Installation,
Operation &
Maintenance
Instructions
Fine Cooking Equipment For Over 70 Years
CEG SERIES THERMOSTATIC GRIDDLES
For Your Safety
Warning!
Do NOT store or use gasoline or
other flammable vapors and
liquids in the vicinity of this, or
any other equipment.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or
death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing
this equipment.
To Purchaser
After installation of your griddle, immediately contact your local gas supplier to obtain
information in the event the user of your equipment smells gas. This information must be
posted in a prominent location.
To User
RETAIN THIS MANUAL FOR FUTURE USE
Upon receipt of this griddle, inspect it thoroughly for any damage which may have occurred
during shipment. If damage is observed, contact the delivery agency immediately.
1. Preparation For Installation: Safe and satisfactory operation of the griddle depends, to a great
extent, upon it’s proper installation. It should be installed in accordance with the National Fuel
Gas Code Z223.1, these instructions, and applicable State and Local Codes.
Installation must be made by a licensed plumber.
A gas pressure regulator is supplied with your griddle. The regulator must be installed before
connecting griddle to gas supply line. Please note: air vent can plug with grease, thereby shutting
gas supply off. Install regulator in a drip-free area.
The griddle and it’s individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45
kPa).
The griddle must be isolated from the gas supply piping system by closing it’s individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.45 kPa).
2. Clearances And Ventilation: This griddle is designed for installation in non-combustible locations
only with 4” clearance from sides and 6” clearance from back.
The Connerton Company
1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145
Telephone: (714) 547-9218 Fax: (714) 547-1969
1
8
14
7
9
6
2
11
10
12
13
5
3
4
CEG THERMOSTATICALLY-CONTROLLED GRIDDLES
1. 05-476-xx
2. 05-400-xx
3. 05-426-xx
4. 05-450-00
5. 05-301-xx
6. 05-200-01
05-200-02
Griddle Plate
Body
Front Panel
Grease Pan
Gas Manifold
Orifice Hood - Natural
Orifice Hood - Propane
Air Shutter
9. 05-350-00
10. 00-225-00
11. 05-251-01
05-251-02
12. 00-525-00
13. 05-550-00
14. 00-275-01
00-275-02
Pilot w/tubing
Pilot Valve
Thermostatic Control (right)
Thermostatic Control (left)
Thermostatic Knob Bezel
Thermostatic Control Knob
Regulator - Natural
7. 05-675-00
8. 05-150-00
Regulator - Propane
Burner
*** For part numbers ending in xx, specify model size (ie; 05-400-48 for a CEG-48)
TROUBLESHOOTING GUIDE
Condition
Probable Cause
Solution
Small/no burner flame
Regulator failure
Unplug regulator vent hole or
replace regulator.
Thermostatic calibration
By-pass setting
Re-calibrate thermostat.
Adjust by-pass setting.
Unplug hole or replace orifice.
Unplug burner port(s).
Plugged orifice hood
Plugged burner port
Small/no pilot flame
Yellow burner flame
Pilot valve setting
Plugged pilot tip
Adjust flame height.
Unplug pilot ports.
Improper air shutter setting
Increase air shutter setting until
flame is blue.
Enlarged orifice hood
Replace w/correct orifice.
Flame lifts off burner
Improper air shutter setting
Decrease air shutter setting
until flame sits on burner.
Plugged orifice hood
Improper level setting
Unplug orifice hole or replace orifice.
Adjust level w/feet or shims.
Too hot/cold
Improper control setting
Adjust control setting or replace
control.
Improper level setting
Adjust level w/feet or shims.
Thermostatic calibration
Re-calibrate thermostat and by-pass.
LIMITED WARRANTY
The Connerton Company warrants to the original user for a period of one year from date of
installation, not to exceed 18 months from date of shipment by Connerton, that the equipment
manufactured is free from defects in material or workmanship.
Our obligation under this warranty shall be limited to furnishing without charge any part of said
product which, upon examination by The Connerton Company shall prove to be defective. Parts wear
is not considered a defect. The Connerton Company will not be responsible for labor or
transportation charges incidental to the replacement of same.
The Connerton Company assumes no responsibility for failure of the equipment to operate properly
due to improper installation or operation. This warranty applies to all equipment that has been
unaltered, properly installed and maintained in accordance with national and local codes and in
accordance with the installation and operating instructions included with this equipment.
This warranty does not extend to normal maintenance items, including but not limited to,
thermostatic calibrations, air and gas adjustments and adjustments to pilot flames. Proper
installation, adjustments, calibration and initial checkout is the responsibility of the dealer, the
owner-user or installer and not that of The Connerton Company.
Please fill out and refer to the following when contacting the factory:
Model # CEG
-T
Serial#
Gas Type:
Purchase Date:
|