Raytherm® - Type H
Job:
Engineer:
Contractor:
Prepared By:
Model:
Hydronic Heating Boilers
Models 182-400 - Indoor
Date:
Indoor
EFFICIENT
ꢀ 82% efficiency – highest of any atmospheric boiler
available today
THERMAL SHOCK PROOF
ꢀ Twenty-year warranty against thermal shock damage
up to 150°F differential
ꢀ Maximum operating temperature: 230°F
LIGHTWEIGHT
ꢀ A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY
ꢀ Cuts fuel costs substantially because the standby and
radiation losses normal to other boilers and
tank-type water heaters are eliminated
LOW WATER OPERATING TEMPERATURE
ꢀ Operates with water temperature as low as
105°F without condensing
Heat Exchanger
Gas Control Train
Temperature Controls
ƒ
ASME Inspected and Stamped
160 PSIG
National Board Approved
Headers
Cast Iron Glass-lined – Standard
Bronze – Option A-1
Finned Tubing
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Main Gas Shut-off Cock
Note: H1 and H5 do not require a
controller
Main Gas Pressure Regulator
Redundant Safety Shut-off Valve
Control Valve
ƒ
ƒ
B-6 Two-stage – 100-200ºF
Y-241 Electronic Sequencer,
1-4 Stages
Y-281 Electronic Sequencer,
1-8 Stages
Firing Mode
On/Off (H4)
ƒ
Two-stage Firing (H3)
Mechanical Modulation,
110-170°F (H5)
Mechanical Modulation,
150-210°F (H1)
Copper – Standard
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone O-Rings
ASME Pressure Relief Valve
45 PSIG – Standard
PSIG ASME – Optional
Temperature and Pressure Gauge,
Shipped Loose
Additional Safety Controls
ƒ
ƒ
ƒ
F-10 Low Water Cut-off Probe
I-1
High Limit Control, Auto
Reset, 240°F
ƒ
ƒ
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.13
S-1 Low Gas Pressure Switch,
Manual
S-2 High Gas Pressure Switch,
Manual
ƒ
ƒ
Construction
Water Connections
ƒ
ƒ
ƒ
ƒ
Front Controls
Left Hand – Standard
Right Hand – Option A-6
Flow Configuration – Two-pass
Pump – Optional
Stainless Steel Burners
Polytuf Powder Coat Finish
Vent Selection
Draft Diverter – Option D-10
Power Vent, Loose – Option D-2
Base (Optional)
ƒ
ƒ
Regulatory Agency Requirements
Mounted, 1/8 HP, 120 Volt, 1∅, 60 Hz
Controls
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1 Ph Power Supply
120/24V Transformer
100% Pilot Shut-off/Lockout
Electronic, Intermittent Ignition (IID) Pilot
High Limit Control, Manual Reset
On/Off Switch
Combustible Floor Shield –
Option J-1
Flow Switch
Economaster II Pump Time Delay
Catalog No.: 2000.205D
Effective: 1-1-08
Replaces: 4-1-05
|
Raritan Computer Calculator PMG 0I v203 E User Guide
RCA MP3 Player M4202 User Guide
Riccar Vacuum Cleaner GEM R User Guide
Roland Music Pedal VG 99 User Guide
Roland Switch MSQ 100 User Guide
Ryobi Blower RESV1300 User Guide
Samsung DVR SRN 472S 1TB User Guide
Samsung Laptop NP270E5EK01JM User Guide
Samsung Printer ML 1710 User Guide
Samsung Security Camera SCC C4253P User Guide