IV. Specifications
4) Wall Mount, aim to left:
ED120
ED200
Remove the iron case from the supporting
bracket by using screw driver to loosen the
two screws, which connect the iron case to
the supporting bracket. Turn the iron case
in 90-degree and mount into the supporting bracket again
by changing the screw holes in order to keep the screw
indicator on the top side.
ED120 Series
ED200 Series
Pickup Device:
Picture Element:
1/3 inch B/W interline 1/3 inch Color
transfer CCD
interline transfer CCD
510 x 492 (EIA)
500 x 580 (CCIR)
510 x 492 (NTSC)
500 x 580 (PAL)
Horizontal resolution: 420 TV lines (EIA)
400 TV lines (CCIR)
380 TV lines (NTSC)
340 TV lines (PAL)
Sensitivity:
0.04 lux/F=2.0
Over 48 dB
Up to 1/100,000
> 0.45
2.5 lux/F=2.0
Over 48dB
Up to 1/100,000
0.45
qConnect the video output of the camera (yellow line) to a B/W
monitor (ED120) or a color monitor (ED200), or other video
device through a 75 ohm type coaxial cable with BNC female
connector at cable extension.
S/N ratio:
INSTRUCTION
MANUAL
Electronic shutter:
Gamma Correction:
Video output:
Audio Output:
Power source:
rConnect the DC+12V regulated power source of the camera
(red line) to the DC12V Power-in jack with 2mm, center+,
outer- plug.
1.0Vp-p,75 ohm
Yes
1.0Vp-p,75 ohm
---
12VDC+/-10%,
150mA Max.
12VDC+/-10%,
250mA Max.
sConnect the ground of the camera (black line) to the ground.
Sync. Mode:
Lens Mount:
Dimension:
Internal Sync.
Internal Sync.
tConnect the audio output of the camera (white line) for EM120
to the audio connector of the monitor.
M12 x P0.5
M12 x P0.5
106mm Dia x 85mm H.
106mm Dia x 85mm H.
-10o C to +50o C
uPut the plastic cover back on the Dome Camera.
Operating Temperature: -10o C to +50o C
|