reverse the foregoing procedure. If bit does not
remove easily, tap the collet nut with wrench to release.
AVOID POSSIBLE DAMAGE TO COLLET.
NEVER TIGHTEN COLLET WITHOUT BIT.
ASSEMBLING THE MOTOR IN THE ROUTER BASE
EQUIPPED WITH TWO HANDLES
1.
DISCONNECT MOTOR FROM POWER SOURCE.
2. Loosen the clamp screw (A) Fig. 1 to allow the power unit to be set in
the base unit.
3. Insert motor unit into base aligning lower pin (B) with groove in base.
4. Rotate motor unit CLOCKWISE into base until upper guide pins are
rigidly set in the groove of the base.
5. Tighten clamp screw firmly.
ASSEMBLING THE MOTOR IN THE ROUTER BASE
EQUIPPED WITH SWITCH IN-HANDLE
1.
DISCONNECT BOTH POWER CORDS (base and motor)
FROM POWER SOURCE.
2. Loosen clamp screw (A) Fig. 3 to allow the power unit to be set in the
base unit.
3. With the motor switch (C) positioned as shown in Fig. 3, insert the motor
unit into the base aligning lower pin (B) with groove in base.
4. Rotate the motor unit CLOCKWISE into the base two revolutions.
5. Connect the motor unit cord to the outlet in handle as shown in Fig. 4.
6. Tighten clamp screw firmly.
C
B
A
Fig. 2
Fig. 3
7
ADJUSTING DEPTH OF CUT
C
1.
D I S C O N N E C T
TOOL FROM POWER SOURCE.
2. Loosen clamp screw (A) Fig. 5.
3. While holding base (E), turn
motor
unit
(F)
Fig.
5
COUNTERCLOCKWISE until the tip
of the bit is above bottom surface of
base.
Fig. 4
4. Set router on flat wood surface.
5. Turn motor unit (F) Fig. 5
CLOCKWISE until bit touches the
wood surface.
F
6. Tighten clamp screw (A) Fig. 5.
7. Rotate depth adjusting ring (B)
Fig. 5 until the zero-line (C) is
opposite the index line (D) on the
housing.
B
8. Loosen clamp screw (A) Fig. 5.
D
C
9. Tip the router so bit is clear of
the wood surface. Turn motor unit
(F) Fig. 5, CLOCKWISE until the
index line (D) on the motor housing
reaches the desired depth indicated
on the ring.
A
E
10. Tighten clamp screw (A) Fig. 5
firmly.
Fig. 5
1
NOTE: Setting the index line to /4" on the ring means the cutting
edge of the bit is exposed 1/4" below the base.
OPERATION
CONNECTING TO POWER
SOURCE
Before connecting
A
tool to power source, CHECK TO
SEE THAT THE SWITCH IS IN
THE “OFF” POSITION. Also,
check the power circuit to see that
it is the same as that shown on
specification plate of the tool.
Fig. 6
8
STARTING AND STOPPING
THE MOTOR
B
Before starting the
tool, clear the work area of all
foreign objects. Also keep firm grip
on tool to resist starting torque.
A
C
The motor units for these routers
can be used with either the base
having two handles or the base
with the switch-in-handle.
Fig. 7
When using the base with two handles, as shown in Fig. 6, the motor is
started and stopped by depressing the rocker switch (A) Fig. 6, into the ON
or OFF position.
When using the base with the switch-in-handle as shown in Fig. 7, be sure
the motor unit power cord (A) is plugged into the handle as in Fig. 7, and the
switch (B) on the motor is set to the ON position. The starting and stopping
of the motor is then controlled by depressing and releasing the trigger
switch (C) in the handle of base.
On applications when it is desirable to keep the motor running without
continually holding in the trigger switch (C) Fig. 7, simply depress the trigger
(C) into the handle and press in the switch locking the button on the side of
the handle. While holding the button in, slowly release the trigger. To stop
the motor, squeeze trigger into handle and release to disengage locking
button.
To avoid personal injury and/or damage to finished work,
always allow the motor to come to a COMPLETE STOP
before putting the tool down.
USING THE TOOL
IMPORTANT: Before using the tool, consider the kind and total amount of
material to be removed. More than one cut may be necessary to avoid
overloading the motor. Before beginning the cut on the actual workpiece,
make a sample cut on a piece of scrap lumber. This will allow you to see the
finished cut and to check dimensions.
Always be sure the work is rigidly clamped or otherwise
secured before making a cut.
Generally speaking, when working on a bench, the workpiece should be held
on the bench by wood clamps. When routing edges, hold the router firmly
down and against the work with both guiding handles.
Since the cutter rotates clockwise (when viewing router from top), the router
should be moved from left to right as you stand facing the work. When
working on the inside of a templet, move the router in a clockwise direction.
When working on the outside of a templet, move the router in a counter-
clockwise direction.
9
B
B
C
D
D
A
Fig. 8
Fig. 9
Avoid “Climb-Cutting” (cutting in direction opposite that shown
in Fig. 8). “Climb-Cutting” increases the chance for loss of control resulting in
possible injury. When “Climb-Cutting” is required (backing around a corner),
exercise extreme caution to maintain control of router. Make smaller cuts and
remove minimal material with each pass.
The speed and depth of cut will depend largely on the workpiece. Keep the
cutting pressure constant but do not crowd the router so the motor speed
slows excessively. On exceptionally hard woods or problem materials, more
than one pass at various settings may be necessary to get the desired depth
of cut.
When making cuts on all four edges of the workpiece, make the first cut on
the end of the piece across the grain. If chipping of wood occurs at the end
of a cut, it will be removed when making the next cut parallel with the grain.
Periodically wipe columns clean with a dry cloth. Clean the rack and gear on
the fixed base with a soft bristle brush. Do not lubricate either the columns or
the rack and gear.
THE EDGE GUIDE
An Edge Guide is available as an accessory to aid in routing operations such
as: straight edge planing, parallel grooving, dado or slotting operations.
To assemble, insert guide rods (A) in holes in base, Fig. 9 and secure with
screws (B). The guide (C) is adjusted on the rods and secured in desired
position with thumb screws (D).
TEMPLET GUIDES
A wide variety of templet guides is available for use in pattern and templet
routing operations. A typical combination bit, templet guide, and locknut are
illustrated in Fig. 10.
DISCONNECT TOOL FROM POWER SOURCE.
To install, insert templet guide in center hole in router base and secure in
place with a locknut. Before connecting router to power source, install the
bit, adjust the depth of cut, and rotate the router chuck by hand to ensure
that bit or collet do not contact the templet guide.
LOCKNUT
ROUTER
BASE
TEMPLET GUIDE
ROUTER BIT
SUB-BASE
Fig. 10
10
MAINTENANCE
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic
parts should be cleaned with a soft damp cloth. NEVER use solvents to
clean plastic parts. They could possibly dissolve or otherwise damage the
material.
Wear safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord
plug are making good contact in the outlet. Also, check for blown fuses or
open circuit breakers in the line.
LUBRICATION
This tool has been lubricated with a sufficient amount of high grade lubricant
for the life of the unit under normal operating conditions. No further
lubrication is necessary.
BRUSH INSPECTION AND LUBRICATION
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE·DELTA
FACTORY SERVICE CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and
inspected. Have worn parts replaced and lubricate with fresh lubricant. Have
new brushes installed, and test the tool for performance.
Any loss of power before the above maintenance check may indicate the
need for immediate servicing of your tool. DO NOT CONTINUE TO
OPERATE TOOL UNDER THIS CONDITION. If proper operating voltage is
present, return your tool to the service station for immediate service.
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due
to wear from normal use. These operations, including brush inspection and
replacement, should ONLY be performed by either an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE·DELTA
FACTORY SERVICE CENTER. All repairs made by these agencies are fully
guaranteed against defective material and workmanship. We cannot
guarantee repairs made or attempted by anyone other than these agencies.
Should you have any questions about your tool, feel free to write us at any
time. In any communications, please give all information shown on the
nameplate of your tool (model number, type, serial number, etc.).
11
ACCESSORIES
A complete line of accessories is available from your Porter-Cable•
Delta Supplier, Porter-Cable•Delta Factory Service Centers, and Porter-
Cable Authorized Service Stations. Please visit our Web Site
www.porter-cable.com for a catalog or for the name of your nearest
supplier.
Since accessories other than those offered by Porter-
Cable •Delta have not been tested with this product,
use of such accessories could be hazardous. For
safest operation, only Porter-Cable•Delta
recommended accessories should be used with this
product.
EDGE GUIDE 42225
COLLETS
** 42999 1/4" Collet Assembly, includes:
876669
875893
823030
Collet, 1/4"
Nut
Snap-Ring
** 42975 3/8" Collet Assembly, includes:
876670
875893
823030
Collet, 3/8"
Nut
Snap-Ring
** 42950 1/2" Collet Assembly, includes:
876671
875893
823030
Collet, 1/2"
Nut
Snap-Ring
SUB-BASES 10695 Standard
42187 Clear (21/2" Hole)
1
WRENCH
42596 1/8"
TEMPLET GUIDES
No. 42000 Templet Guide Kit – Contains one each of Nos. 42054, 42036,
42027, 42033, 42045, 42024, and 42042 templet guides, and two No. 42237
lock nuts.
↓
C
↑
←
→
A
←
→
B
12
A
B
C
Distance
Past Base
Model No.
42021
42024
42027
42030
42033
42036
42039
42042
42045
42048
42054
45101
45102
42237
ID
OD
11/4"
3/4"
11/32"
21/32"
11/32"
25/32"
13/32"
9/32"
3/4"
5/8"
17/32"
13/8"
1/4"
13/64"
13/64"
7/16"
9/16"
5/32"
3/8"
5/16"
5/16"
9/16"
9/16"
9/16"
17/32"
5/32"
7/16"
17/32"
7/16"
1"
1/2"
3/8"
59/64"
51/64"
5/8"
135/64"
5/16"
119/64"
13/8"
Lock Nut – For all templet guides
13
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to repair or replacement required
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service
Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary
from state to state.
14
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
Cleveland 44125
8001 Sweet Valley Drive
Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
ARIZONA
MINNESOTA
Minneapolis 55429
5522 Lakeland Avenue North
Phone: (763) 561-9080
Fax: (763) 561-0653
ILLINOIS
Tempe 85282 (Phoenix)
2400 West Southern Avenue
Suite 105
Phone: (602) 437-1200
Fax: (602) 437-2200
Addison 60101 (Chicago)
400 South Rohlwing Rd.
Phone: (630) 424-8805
Fax: (630) 424-8895
OREGON
Portland 97230
4916 NE 122 nd Ave.
Phone: (503) 252-0107
Fax: (503) 252-2123
MISSOURI
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
CALIFORNIA
North Kansas City 64116
1141 Swift Avenue
Phone: (816) 221-2070
Fax: (816) 221-2897
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
MARYLAND
St. Louis 63119
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
7574 Watson Road
Phone: (314) 968-8950
Fax: (314) 968-2790
PENNSYLVANIA
Willow Grove 19090
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
NEW YORK
MASSACHUSETTS
Braintree 02185 (Boston)
719 Granite Street
Phone: (781) 848-9810
Fax: (781) 848-6759
COLORADO
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
Arvada 80003 (Denver)
8175 Sheridan Blvd., Unit S
Phone: (303) 487-1809
Fax: (303) 487-1868
TEXAS
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
FLORIDA
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Tampa 33609
4538 W. Kennedy Boulevard
Phone: (813) 877-9585
Fax: (813) 289-7948
Houston 77038
4321 Sam Houston Parkway, West
Suite 180
Phone: (281) 260-8887
Fax: (281) 260-9989
OHIO
MICHIGAN
Columbus 43214
4560 Indianola Avenue
Phone: (614) 263-0929
Fax: (614) 263-1238
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
WASHINGTON
Auburn 98001(Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
GEORGIA
Forest Park 30297 (Atlanta)
5442 Frontage Road,
Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-
•
•
•
•
•
•
•
•
Cable
•
Delta, s’adresser à tout distributeur Porter-Cable
•
Delta, centre de service agréé ou centre de service d’usine Porter-Cable
•
Delta. Si
Delta le
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable
•
plus proche.
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste, Suite 180
Québec, Québec
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Montréal), Québec
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 767-4132
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®,
Flying Chips™, FRAME SAW®, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-SET®,
Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, Posi-Matic®, Q-3®&(design), QUICKSAND®&(design), QUICKSET™,
QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®, Sanding Center®, SANDTRAP®&(design), SAW BOSS®,
Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®, The American Woodshop®&(design), The Lumber
Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-LINE™, TIGER®, TIGER CUB®, TIGER SAW®,
TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®, UNIFEEDER™, Unihead®, Uniplane™, Unirip®,
Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®, WOODWORKER’S CHOICE™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other
countries. Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y
también pueden estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets
d’invention et marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
Download from Www.Somanuals.com. All Manuals Search A
P
n
r
d
in
D
n
U
lo.S
a
.
d
A
.
.
PC-0603-150
|