Hi Delta® - Type P
Job:
Engineer:
Contractor:
Prepared By:
Model:
Commercial Pool Heaters
Models 992B-1532B
Date:
Indoor/Outdoor:
MBTUH Input:
Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-assisted
Non-ferrous Bypass
Patented Burner Security Blanket
Heat Exchanger
Gas Train
Options
ꢀ
ꢀ
Bronze Headers
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Gas Pressure Regulators
C-6 Ignition Module, Manual Reset
D-21 TruSeal™ Direct Vent
Left Side - Standard
Right Side - Optional
F-10 Low Water Cut-off, Remote Probe
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Cupro Nickel Finned Tubing
ASME Steel Tube Sheet
Silicone High Temp O-Rings
125 PSIG ASME Pressure Relief
Valve
Temperature and Pressure Gauge
Water Connections
Left – Standard
Right – Option A-6
Bronze Pump, 1/2 HP, 120V, 60Hz
Non-ferrous Pool Bypass
Safety Shut-off Valves
Firing Control Valves
On/Off Firing
Low Gas Pressure Switch, Manual
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.56/
CSA 4.7
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
I-5
S-2
High Limit Control, Manual Reset
High Gas Pressure Switch, Manual
(Dual switches on Model 1532B)
SureRack Kit, Zone III and IV
SureRack Add-on, Zone IV
ꢀ
X-1
X-2
ꢀ
ꢀ
Y-241 Temperature Controller,
1-4 Stages
Burner
Ultra-low NOx:
Less than 30 PPM
ꢀ
Regulatory Agency Requirements
G-1
ꢀ
ꢀ
CSD-1
Construction
ꢀ
ꢀ
Indoor/Outdoor Construction
Enclosed Front Controls
Controls
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
120V, 60Hz, 1∅ Power Supply
120/24V 60Hz Transformer
100% Shut-off/Lockout
Hot Surface Ignition System
Remote Flame Sensor
High Limit Control, Auto Reset
On/Off Power Switch
Manual Shut-off, Front-mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Poolstat
Venting
ꢀ
Vent Location
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor – Option D-11
Indoor, Horizontal –
Option D-15
ꢀ
Indoor, Vertical (by others)
Combustion Air
ꢀ
In-Line Filter Kit (TruSeal
only) – Option D-17
Air Intake Elbow –
Option D-16
L
W
Catalog No.: 6000.332B
Effective: 8-15-08
Replaces: 3-1-07
|
QSC Audio Speaker System SC 323 User Guide
Radio Shack Cordless Telephone 43 1088 User Guide
Radio Shack MP3 Player 42 541 User Guide
Radio Shack Pill Reminder Device 63 1516 User Guide
ResMed Sleep Apnea Machine 628035 User Guide
Roadmaster Car Stereo System VR500CS BT User Guide
Roberts Radio Radio RD 6 User Guide
Sagem Cell Phone myX3 2 User Guide
Sanyo Air Conditioner 85464359981002 User Guide
SECO LARM USA Security Camera EV 1323C12DWQ User Guide