Coleman Air Conditioner 100 RANG User Manual

6. For indoor use only. Area must be well ventilated.  
Provide minimum openings, of 2 sq. ft. near the floor  
and 2 sq. ft. near the ceiling.  
7. If at any time gas odor is detected, IMMEDIATELY  
DISCONTINUE operation until the source of gas has  
been located and corrected.  
8. Install the heater such that it is not directly exposed to  
water spray, rain and/or dripping water or wind.  
9. Maintain minimum clearance from normal combustible  
materials of 6 feet in all directions. Locate 10 ft. from  
canvas tarpaulins or similar coverings and secure them  
to prevent flapping or movement due to wind action.  
10. Operate only on a stable, level surface.  
11. Since permanent skin tissue damage can occur, avoid  
contact with the unit while is is operating or shortly after  
it has been shut off.  
SCHEUPRODUCTS COMPANY,INCORPORATED  
Mail: P.O. Box 250, Upland, CA 9l785  
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730  
Telephone:909-981-5343  
ASSEMBLYANDOPERATING INSTRUCTIONS  
MODELS 100-RANG/SPC-100RANG  
CONSTRUCTIONHEATER  
YOUR SAFETY IS IMPORTANT TO YOU AND TO  
OTHERS, SO PLEASE READ THESE INSTRUCTIONS  
BEFORE YOUOPERATE THIS HEATER.  
GENERALHAZARDWARNING:  
12. Do not use on combustible floors.  
FAILURE TO COMPLY WITH THE PRECAUTIONS  
13. Do not move, handle or service while hot or burning.  
14. Use only in accordance with local codes.  
15. Installation of this natural gas heater must conform with  
local codes or, in the absence of local codes, with the  
National Fuel gas Code ANSI Z223.1NFPA 54  
PREPARING FOR OPERATION  
1. Check the heater for possible shipping damage. If any  
is found, immediately notify your dealer.  
2. Follow all of the "Safety Precautions."  
3. Install plumbing to a low pressure (1/2 psig maximum)  
source of natural gas, using a minimum 3/4" i.d. hose  
or flexible connector not over 10 feet in length.  
4. Connect the hose to the heater at the 1/2" SAE flare  
fitting at the inlet.  
ANDINSTRUCTIONS PROVIDED WITH THIS HEATER,  
CANRESULT IN DEATH, SERIOUS BODILY INJ URY  
ANDPROPERTY LOSS OR DAMAGE FROM HAZARDS  
OF FIRE, EXPLOSION, BURN, ASPHYXIATION, AND  
CARBONMONOXIDE POISONING.  
ONLY PERSONS WHO CAN UNDERSTAND AND  
FOLLOW  
THE INSTRUCTIONS SHOULDUSE OR SERVICE THIS  
HEATER.  
IFYOUNEEDASSISTANCEORHEATERINFORMATION  
SUCHAS ANINSTRUCTIONS MANUAL,LABELS,ETC.  
CONTACTTHE MANUFACTURER.  
5. Securely tighten all gas connections.  
6. Open the gas cock and check all gas connections with a  
START  
WARNING: FIRE,BURN,INHALATION,  
1. Fully open the gas cock at the natural gas source.  
2. Place control knob of the safety pilot valve in pilot  
position and depress the knob admitting gas to pilot.  
Push and release the piezo button until the pilot lights,  
multiple tries may be necessary. Alternately place a  
AND EXP LOS ION HAZARD.  
KEEP S OLID  
COMBUSTIBLES, SUCH AS BUILDING MATERIALS,  
PAPER OR CARDBOARD, A SAFE DISTANCE AWAY  
FROM THE HEATER AS RECOMMENDED BY THE  
INSTRUCTIONS. NEVERUSETHEHEATERINSPACES  
WHICHDOORMAYCONTAINVOLATILEORAIRBORNE  
COMBUSTIBLES,ORPRODUCTS SUCHAS GASOLINE,  
SOLVENTS, PAINT THINNER, DUST PARTICLES OR  
UNKNOWNCHEMICALS.  
lighted match near  
the pilot (pilot is above cutout in  
the middle pan). If hose is filled with air, allow a few  
minutes for gas to reach the pilot.  
3. When the pilot lights, continue to hold the button on the  
safety pilot valve depressed for 30 seconds, then  
release.  
4. If the pilot goes out, wait 5 minutes and repeat the start  
procedure.  
OPERATINGINFORMATION  
5. When the pilot remains lit, turn the knob left 1/4 turn to  
the "ON" position and the main burner will light.  
CAUTION: INADEQUATE FUEL SUPPLY or lowering burn  
rate can cause sooting.  
Intended use is primarily the temporary heating of buildings  
under construction, alteration or repair.  
STOP  
WARNING  
1. Securely close the gas cock at the gas source.  
2. Depress the control knob of the pilot valve and turn  
clockwise to "OFF" position.  
RESTARTAFTERSAFETYSHUTDOWN  
1. Securely close gas cock at the gas source.  
2. Wait 5 minutes.  
NOTFOR HOME OR RECREATIONALVEHICLE USE.  
SAFETYPRECAUTIONS  
1. Check the heater thoroughly for damage. DO NOT  
operate a damaged heater.  
2. DO NOT modify the heater or operate a heater  
which has been modified from its original condition.  
3. Provide at least 5" W.C. but not over 1/2 psig to the  
heater inlet.  
3. Restart following "Start" procedure.  
4. Use an appropriate hose or flexible connector not over  
10 ft. in length.  
5. Operate the heater only with the 4" W.C. regulator  
provided by the factory.  
ANSI Z83.7b-1993/CGA 2.14-1972  
Construction Heater  
 

Conair Pedicure Spa FB3 User Manual
Contec Universal Remote RT U50 25S User Manual
Cranium Games Mix Match Memory Game User Manual
Cuisinart Blender 09CE13231 User Manual
Curtis Turntable RCD817 User Manual
Electro Voice Microphone N D457 User Manual
Fellowes Paper Shredder 4800CC User Manual
Garland Range PS 12G 2 20 User Manual
Garmin Car Stereo System 695 User Manual
GE Monogram Oven ZET737BW User Manual