Driver Manual
(Supplement to the FieldServer Instruction Manual)ꢀ
FS-8700-39 EST3 ECP
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after September 2008
Driver Version:
Document Revision:
1.08
5
FS-8700-39 EST3 Driver Manual
Page 3 of 21
ꢀ
1.
EST3 Description
TheꢀEST3ꢀExternalꢀCommunicationsꢀProtocolꢀ(ECP)ꢀdriverꢀallowsꢀtheꢀFieldServerꢀtoꢀtransferꢀdataꢀtoꢀ
andꢀ fromꢀ ESTꢀ devicesꢀ overꢀ RSꢁ232ꢀ orꢀ RSꢁ485ꢀ (withꢀ converter)ꢀ serialꢀ portsꢀ usingꢀ theꢀ EST3ꢀ ECPꢀ
protocol.ꢀꢀInꢀtheꢀESTꢀapplicationꢀtheꢀFieldServerꢀalwaysꢀemulatesꢀaꢀClient.ꢀ
ꢀ
TheꢀFieldServerꢀmakesꢀuseꢀofꢀtheꢀfollowingꢀECPꢀServices:ꢀ
ꢀ
ReadꢀOperations:ꢀ
•ꢀ ReportꢀServiceꢀ
•ꢀ DeltaꢀServiceꢀ
WriteꢀOperations:ꢀ
•ꢀ CommandꢀServiceꢀ
ꢀ
AllꢀreadꢀpointsꢀareꢀcontinuallyꢀupdatedꢀusingꢀtheꢀReportꢀService;ꢀresponseꢀtimesꢀareꢀenhancedꢀusingꢀ
DeltaꢀServiceꢀbroadcastsꢀbyꢀtheꢀEST3ꢀpanel.ꢀ
ꢀ
Theꢀ informationꢀ thatꢀ followsꢀ describesꢀ howꢀ toꢀ expandꢀ uponꢀ theꢀ factoryꢀ defaultsꢀ providedꢀ inꢀ theꢀ
configurationꢀfilesꢀincludedꢀwithꢀtheꢀFieldServer.ꢀ
ꢀ
ꢀ
ꢀ
2.
Driver Scope of Supply
2.1. Supplied By FieldServer Technologies for this Driver
FIELDSERVER
DESCRIPTION
TECHNOLOGIES PART #
FSꢁ8915ꢁ10ꢀ
FSꢁ8917ꢁ03ꢀ
FSꢁ8917ꢁ10ꢀ
FSꢁ8700ꢁ39ꢀ
ꢀ
7’ꢀPatchꢀCableꢀ
RJ45ꢀtoꢀDB9MꢀConnectorꢀadapterꢀ
DB9FꢀtoꢀterminalꢀAdapterꢀ
EST3ꢀECPꢀDriverꢀManualꢀ
2.2.
Provided By the Supplier of 3rd Party Equipment
2.2.1.
ꢀ
Hardware
PART #
DESCRIPTION
EST3ꢀGatewayꢀ
VERSION
ꢀ
ꢀ
2.2.2.
Required 3rd Party Configuration
TheꢀEST3ꢀpanelꢀhasꢀtoꢀbeꢀsetꢀintoꢀtheꢀ“GatewayꢀMode”ꢀusingꢀtheꢀEST3ꢀConfigurationꢀtoolꢀ(3ꢁ
SDU)ꢀ
ꢀ
PossibleꢀProtocolsꢀ
ꢀ
ECPꢀTypeꢀIIꢀ
Supportedꢀ
ECPꢀTypeꢀIIꢀwithꢀTextꢀ
ECPꢀTypeꢀIIIꢀ
NotꢀSupportedꢀ
Supportedꢀ
NotꢀSupportedꢀ
ECPꢀTypeꢀIIIꢀwithꢀTextꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 4 of 21
ꢀ
3.
Hardware Connections
EST3ꢀECP
TB2
FS-8915-10
Modelꢀ8051
Function
FROMꢀDB9F/M
EST3ꢀECP
TB2
RX
TX
GND
Pinꢀ2
Pinꢀ3
Pinꢀ5
TXꢀ2
RXꢀ2
COMꢀ2ꢀ
8917-03
8917ꢁ03
FS-8915-10
ConnectꢀtoꢀoneꢀofꢀtheꢀRSꢁ232ꢀ
PortsꢀonꢀtheꢀFieldServer
8
1
FieldServer
P1
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 5 of 21
ꢀ
4.
Configuring the FieldServer as a EST3 Client
Forꢀ aꢀ detailedꢀ discussionꢀ onꢀ FieldServerꢀ configuration,ꢀ pleaseꢀ referꢀ toꢀ theꢀ FieldServerꢀ Configurationꢀ
Manual.ꢀꢀTheꢀinformationꢀthatꢀfollowsꢀdescribesꢀhowꢀtoꢀexpandꢀuponꢀtheꢀfactoryꢀdefaultsꢀprovidedꢀinꢀtheꢀ
configurationꢀfilesꢀincludedꢀwithꢀtheꢀFieldServerꢀ(Seeꢀ“.csv”ꢀsampleꢀfilesꢀprovidedꢀwithꢀtheꢀFieldServer).ꢀ
Thisꢀ sectionꢀ documentsꢀ andꢀ describesꢀ theꢀ parametersꢀ necessaryꢀ forꢀ configuringꢀ theꢀ FieldServerꢀ toꢀ
communicateꢀwithꢀanꢀEST3ꢀServer.ꢀ
ꢀ
4.1.
Data Arrays
TheꢀconfigurationꢀfileꢀtellsꢀtheꢀFieldServerꢀaboutꢀitsꢀinterfaces,ꢀandꢀtheꢀroutingꢀofꢀdataꢀrequired.ꢀInꢀ
orderꢀtoꢀenableꢀtheꢀFieldServerꢀforꢀEST3ꢀcommunications,ꢀtheꢀdriverꢀindependentꢀFieldServerꢀbuffersꢀ
needꢀ toꢀ beꢀ declaredꢀ inꢀ theꢀ “Dataꢀ Arrays”ꢀ section,ꢀ theꢀ destinationꢀ deviceꢀ addressesꢀ needꢀ toꢀ beꢀ
declaredꢀ inꢀ theꢀ “Clientꢀ Sideꢀ Nodes”ꢀ section,ꢀ andꢀ theꢀ dataꢀ requiredꢀ fromꢀ theꢀ serversꢀ needsꢀ toꢀ beꢀ
mappedꢀinꢀtheꢀ“ClientꢀSideꢀMapꢀDescriptors”ꢀsection.ꢀꢀDetailsꢀonꢀhowꢀtoꢀdoꢀthisꢀcanꢀbeꢀfoundꢀbelow.ꢀ
Noteꢀthatꢀinꢀtheꢀtables,ꢀ*ꢀindicatesꢀanꢀoptionalꢀparameter,ꢀwithꢀtheꢀboldꢀlegalꢀvalueꢀbeingꢀtheꢀdefaultꢀ
ꢀ
ꢀ
Section Title
Data_Arraysꢀ
Column Title
Data_Array_Nameꢀ
Data_Formatꢀ
Data_Array_Lengthꢀ
ꢀꢀꢀ
Function
ProvideꢀnameꢀforꢀDataꢀArrayꢀ
Providesꢀdataꢀformatꢀ
Legal Values
Upꢀtoꢀ15ꢀalphanumericꢀcharactersꢀ
UINT16ꢀ
NumberꢀofꢀDataꢀObjectsꢀ
1ꢀꢁꢀ10000ꢀ
Example
//ꢀꢀꢀꢀDataꢀArraysꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Data_Arraysꢀ
Data_Array_Nameꢀ
DA_AI_01ꢀ
DA_AO_01ꢀ
DA_DI_01ꢀ
DA_DO_01ꢀ
ꢀ
ꢀ
,Data_Formatꢀ
,Floatꢀ
,Data_Array_Lengthꢀ
,200ꢀ
,200ꢀ
,200ꢀ
,200ꢀ
,Floatꢀ
,Bitꢀ
,Bitꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 6 of 21
ꢀ
4.2.
Client Side Connection Descriptors
Section Title
Connectionsꢀ
Column Title
Function
Specifyꢀwhichꢀportꢀtheꢀdeviceꢀisꢀconnectedꢀtoꢀtheꢀ
FieldServerꢀ
Legal Values
P1ꢁP8,ꢀR1ꢁR21ꢀ
9600,ꢀ192002ꢀ
Portꢀ
Baudꢀꢀ
Specifyꢀbaudꢀrateꢀ
Parity*ꢀ
Data_Bits*ꢀꢀ
Protocolꢀ
Specifyꢀparityꢀ
Specifyꢀdataꢀbitsꢀ
Specifyꢀprotocolꢀtoꢀbeꢀusedꢀbyꢀthisꢀportꢀ
None
8
EST3ꢀ
Example
//ꢀꢀꢀꢀClientꢀSideꢀConnectionsꢀ
ꢀ
Connectionsꢀ
Portꢀ
P8ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
,Baudꢀ
,19200ꢀ
,Parityꢀ
,Noneꢀ
,Data_Bitsꢀ
,8ꢀ
,Protocolꢀ
,EST3ꢀ
ꢀ
4.3.
Client Side Node Descriptors
Section Title
Nodesꢀ
Column Title
Function
ProvideꢀnameꢀforꢀNodeꢀ
Legal Values
Upꢀtoꢀ32ꢀalphanumericꢀ
charactersꢀ
Node_Nameꢀ
Node_IDꢀ
Protocolꢀ
MACꢀIDꢀofꢀFieldServerꢀ
Specifyꢀprotocolꢀusedꢀ
1ꢀ–ꢀ24ꢀ(normallyꢀ1)ꢀ
EST3ꢀ
Specifyꢀwhichꢀportꢀtheꢀdeviceꢀisꢀconnectedꢀtoꢀ
theꢀFieldServerꢀ
Portꢀ
P1ꢁP8,ꢀR1ꢁR21ꢀ
Specifyꢀtimeꢀallowedꢀbetweenꢀpollꢀandꢀ
responseꢀ
Timeoutꢀ
≥10ꢀsecondsꢀ
ꢀ
ꢀꢀ
Example
//ꢀꢀꢀꢀClientꢀSideꢀNodesꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Nodesꢀ
Node_Nameꢀ
EST_1ꢀ
ꢀ
,Node_IDꢀ
,1ꢀ
,Protocolꢀ
,EST3ꢀ
,Portꢀ
,P8ꢀ
,Timeoutꢀ
,10sꢀ
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀ
1ꢀNotꢀallꢀportsꢀshownꢀareꢀnecessarilyꢀsupportedꢀbyꢀtheꢀhardware.ꢀConsultꢀtheꢀappropriateꢀInstructionꢀ
manualꢀforꢀdetailsꢀofꢀtheꢀportsꢀavailableꢀonꢀspecificꢀhardware.ꢀ
2ꢀEdwardsꢀRecommendsꢀ19200ꢁbaudꢀminimumꢀinꢀorderꢀtoꢀpreventꢀbufferꢀoverrunsꢀinꢀtheꢀEST3ꢀpanelꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 7 of 21
ꢀ
4.4.
4.4.1.
Client Side Map Descriptors
FieldServer Related Map Descriptor Parameters
Column Title
Function
Legal Values
Upꢀtoꢀ32ꢀalphanumericꢀ
charactersꢀ
Map_Descriptor_Nameꢀ NameꢀofꢀthisꢀMapꢀDescriptorꢀ
NameꢀofꢀDataꢀArrayꢀwhereꢀdataꢀ
Data_Array_Nameꢀ
OneꢀofꢀtheꢀDataꢀArrayꢀnamesꢀ
isꢀtoꢀbeꢀstoredꢀinꢀtheꢀFieldServerꢀ fromꢀ“DataꢀArray”ꢀsectionꢀaboveꢀ
0ꢀtoꢀmaximumꢀspecifiedꢀinꢀ“Dataꢀ
Data_Array_Offsetꢀ
Functionꢀ
StartingꢀlocationꢀinꢀDataꢀArrayꢀ
Array”ꢀsectionꢀaboveꢀ
FunctionꢀofꢀClientꢀMapꢀDescriptorꢀ RDBC,ꢀWRBC3,ꢀWRBXꢀ
4.4.2.
Driver Related Map Descriptor Parameters
Column Title
Function
Legal Values
Oneꢀofꢀtheꢀnodeꢀnamesꢀ
Node_Nameꢀ
NameꢀofꢀNodeꢀtoꢀfetchꢀdataꢀfromꢀ specifiedꢀinꢀ“ClientꢀNodeꢀ
Descriptor”ꢀaboveꢀ
EST_Panelꢀ
EST_Cardꢀ
Addressꢀ
Panelꢀ
Cardꢀ
0ꢀꢁꢀ63ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ1023ꢀ
Startingꢀaddressꢀofꢀreadꢀblockꢀ
ForꢀReads:ꢀ1ꢀtoꢀ34ꢀꢀꢀForꢀWrites:ꢀ
1ꢀ
Lengthꢀ
LengthꢀofꢀMapꢀDescriptorꢀ
Relay,ꢀLed,ꢀServGroup,ꢀ
GuardPtrl,ꢀChkInGrp,ꢀ
AltMessage,ꢀReset,ꢀPanelSil,ꢀ
AlarmSil,ꢀDrill,ꢀGAInhibit,ꢀ
Reboot,ꢀEvacuate,ꢀAltSensitiv,ꢀ
Partition,ꢀCmdList,ꢀInput,ꢀZone,ꢀ
Card,ꢀAndGroup,ꢀMatrix,ꢀ
TimeCtrl,ꢀInstructionText,ꢀ
AmpPower,ꢀAudMsg,ꢀCmdList,ꢀ
MCmsg,ꢀSetDate,ꢀSetTimeꢀ
0ꢀꢁꢀ65535ꢀ
EST_Object_Typeꢀ
Objectꢀtypeꢀparameterꢀ
EST_Indexꢀ
Indexꢀparameterꢀ
EST_Routeꢀ
Routeꢀparameterꢀ
0ꢀꢁꢀ255ꢀ
EST_Priorityꢀ
EST_Chanꢀ
Priꢀparameterꢀ
Chanꢀparameterꢀ
0ꢀꢁꢀ4ꢀ(seeꢀnoteꢀbelow)ꢀꢀ
0ꢀꢁꢀ255ꢀ
EST_Msg_Indexꢀ
EST_Accountꢀ
MsgIndexꢀparameterꢀ
Accountꢀparameterꢀ
0ꢀꢁꢀ65535ꢀ
0ꢀꢁꢀ255ꢀ
EST_ConfCLꢀ
ConfCLꢀparameterꢀ
0ꢀꢁꢀ65535ꢀ
EST_Panel_Mask_1ꢀ
EST_Panel_Mask_2ꢀ
EST_Panel_Mask_3ꢀ
EST_Panel_Mask_4ꢀ
EST_Panel_Mask_5ꢀ
EST_Panel_Mask_6ꢀ
EST_Panel_Mask_7ꢀ
EST_Panel_Mask_8ꢀ
PanelMask(1)ꢀparameterꢀ(LSB)ꢀ
PanelMask(2)ꢀparameterꢀ
PanelMask(3)ꢀparameterꢀ
PanelMask(4)ꢀparameterꢀ
PanelMask(5)ꢀparameterꢀ
PanelMask(6)ꢀparameterꢀ
PanelMask(7)ꢀparameterꢀ
PanelMask(8)ꢀparameterꢀ(MSB)ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
0ꢀꢁꢀ255ꢀ
Data_Array_Low_Scale*ꢀ ScalingꢀzeroꢀinꢀDataꢀArrayꢀ
ꢁ32767ꢀtoꢀ32767,ꢀ0ꢀ
Data_Array_High_Scale*ꢀ ScalingꢀmaxꢀinꢀDataꢀArrayꢀ
ꢁ32767ꢀtoꢀ32767,ꢀ100ꢀ
Node_Low_Scale*ꢀ
Node_High_Scale*ꢀ
ScalingꢀzeroꢀinꢀConnectedꢀNodeꢀ ꢁ32767ꢀtoꢀ32767,ꢀ0ꢀ
ScalingꢀmaxꢀinꢀConnectedꢀNodeꢀ ꢁ32767ꢀtoꢀ32767,ꢀ100ꢀ
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀ
3ꢀWRBCꢀisꢀnotꢀrecommended,ꢀasꢀstartupꢀvaluesꢀmayꢀbeꢀinvalidꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 8 of 21
ꢀ
Column Title
EST_Alarm_DA*ꢀ
Function
DataꢀArrayꢀtoꢀstoreꢀAlarmꢀstate4ꢀ
DataꢀArrayꢀtoꢀstoreꢀTroubleꢀ
state4ꢀ
Legal Values
EST_Trouble_DA*ꢀ
DataꢀArrayꢀtoꢀstoreꢀꢀSupervisoryꢀ
EST_Supervisory_DA*ꢀ
EST_Monitor_DA*ꢀ
state4ꢀ
DataꢀArrayꢀtoꢀstoreꢀMonitorꢀstate4ꢀ
DataꢀArrayꢀtoꢀstoreꢀstateꢀotherꢀ
thanꢀAlarm,ꢀTrouble,ꢀSupervisoryꢀ
orꢀMonitor4ꢀ
DataꢀArrayꢀtoꢀstoreꢀtheꢀrawꢀvalueꢀ
ofꢀtheꢀactiveꢀbit.ꢀ
EST_Others_DA*ꢀ
EST_Active_DAꢀ
OneꢀofꢀtheꢀDataꢀArrayꢀNamesꢀ
declaredꢀinꢀDataꢀArraysꢀsectionꢀ
Relayꢀconfirmationꢀstate.ꢀꢀReferꢀ
toꢀAppendixꢀA.5ꢀforꢀmoreꢀ
information.ꢀ
EST_Relay_Conf_DAꢀ
DataꢀArrayꢀtoꢀholdꢀTypesꢀ
category.ꢀꢀReferꢀtoꢀAppendixꢀ
A.5.2ꢀ
EST_Types_DAꢀ
UpdateꢀtheꢀdefaultꢀTypesꢀlistꢀorꢀ
referꢀtoꢀnewꢀlist.ꢀꢀRequiresꢀꢀ
'EST_Types_DA'ꢀparameterꢀtoꢀ
beꢀdefined.ꢀꢀReferꢀtoꢀAppendixꢀ
A.5.3ꢀ
EST_Types_Updateꢀ
-, yes,ꢀnewꢀlistꢀ
AcknowledgeꢀState.ꢀꢀReferꢀtoꢀ
AppendixꢀA.5.4ꢀ
OneꢀofꢀtheꢀDataꢀArrayꢀNamesꢀ
declaredꢀinꢀDataꢀArraysꢀsectionꢀ
DA_Bit_Nameꢀ
Storeꢀinformationꢀfromꢀparticularꢀ -,ꢀPoint I/O Status,ꢀSensitivity,ꢀ
Reportꢀ DateꢀTimeꢀ
EST_Report_Typeꢀ
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀ
4ꢀReferꢀtoꢀAppendixꢀA.4ꢀandꢀSectionꢀ4.4.4ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 10 of 21
ꢀ
Appendix A. Driver Notes
Appendix A.1.
PanelMasks:
Theꢀ8ꢀPanelMaskꢀparametersꢀcombineꢀtoꢀformꢀaꢀ64ꢁbitꢀfieldꢀinꢀwhichꢀeachꢀbitꢀdenotesꢀanꢀESTꢀpanelꢀ
inꢀ theꢀ network.ꢀ ꢀ Commandsꢀ thatꢀ useꢀ theꢀ PanelMasksꢀ areꢀ executedꢀ byꢀ eachꢀ panelꢀ forꢀ whichꢀ theꢀ
correspondingꢀ bitꢀ isꢀ set.ꢀ ꢀ Theꢀ Mapꢀ Descriptorꢀ needꢀ onlyꢀ defineꢀ nonꢁzeroꢀ bytesꢀ inꢀ theꢀ PanelMask.ꢀꢀ
TypicallyꢀthisꢀwillꢀbeꢀEST_Panel_Mask_1ꢀwithꢀaꢀvalueꢀofꢀ1.ꢀ
ꢀ
Appendix A.2.
Setting up Multiple Parameters
TheꢀmultipleꢀparametersꢀrequiredꢀbyꢀaꢀcommandꢀmustꢀbeꢀstoredꢀinꢀconsecutiveꢀlocationsꢀinꢀtheꢀDataꢀ
ArrayꢀspecifiedꢀbyꢀtheꢀMapꢀDescriptor,ꢀstartingꢀatꢀtheꢀspecifiedꢀData_Array_Offset.ꢀꢀAllꢀparametersꢀ
mustꢀbeꢀsetꢀupꢀbeforeꢀtheꢀESTꢀcommandꢀisꢀexecuted.ꢀꢀThisꢀisꢀdoneꢀusingꢀaꢀBlockꢀWriteꢀ(ifꢀsupportedꢀ
byꢀtheꢀprotocolꢀoriginatingꢀtheꢀdata)ꢀ–ꢀallꢀparametersꢀareꢀsetꢀupꢀinꢀaꢀsingleꢀwriteꢀoperation,ꢀandꢀtheꢀ
ESTꢀcommandꢀisꢀtriggeredꢀwithꢀallꢀvaluesꢀinꢀplace.ꢀ
ꢀ
Appendix A.3.
Priority:
TheꢀwriteꢀpriorityꢀhasꢀtheꢀpossibleꢀvaluesꢀofꢀSet,ꢀLatch,ꢀLow,ꢀMedium,ꢀandꢀHigh.ꢀꢀTheseꢀareꢀencodedꢀ
asꢀ00h,ꢀ01h,ꢀ02h,ꢀ03hꢀandꢀ04hꢀrespectively.ꢀ
ꢀ
Appendix A.4.
Report and Delta Service:
Theꢀ ESTꢀ ECP3ꢀ Reportꢀ andꢀ Deltaꢀ servicesꢀ reportꢀ pointꢀ statusꢀ slightlyꢀ differently.ꢀ Theꢀ FieldServerꢀ
EST3ꢀdriverꢀdealsꢀwithꢀtheseꢀdifferencesꢀasꢀfollows:ꢀ
ꢀ
•ꢀ Report Service (regular polling):
Theꢀfullꢀ16ꢁbitꢀpointꢀstatusꢀisꢀstoredꢀtoꢀtheꢀReadꢀMapꢀDescriptor’sꢀDataꢀArray.ꢀꢀIfꢀoptionalꢀDataꢀ
Arraysꢀareꢀconfigured,ꢀthenꢀtheꢀpointꢀstatusꢀisꢀalsoꢀinterpretedꢀaccordingꢀtoꢀitsꢀAlarm,ꢀTrouble,ꢀ
SupervisoryꢀorꢀMonitorꢀstatusꢀandꢀtheꢀcorrespondingꢀDataꢀArrayꢀisꢀupdated.ꢀꢀSeeꢀAppendixꢀA.5ꢀ
forꢀdetail.ꢀ
•ꢀ Delta Service (unsolicited messages):
DeltaꢀServiceꢀmessagesꢀdoꢀnotꢀprovideꢀtheꢀsameꢀ16ꢁbitꢀstatusꢀvalueꢀasꢀsuppliedꢀbyꢀtheꢀReportꢀ
Service.ꢀꢀForꢀthisꢀreason,ꢀONLYꢀtheꢀoptionalꢀDataꢀArraysꢀwillꢀbeꢀupdatedꢀwhenꢀaꢀDeltaꢀmessageꢀ
isꢀreceived.ꢀDeltaꢀmessagesꢀwillꢀthereforeꢀonlyꢀhaveꢀanꢀeffectꢀwhenꢀoptionalꢀDataꢀArraysꢀhaveꢀ
beenꢀconfigured.ꢀꢀSeeꢀ0ꢀforꢀdetail.ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 12 of 21
ꢀ
Appendix A.5.
Optional Data Arrays
Whenꢀ optionalꢀ parametersꢀ (EST_Alarm_DA,ꢀ EST_Trouble_DA,ꢀ EST_Supervisory_DA,ꢀ orꢀ
EST_Monitor_DA)ꢀareꢀused,ꢀtheꢀdriverꢀautomaticallyꢀseparatesꢀtheꢀAlarmꢀTrouble,ꢀSupervisory,ꢀandꢀ
MonitorꢀbitꢀfromꢀtheꢀincomingꢀESTꢀmessageꢀandꢀplacesꢀtheꢀbit(s)ꢀinꢀtheseꢀDataꢀArraysꢀatꢀtheꢀsameꢀ
offsetꢀasꢀtheꢀincomingꢀmessage.ꢀꢀOtherꢀtypesꢀcanꢀbeꢀstoredꢀinꢀEST_Others_DAꢀDataꢀArray.ꢀꢀOnlyꢀ
oneꢀDataꢀtypeꢀwillꢀbeꢀreportedꢀasꢀactiveꢀatꢀaꢀparticularꢀtime;ꢀi.e.ꢀifꢀAlarmꢀisꢀreportedꢀDriverꢀwillꢀsetꢀ
AlarmꢀbitꢀandꢀresetꢀcorrespondingꢀbitsꢀfromꢀTrouble,ꢀSupervisoryꢀandꢀMonitorꢀDataꢀArrays.ꢀTheꢀDriverꢀ
doesꢀnotꢀcorrelateꢀOtherꢀtypesꢀwithꢀAlarm,ꢀTrouble,ꢀSupervisoryꢀorꢀMonitorꢀtypes.ꢀꢀForꢀdifferentꢀpointꢀ
typesꢀ theꢀ activeꢀ bitꢀ hasꢀ aꢀ differentꢀ meaning.ꢀ ꢀ Ifꢀ theꢀ userꢀ isꢀ interestedꢀ inꢀ theꢀ meaning,ꢀ theꢀ
EST_Supervisory_DAꢀDataꢀArrayꢀshouldꢀbeꢀconfigured.ꢀꢀIfꢀtheꢀuserꢀisꢀinterestedꢀinꢀtheꢀrawꢀvalueꢀofꢀ
theꢀActiveꢀbit,ꢀtheꢀdataꢀarrayꢀEST_Active_DAꢀshouldꢀbeꢀconfigured.ꢀ
Appendix A.5.1.
Relay Confirmation State
TheꢀdriverꢀcanꢀstoreꢀtheꢀrelayꢀconfirmationꢀstateꢀofꢀaꢀpointꢀinꢀaꢀDataꢀArrayꢀunderꢀtheꢀparameterꢀ
EST_Relay_Conf_DAꢀparameter.ꢀꢀꢀ
0ꢀꢁꢀRelayꢀstateꢀisꢀnotꢀconfirmed;ꢀꢀ
1ꢀ–ꢀRelayꢀstateꢀconfirmed.ꢀ
Appendix A.5.2.
EST_Types_DA
Ifꢀ itꢀ isꢀ necessaryꢀ toꢀ overrideꢀ theꢀ defaultꢀ Typesꢀ andꢀ Categoryꢀ listꢀ (Appendixꢀ C.1)ꢀ theꢀ
EST_Types_DAꢀparameterꢀshouldꢀbeꢀused.ꢀ
ꢀ
Example:
ToꢀputꢀHEATꢀtypeꢀintoꢀtheꢀ“Monitor”ꢀcategoryꢀwhereꢀallꢀotherꢀdefaultsꢀremainꢀtheꢀsame,ꢀpreloadꢀ
theꢀdataꢀarrayꢀasꢀfollows:ꢀ
ꢀ
Preloadsꢀ
ꢀ
ꢀ
ꢀ
Data_Array_Nameꢀ
DA_Typesꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,Preload_Data_Indexꢀ
,2ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,Preload_Data_Valueꢀ
,4ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,Lengthꢀ
,1ꢀ
ꢀ
Preload_Data_IndexꢀisꢀtheꢀtypeꢀofꢀdeviceꢀandꢀPreload_Data_Valueꢀholdsꢀtheꢀcategoryꢀforꢀtheꢀ
specifiedꢀdeviceꢀtype.ꢀꢀTheꢀlegalꢀvaluesꢀforꢀPreload_Data_Valueꢀareꢀlistedꢀbelowꢀ
ꢀ
Alarmꢀꢀꢀꢀꢀꢀꢀꢀꢀ
1ꢀ
Supervisoryꢀꢀꢀ 2ꢀ
Troubleꢀꢀꢀꢀꢀꢀꢀ
Monitorꢀꢀꢀꢀꢀꢀꢀ
Othersꢀꢀꢀꢀꢀꢀꢀꢀ
3ꢀ
4ꢀ
5ꢀ
Appendix A.5.3.
EST_Types_Update
Ifꢀthisꢀparameterꢀisꢀnotꢀdefinedꢀorꢀisꢀ“yes”,ꢀtheꢀdriverꢀwillꢀupdateꢀitsꢀinternalꢀdriverꢀlistꢀaccordingꢀ
toꢀtheꢀparametersꢀpreloadedꢀunderꢀEST_Types_DA.ꢀꢀIfꢀtheꢀparameterꢀisꢀsetꢀtoꢀ“NewꢀList”,ꢀtheꢀ
driverꢀwillꢀuseꢀONLYꢀtheꢀparametersꢀdefinedꢀunderꢀEST_Types_DAꢀandꢀwillꢀnotꢀreferenceꢀorꢀ
updateꢀtheꢀdefaultꢀlistꢀatꢀall.ꢀꢀTheꢀdriverꢀwillꢀthereforeꢀnotꢀstoreꢀanyꢀdataꢀforꢀtypesꢀthatꢀdoꢀnotꢀ
haveꢀpreloadedꢀcategories.ꢀ
Appendix A.5.4.
DA_Bit_Name
Theꢀ”Acknowledge5”ꢀstateꢀofꢀaꢀpointꢀisꢀstoredꢀunderꢀthisꢀDataꢀArrayꢀifꢀconfigured.ꢀꢀꢀ
0ꢀ–ꢀAcknowledgedꢀorꢀAcknowledgeꢀnotꢀrequired.ꢀ
1ꢀ –ꢀ Pointꢀ isꢀ notꢀ Acknowledgedꢀ yet.ꢀ ꢀ Toꢀ Acknowledgeꢀ theꢀ pointꢀ changeꢀ theꢀ valueꢀ toꢀ “0”.
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀ
5ꢀTheꢀEST3ꢀpanelꢀisꢀonlyꢀableꢀtoꢀsend/acceptꢀAcknowledgementꢀwhenꢀtheꢀpanelꢀisꢀinꢀProprietaryꢀMode.ꢀꢀ
ContactꢀESTꢀ(EdwardsꢀSystemsꢀTechnology)ꢀforꢀinformationꢀonꢀconfiguringꢀtheꢀpanel.ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 14 of 21
ꢀ
Appendix A.6.
Object Types and Required Parameters
TheꢀtablesꢀbelowꢀlistꢀtheꢀfieldsꢀrequiredꢀforꢀtheꢀMapꢀDescriptorꢀimplementingꢀeachꢀobjectꢀtype.ꢀ
ꢀ
Object Type
Required Parameters
Activate and Restore Commands (01h and 11h)ꢀ
EST_Panel,ꢀEST_Card,ꢀAddress,ꢀEST_Priorityꢀ
EST_Panel,ꢀEST_Card,ꢀAddress,ꢀEST_Priorityꢀ
EST_Indexꢀ
Relayꢀ
Ledꢀ
ServGroupꢀ
GuardPtrlꢀ
ChkInGrpꢀ
AltMessageꢀ
AmpPowerꢀ
AudMsgꢀ
Resetꢀ
PanelSilꢀ
AlarmSilꢀ
Drillꢀ
EST_Index,ꢀEST_Routeꢀ
EST_Indexꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel,ꢀEST_Card,ꢀEST_Priority,ꢀEST_Chanꢀ
EST_Panel,ꢀEST_Card,ꢀEST_Msg_Index,ꢀEST_Priority,ꢀEST_Chanꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel_Mask(1..8)ꢀReferꢀtoꢀAppendixꢀA.1ꢀ
EST_Panel,ꢀEST_Card,ꢀEST_Priority,ꢀEST_Account,ꢀEST_ConfCLꢀ
EST_Indexꢀ
GAInhibitꢀ
Rebootꢀ
Evacuateꢀ
AltSensitivꢀ
MCmsgꢀ
Partitionꢀ
CmdꢀListꢀ
AndGroupꢀ
SetDateꢀ
SetTimeꢀ
EST_Indexꢀ
EST_Indexꢀ
EST_Object_Type.ꢀꢀReferꢀtoꢀAppendixꢀA.7ꢀ
EST_Object_Type.ꢀꢀReferꢀtoꢀAppendixꢀA.7ꢀ
Enable and Disable Commands (02h and 12h)
EST_Panel,ꢀEST_Card,ꢀAddressꢀ
EST_Panel,ꢀEST_Card,ꢀAddressꢀ
EST_Panel,ꢀEST_Card,ꢀAddressꢀ
EST_Indexꢀ
Relayꢀ
Ledꢀ
Inputꢀ
Zoneꢀ
Cardꢀ
EST_Panel,ꢀEST_Cardꢀ
ServGroupꢀ
AndGroupꢀ
Matrixꢀ
EST_Indexꢀ
EST_Indexꢀ
EST_Indexꢀ
TimeCtrlꢀ
GuardPtrlꢀ
ChkInGrpꢀ
AmpPowerꢀ
Partitionꢀ
InstructionꢀTextꢀ
EST_Indexꢀ
EST_Index,ꢀEST_Routeꢀ
EST_Indexꢀ
EST_Panel,ꢀEST_Cardꢀ
EST_Panel,ꢀEST_Card,ꢀAddressꢀ
EST_Panel,ꢀEST_Card,ꢀAddressꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 15 of 21
ꢀ
Appendix A.7.
Set Date and Time To Panel
TheꢀfollowingꢀMapꢀDescriptorsꢀareꢀrequiredꢀtoꢀsetꢀtheꢀDateꢀandꢀTimeꢀofꢀtheꢀESTꢀPanelꢀ
ꢀ
//ꢀFirstꢀpokeꢀmonth(1ꢁ12)ꢀ,day(0ꢁ31)ꢀandꢀ year(yyyy)ꢀatꢀoffsetꢀ1ꢀ,2ꢀandꢀ3ꢀthenꢀpokeꢀ1ꢀatꢀoffsetꢀ0ꢀtoꢀ
issueꢀSetDateꢀcommandꢀ
//ꢀFirstꢀpokeꢀhour(0ꢁ23)ꢀꢀ,min(0ꢁ59)ꢀandꢀsecꢀ(0ꢁ59)ꢀatꢀoffsetꢀ1ꢀ,2ꢀandꢀ3ꢀthenꢀpokeꢀ1ꢀatꢀoffsetꢀ0ꢀtoꢀissueꢀ
SetTimeꢀcommandꢀ
ꢀ
Map_Descriptorsꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Map_Descriptor_Nameꢀꢀ ,Data_Array_Nameꢀꢀ ,Data_Array_Offsetꢀꢀ ,Functionꢀꢀ ,Node_Nameꢀꢀ ,EST_Object_Typeꢀꢀ ,Lengthꢀ
MD_Set_Dateꢀ
MD_Set_Timeꢀ
,DA_Set_Dateꢀꢀꢀꢀꢀꢀ
,DA_Set_Timeꢀꢀꢀꢀꢀꢀ
,0ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,0ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,Wrbxꢀꢀꢀꢀꢀꢀ ,EST_1ꢀꢀꢀꢀꢀꢀ
,Wrbxꢀꢀꢀꢀꢀꢀ ,EST_1ꢀꢀꢀꢀꢀꢀ
,SetDateꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,SetTimeꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ
,1ꢀ
,1ꢀ
ꢀ
ꢀ
TheꢀfollowingꢀMapꢀDescriptorꢀwillꢀenableꢀtheꢀFieldServerꢀtoꢀsynchronizeꢀitsꢀclockꢀwithꢀtheꢀESTꢀpanelꢀ
clockꢀ
Map_Descriptorsꢀ
Map_Descriptor_Nameꢀꢀ ,Data_Array_Nameꢀꢀ ,Data_Array_Offsetꢀꢀ ,Functionꢀꢀ ,Node_Nameꢀꢀ ,EST_Report_Typeꢀꢀ ,Lengthꢀ
MD_SLV_TIMEꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ,DA_TIMEꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ,0ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ,Passiveꢀꢀꢀ ,EST_1ꢀꢀꢀꢀꢀꢀ ,DateꢀTimeꢀꢀꢀꢀꢀꢀꢀꢀ ,6ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 16 of 21
ꢀ
Appendix B. Troubleshooting Tips
Appendix B.1.
Multiple Com Errors
Toꢀsolveꢀmultipleꢀcomꢀerrors,ꢀtryꢀaddingꢀanꢀIC_TimeoutꢀparameterꢀtoꢀtheꢀClientꢀSideꢀconnectionsꢀandꢀ
setꢀitꢀtoꢀ0.5s.ꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 17 of 21
ꢀ
Appendix C. EST3 Data Format:
Appendix C.1.
Input data format
Eachꢀinputꢀdeviceꢀisꢀassociatedꢀwithꢀaꢀ16ꢁbitꢀvalue.ꢀTheꢀcontentsꢀofꢀtheꢀ16ꢀbitsꢀareꢀusedꢀtoꢀgenerateꢀ
statusꢀ typesꢀ asꢀ shownꢀ inꢀ theꢀ tableꢀ below.ꢀ ꢀ Eachꢀ incomingꢀ eventꢀ isꢀ allocatedꢀ toꢀ aꢀ statusꢀ typeꢀ
dependingꢀonꢀitsꢀdeviceꢀtypeꢀasꢀshownꢀinꢀtheꢀtable.ꢀꢀItꢀisꢀpossibleꢀtoꢀoverrideꢀthisꢀdefaultꢀstatusꢀtypeꢀ
allocation.ꢀꢀReferꢀtoꢀAppendixꢀA.5ꢀforꢀmoreꢀinformation.ꢀ
ꢀ
Type
Encode
Value
0ꢀ
Alarm Trouble Supervisory Monitor Others
Smokeꢀ
Pullꢀ
Heatꢀ
Waterflowꢀ
Stageoneꢀ
Zoneꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
1ꢀ
2ꢀ
3ꢀ
4ꢀ
5ꢀ
6ꢀ
7ꢀ
8ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
AlarmVerifyꢀ
PreAlarmꢀ
Securityꢀ
Stationꢀꢀ
Emergencyꢀ
Supervisoryꢀ
Valveꢀ
GateValveꢀ
Tamperꢀ
Temperatureꢀ
Powerꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
9ꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
10ꢀ
11ꢀ
12ꢀ
13ꢀ
14ꢀ
15ꢀ
16ꢀ
17ꢀ
18ꢀ
19ꢀ
20ꢀ
21ꢀ
22ꢀ
23ꢀ
24ꢀ
25ꢀ
26ꢀ
27ꢀ
28ꢀ
29ꢀ
30ꢀ
31ꢀ
32ꢀ
33ꢀ
34ꢀ
35ꢀ
36ꢀ
37ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Signalꢀ
TroubleOpenꢀ
TroubleShortꢀ
LocalTroubleꢀ
MaintAlertꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
DirtyHeadꢀ
DeviceCommꢀ
GroundFaultꢀ
InternalTroubleꢀ
BadTypeꢀꢀ
BadPersonalityꢀ
UnexpectedDeviceꢀ
CommonTroubleꢀ
RelayConfirmationꢀꢀ
Monitorꢀ
LocalMonitorꢀ
Damperꢀ
Fanꢀ
Doorꢀ
Switchꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
ꢀ
ꢀ
FirePhoneꢀ
ꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 18 of 21
ꢀ
Type
Encode
Value
38ꢀ
Alarm Trouble Supervisory Monitor Others
TestEventꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
DeviceCompatabilityFaultꢀ
LogicAndꢀ
39ꢀ
40ꢀ
41ꢀ
42ꢀ
43ꢀ
44ꢀ
45ꢀ
46ꢀ
47ꢀ
48ꢀ
49ꢀ
50ꢀ
64ꢀ
65ꢀ
66ꢀ
67ꢀ
68ꢀ
69ꢀ
70ꢀ
71ꢀ
72ꢀ
73ꢀ
74ꢀ
75ꢀ
127ꢀ
128ꢀ
129ꢀ
130ꢀ
131ꢀ
132ꢀ
133ꢀ
134ꢀ
135ꢀ
136ꢀ
137ꢀ
138ꢀ
139ꢀ
140ꢀ
141ꢀ
142ꢀ
143ꢀ
Y
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
LogicMatrixꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ServiceGroupꢀ
TimeControlꢀ
GuardPatrolꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
CheckInGroupꢀ
Internal use onlyꢀ
Disabledꢀꢀ
Internal use onlyꢀ
InstructionꢀTextꢀꢀ
ObjectꢀRunningꢀ
Audibleꢀꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Visualꢀꢀ
SupervisedOutputꢀꢀ
NonSupervisedOutputꢀꢀ
CommonAlarmPutputꢀꢀ
CommonTroubleOutputꢀꢀ
CommonSupervisoryOutPutꢀꢀ
CommonMonitorOutputꢀꢀ
LEDOutputꢀꢀ
AnalogOutputꢀꢀ
AudioMessageꢀꢀ
Amplifierꢀꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Cardꢀꢀ
SecurityAlarmꢀ
Yꢀ
SecurityTroubleꢀ
SecurityTamperꢀ
SecurityMaintenanceꢀ
SecurityCommunicationFaultꢀ
SecurityDisarmedꢀ
SecurityExitTimerꢀ
SecurityEntryTimerꢀ
SecurityBypassedꢀ
SecurityStayꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
SecurityAwayꢀ
SecurityStayFailꢀ
SecurityAwayFailꢀ
SecurityClosingTroubleꢀ
SecurityNoCloseꢀ
SecurityPartitionUpdateꢀ
Completeꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Spareꢀ
AccessACFailꢀ
AccessLowBatteryꢀ
AccessStrikeFaultꢀ
144ꢀ
145ꢀ
146ꢀ
147ꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 19 of 21
ꢀ
Type
Encode
Value
148ꢀ
149ꢀ
150ꢀ
151ꢀ
Alarm Trouble Supervisory Monitor Others
AccessReaderFaultꢀ
AccessInternalFaultꢀ
AccessCommunicationFaultꢀ
CmdListꢀ
Yꢀ
Yꢀ
Yꢀ
Yꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Appendix C.2.
Output data format
Eachꢀ outputꢀdeviceꢀisꢀ associatedꢀ withꢀaꢀ16ꢁbitꢀ value.ꢀThisꢀvalueꢀconsistsꢀofꢀtwoꢀbyteꢀfields,ꢀtheꢀ
deviceꢀtypeꢀ(LSB)ꢀandꢀtheꢀdeviceꢀstateꢀ(MSB).ꢀ
ꢀ
FieldServer Data Array Object (16-bit)
Attributeꢀ(8ꢁbit)ꢀ
Commandꢀ(8ꢁbit)ꢀ
ꢀ
ꢀ
Theseꢀ valuesꢀ areꢀ providedꢀ byꢀ theꢀ ESTꢀ panelꢀ andꢀ areꢀ describedꢀ inꢀ theꢀ EST3ꢀ ECPꢀ protocolꢀ
specificationꢀasꢀfollows.ꢀꢀTheseꢀvaluesꢀwillꢀbeꢀputꢀinꢀtheꢀCommandꢀfield.ꢀ
Command
Activateꢀ/ꢀAwayꢀ
Encode Value
01hꢀ
Enableꢀ
02hꢀ
Restoreꢀ/ꢀDisarmꢀ
Disableꢀ
11hꢀ
12hꢀ
ꢀ
TheꢀattributeꢀbyteꢀmustꢀbeꢀsetꢀforꢀwritesꢀtoꢀRelayꢀandꢀLEDꢀoutputs.ꢀForꢀRelays,ꢀtheꢀattributeꢀvaluesꢀ
are:ꢀ
ꢀ
Attribute (Relay)
Encode Value
Enableꢀ
Activateꢀ
Restoreꢀ
Disableꢀ
2hꢀ
101hꢀ
11hꢀ
12hꢀ
ꢀ
ꢀ
ForꢀLED’s,ꢀtheꢀattributeꢀvaluesꢀare:ꢀ
Attribute (LED)
Encode Value
101hꢀ
201hꢀ
301hꢀ
12hꢀ
Onꢀ
SlowꢀFlashꢀ
FastꢀFlashꢀ
Disableꢀ
Enableꢀ
Offꢀ
2hꢀ
1hꢀ
ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 20 of 21
ꢀ
Appendix D. EST3 ECP Connection Statistics:
TheꢀEST3ꢀECPꢀprotocolꢀhasꢀtwoꢀdistinctꢀlevels:ꢀ
•ꢀ Aꢀ pollꢁresponseꢀ connectionꢀ isꢀ maintainedꢀ byꢀ theꢀ ESTꢀ panelꢀ actingꢀ asꢀ theꢀ master.ꢀ Theꢀ bytesꢀ
transferredꢀ inꢀ thisꢀ processꢀ areꢀ displayedꢀ onꢀ theꢀ FieldServerꢀ asꢀ SCADAꢀ bytesꢀ transmittedꢀ andꢀ
received.ꢀ
•ꢀ TheꢀFieldServerꢀ actsꢀasꢀaꢀclientꢀ byꢀ insertingꢀrequestsꢀintoꢀitsꢀresponseꢀmessages;ꢀtheꢀ ESTꢀpanelꢀ
thenꢀinsertsꢀtheꢀrequestedꢀdataꢀintoꢀitsꢀsubsequentꢀpollingꢀmessages.ꢀTheꢀbytesꢀtransferredꢀinꢀthisꢀ
processꢀareꢀdisplayedꢀonꢀtheꢀFieldServerꢀasꢀPLCꢀbytesꢀtransmittedꢀandꢀreceived.ꢀ
ꢀ
TheꢀfollowingꢀstatisticsꢀareꢀavailableꢀonꢀtheꢀDriverꢀAspectsꢀscreenꢀwhenꢀviewingꢀConnectionꢀDetailsꢀ
(selectꢀ theꢀ ESTꢀ Connectionꢀ inꢀ Connectionꢀ Overview,ꢀ andꢀ pressꢀ spaceꢀ repeatedlyꢀ toꢀ pageꢀ toꢀ thisꢀ
screen):ꢀ
ꢀ
Statistic Name
DLLꢀRxꢀCharꢀꢀꢀꢀꢀꢀ
DLLꢀRxꢀMsgꢀꢀꢀꢀꢀꢀꢀ
DLLꢀTxꢀCharꢀꢀꢀꢀꢀꢀ
DLLꢀTxꢀMsgꢀꢀꢀꢀꢀꢀꢀ
DLLꢀTimeoutsꢀꢀꢀꢀꢀ
DLLꢀICꢀTimeoutsꢀꢀ
DLLꢀStreamingꢀꢀꢀꢀ
DLLꢀBadꢀRepliesꢀꢀ
DLLꢀLinkꢀControlꢀ
GatewayꢀTypeꢀꢀꢀꢀꢀ
DataꢀRxꢀCharꢀꢀ
DataꢀRxꢀMsgꢀꢀꢀ
DataꢀTxꢀCharꢀꢀ
Description
DataꢀLinkꢀLayerꢀBytesꢀReceived
DataꢀLinkꢀLayerꢀMessagesꢀReceived
DataꢀLinkꢀLayerꢀBytesꢀTransmitted
DataꢀLinkꢀLayerꢀMessagesꢀTransmitted
DataꢀLinkꢀLayerꢀTimeouts
DataꢀLinkꢀLayerꢀInterꢁCharacterꢀTimeouts
DataꢀLinkꢀLayerꢀStreamingꢀErrors
DataꢀLinkꢀLayerꢀBadꢀReplies
DataꢀLinkꢀLayerꢀLinkꢀControlꢀEvents
ECPꢀGatewayꢀTypeꢀI/II/III
DataꢀBytesꢀReceived
DataꢀMessagesꢀReceived
DataꢀBytesꢀTransmitted
DataꢀTxꢀMsgꢀꢀꢀ
ConnꢀRxꢀCharꢀꢀ
ConnꢀRxꢀMsgꢀꢀꢀ
ConnꢀTxꢀCharꢀꢀ
ConnꢀTxꢀMsgꢀꢀꢀ
DeltaꢀRxꢀCharꢀ
DeltaꢀRxꢀMsgꢀꢀ
DataꢀMessagesꢀTransmitted
TotalꢀBytesꢀReceivedꢀonꢀConnection
TotalꢀMessagesꢀReceivedꢀonꢀConnection
TotalꢀBytesꢀTransmittedꢀonꢀConnection
TotalꢀMessagesꢀTransmittedꢀonꢀConnection
DeltaꢀMessageꢀBytesꢀReceived
DeltaꢀMessagesꢀReceived
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
FS-8700-39 EST3 Driver Manual
Page 21 of 21
ꢀ
Appendix E. Driver Error Messages
Error Message
Description and Action Required
ThisꢀmessageꢀwillꢀbeꢀdisplayedꢀonceꢀifꢀanyꢀMapꢀDescriptorꢀinꢀaꢀconfigurationꢀ
fileꢀhasꢀanꢀoddꢀlength.ꢀꢀOldꢀEST3ꢀPanelsꢀ(beforeꢀ2002)ꢀsimplyꢀdoꢀnotꢀ
communicateꢀifꢀlengthꢀisꢀodd.ꢀ
ThisꢀmessageꢀcanꢀbeꢀignoredꢀifꢀitꢀisꢀnewꢀEST3ꢀpanel.ꢀꢀButꢀifꢀitꢀisꢀoldꢀorꢀ
unknown,ꢀtryꢀmakingꢀMapꢀDescriptorꢀhavingꢀevenꢀlengthꢀbeforeꢀcontactingꢀ
technicalꢀsupport.ꢀ
EST3:#01ꢀFYI.ꢀForꢀanꢀ
OldꢀEST3ꢀPanel,ꢀReadꢀ
MDꢀlengthꢀmustꢀbeꢀeven.ꢀ
EST3:#02ꢀErr.ꢀReadꢀMDꢀ
lengthꢀmustꢀ>ꢀ0ꢀandꢀ<=ꢀ
%dꢀ
Numbersꢀofꢀaddressesꢀtoꢀbeꢀreadꢀperꢀrequestꢀareꢀlimited.ꢀ
EditꢀconfigurationꢀfileꢀtoꢀsetꢀMapꢀDescriptorꢀlengthꢀwithinꢀspecifiedꢀrange.6ꢀ
EST3:#03ꢀErr.ꢀWriteꢀMDꢀ
mustꢀhaveꢀlengthꢀ=ꢀ1ꢀ
OneꢀMapꢀDescriptorꢀcanꢀwriteꢀonlyꢀ1ꢀvalue.ꢀꢀChangeꢀlengthꢀtoꢀ16.ꢀ
EST3:ꢀ#04ꢀUnknownꢀ
EscapeꢀSequenceꢀ1Bꢀ
%02Xꢀconsideredꢀasꢀ
%02Xꢀ
ThisꢀmessageꢀisꢀprintedꢀifꢀtheꢀFieldServerꢀreceivesꢀsequencesꢀthatꢀareꢀnotꢀ
specified.ꢀꢀSpecifiedꢀsequencesꢀareꢀ1Bꢀ82,ꢀ1Bꢀ8Dꢀandꢀ1Bꢀ9B.ꢀꢀThisꢀmessageꢀ
isꢀforꢀinformationꢀonlyꢀandꢀcanꢀbeꢀignoredꢀunlessꢀtheꢀdataꢀstoredꢀbyꢀtheꢀ
FieldServerꢀisꢀinvalidꢀinꢀwhichꢀcase,ꢀcallꢀTechꢀsupport.ꢀ
ꢀ
ꢀ
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ ꢀꢀꢀꢀꢀꢀꢀ
6ꢀDownloadꢀtheꢀconfigurationꢀfile,ꢀmakeꢀtheꢀnecessaryꢀchanges,ꢀuploadꢀtoꢀtheꢀFieldServerꢀandꢀcycleꢀ
powerꢀtoꢀtheꢀFieldServerꢀforꢀtheꢀchangesꢀtoꢀtakeꢀeffect.ꢀ
FieldServer Technologiesꢀ1991ꢀTarobꢀCourtꢀMilpitas,ꢀCaliforniaꢀ95035ꢀUSAꢀꢀꢀWeb:ꢀwww.fieldserver.comꢀ
|