Dymo Scale PS2R1 P User Manual

ELECTRONIC WEIGHING INSTRUMENTS  
OPERATOR’S MANUAL  
MODEL NO. PS2R1-P  
32 oz./1000 g capacity  
Envelopes/Small Packages  
Please take a few minutes to read this Operator’s manual so that you can become  
acquainted with the proper usage and special features of your PELOUZE® DIGITAL SCALE.  
 
2. Press COUNT. Display will show “Ad 10”. Add 10 like pieces, weighing a minimum of 1 oz**. Display will  
show “Pr. C”.  
3. Press COUNT. Display will show “10”. Add desired like pieces to be counted.  
4. Display will show total pieces counted. Remove pieces counted.  
5. Press ZERO. Display will show “0.0” indicating ounce mode.  
Note: If pieces to be counted require a container, place empty container on platform before following steps 1  
through 5.  
** If pieces to be counted do not total at least 1 oz, you must add additional pieces in multiples of 10 until 1 oz or more is attained (e.g. 10, 20, 30  
pieces). In order to arrive at the correct quantity, you must multiply the final piece count shown in step 4 by the number of multiples of 10 pieces  
used in step 2.  
AUTOMATIC OFF: When powered by a battery, the scale will automatically turn off after approximately 30  
seconds of inactivity (no weight change). This prolongs Battery life.  
To deactivate Automatic Turn Off: While scale is off, PRESS and HOLD ZERO. While still holding ZERO  
press ON until “SHOF” appears briefly in display. This feature is automatically deactivated when the scale is  
powered by a 120V adapter.  
To reactivate Automatic Turn Off: PRESS OFF to turn off scale. Press ON again to turn the scale back on  
and Automatic Off will be activated.  
OVERLOAD WARNING: “  
” appearing in the upper half of display indicates you have exceeded Scale  
capacity.  
LOW BATTERY WARNING: Blinking “  
” appearing on display indicates low battery.  
RATE CHANGE INSTRUCTIONS  
You have the option of changing Rates by purchasing and replacing the rate chip (visit our website  
www.pelouze.com or contact us at 1-888-807-2253) or by programming the new rates into the scale  
yourself. To program the new rates, follow this procedure:  
A
B
1. Initiate Program Mode. With the scale turned off, Press  
and Hold the A key (see diagram at right) and Press and  
Hold ON at the same time. The display will show  
“ then “2162” or the current version code,  
“USPS” and finally the 1 oz 1st Class postage rate (the last  
digit blinking).  
IMPORTANT: If “Err6” or “0” appear, STOP! The wrong two  
buttons have been pressed. Turn Scale Off. Begin again.  
2. Enter New Rate from Right to Left. As each digit blinks,  
Press and Hold the B key to change it. Press D to move  
left to the next digit. When the new rate is completely  
entered, Press the C key to store in memory.  
C
D
3. Complete Rate Changes. Repeat step 2 to enter all 1st Class rate changes up to 16 oz (use Priority Mail  
postage rates for 13 oz to 16 oz rates) and then all Express Mail rate changes up to 32 oz. When you  
complete the 32 oz Express Mail postage rate, “ACCP” will appear on the display, verifying acceptance of  
the new rates.  
4. Press OFF to turn scale off. Scale is now ready to resume normal use.  
CARE & CLEANING  
Your PS2R1-P is a precision instrument, engineered to give years of valuable service. Care should be given  
to maintain its accuracy and appearance. PROTECT YOUR SCALE FROM:  
• Being Dropped  
• Shock Loading  
• Excessive weight  
• Extreme Temperatures  
• Liquid Spills  
• Other Abuses  
This scale is easily cleaned by wiping with a damp, soft cloth and mild nonabrasive detergent.  
SPECIFICATIONS  
DIMENSIONS: 5" x 6 3/4” x 2 1/16"  
PLATFORM SIZE: 4 3/4” x 4 1/8"  
CAPACITY: 32 oz./1000g x 0.1 oz/1 g. MODEL NO.: PS2R1-P  
POWER SOURCE: 9V Battery or Pelouze ADPT2 Adapter with 120V AC 60Hz 3W input/ 9V DC 100mA  
Output  
- 3 -  
 
NOT LEGAL FOR TRADE  
1 YEAR LIMITED WARRANTY  
What does this Warranty Cover?  
Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a  
period of 1 year. If product fails to function properly, return the product, prepaid and properly packed to Pelstar. If  
manufacturer determines that a defect of material or in workmanship exists, customers' sole remedy will be repair  
or replacement of scale at no charge. Replacement will be made with a new or remanufactured product or  
component. If the product is no longer available, replacement may be made with a similar product of equal or greater  
value. All parts including repaired and replaced parts are covered only for the original warranty period.  
Who is Covered?  
The original purchaser of the product must have proof of purchase to receive warranty service. Pelstar dealers  
or retail stores selling Pelstar products do not have the right to alter, or modify or any way change the terms and  
conditions of this warranty.  
What is Excluded?  
Your warranty does not cover obsolete dials or chips due to postal rate changes, normal wear of parts or damage  
resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use  
contrary to the operating instruction, abuse including tampering, damage in transit, or unauthorized repair or  
alternations. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes. This  
warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province  
to province or jurisdiction to jurisdiction.  
To get Warranty Service  
Make sure you keep your sales receipt or document showing proof of purchase.  
Call 1 (800) 638-3722 to receive a return authorization. Attach proof of purchase to your defective product along  
with your name, address,daytime telephone number and description of the problem. Carefully package the product  
and send with shipping and insurance prepaid to:  
Pelstar LLC  
Attention: R/A# _________  
Repair Department  
7400 W. 100th Place  
Bridgeview, IL 60455  
If your scale is not covered by warranty, or has been damaged, an estimate of repair costs or replacement costs  
will be provided to you for approval prior to servicing or replacing.  
Technical Service/Returns: 800-638-3722  
Customer Service: 800-654-8330  
Postal Rate Increase: 888-807-2253  
Pelstar LLC  
Bridgeview, Illinois 60455  
All rights reserved  
Pelouze® is a registered trademark of Pelstar LLC  
Made in China to our exact specifications  
04.03  
55440  
 

Clover Electronics Water Dispenser B7A User Manual
Craftsman Chipper 247776360 User Manual
Dynex Digital Photo Frame DX DPF7 User Manual
Eagle Electronics Fish Finder Supra ID User Manual
Earthquake Sound Speaker SWS 10X 4 OHM User Manual
Extron electronic Stereo Receiver VTR001 User Manual
First Alert Home Security System FA120C User Manual
First Alert Home Security System FA162C User Manual
GE Toaster 169075 User Manual
Gigabyte Network Router GN BR03GM User Manual